HORN LHD6001+ Скачать руководство пользователя страница 1

Содержание LHD6001+

Страница 1: ...LHD6001 ...

Страница 2: ......

Страница 3: ...INSTALLATION MANUAL Hybrid alarm system ...

Страница 4: ...te Operation and indication Telephone Operation Installation Programming Appendix Operation 1 3 11 15 38 CONTENT General 11 11 11 11 11 AC 12 12 13 Siren output 13 13 13 13 14 14 15 38 39 39 40 41 41 Attention Basic Requirement Installation of control panel Tamper switch connection power connection Backup power connection Installation of keypad PGM Output AUX power output Anti Tamper switch Loop i...

Страница 5: ...led in and confirmed by the installer or the installation company Installer Installation Company Installation Date Tel of Installation Company of Installation Company Center Stations Address Tel of Center Stations 1 Tel of Center Stations 2 The components of the product are packed in a box as followed Open the box and check it carefully If finding deficiency please fetch the provider in time No 1 ...

Страница 6: ...0V AC 14V F5 F4 1 A 1A F6 2A ARM E A R T H POWER Use Default 220V 天线 315mA 红色 红色 绿色 绿色 GPRS TCP IP RELAY 12V BELL BELL 2 N O detector AUX POWER Transformer Power AUX POWER Controlled element Wireless module GENERAL ...

Страница 7: ... 1 2 3 Continuous sound means alarming 1 sound reminds of successful disarm 2 sounds remind of successful arm 4 4 sounds remind of disarm arm failure Bell signification Term Definition Oper 3 The LED of the zones except those with 24hours zone type will be off when they are disarmed one by one or bypassed or under disarm status And the LED will be on to show the zones availability Server connected...

Страница 8: ... 23 24 25 system reset via hardware or programming optional Main features and functions 4 Oper 24 hour zone No matter armed or disarmed it is in effective detecting status It is usually used in fire alarm plunder alarm and other emergent alarm which can be cancelled only by password holder Center Monitoring Station CMS Alarm message will be sent to CMS via telephone line which can take action acco...

Страница 9: ...Gas zone Tamper zone Duress zone 24h Zone Non alarm zone Note 1 Key zone is used just for arm or disarm and will not alarm after it triggered Note 1 2 Keypad will trigger Zone 51 54 Tamper Alarm if it stops working without cancellation When use a walling board shall not use the 4 keypad th 5 Ineffective Ineffective Ineffective Effective Effective Effective Effective Effective Effective Effective E...

Страница 10: ...shorten the distance between the receiver and transmitter Oper Transmitter B Transmitter A Transmitter B 2 Force Arm If the zones except 24h zones are triggered which are set type1 by command 47 the panel will still arm by pressing the button on remote controller one more time after the first arm failure After this operation the triggering zones will be automatically bypassed After restore the zon...

Страница 11: ......

Страница 12: ...programming code Duress code Programming Arm Disarm All Arm Disarm partly 8 Oper Siren Signification Note The duress code has the same right with master code and user s code Keypad operation Arm or disarm all zones The user will arm all the zones by pressing the ARM AWAY or ARM STAY button on the keypad or by using the user s code which has the right to arm all the zones The arm all zones action c...

Страница 13: ... 3 Force arm some zones Input user s code then 1 with to force arm the system if previous arm action invalid Then the zones under the control right of the input code will be force armed For example if user s code 5678 has the right to control zone 3 5 and 8 Press disarm button input user s code 5678 confimed with then zone 3 5 and 8 will be disarmed After installed correctly the keypad can be canc...

Страница 14: ...e as following User dials the number the system picks up the phone press input password X Press Hang up X 1 arm away X 2 arm stay X 3 disarm X 6 siren off X 7 siren on The siren will keep on for the time same with what set by command 29 X 0 hangs up Dialing the master phone for more than ringing attempts set The system will answer automatically and announce the user with a sound Di Then user press...

Страница 15: ... fails If the user has any problem while using call our company for help Before installation please read the requirements as below 220VAC input 15V 2A output 50Hz transformer Connect 14V output port of transformer to 14VAC IN of the control panel two green wires Transformer secondary supplies power only for the control panel Can not share with other units Total current of the detector and the cont...

Страница 16: ...15 minutes and check all the time under AC power disconnected situation Note If low voltage is still indicated on the keypad after 24 hours charging the battery might be out of use Keypad installation TERMIALS KDATA GND V_KEY Terminals V_KEY GND GND Power KDATA Power input terminal on the keypad Data line for communication between keypad and the master controller Connection between the wiring boar...

Страница 17: ...the fuse b remove the short or overload condition then replace the fuse Do not substitute a higher rated fuse to with 1A current urned ed Loop input This panel can be connected to 8 wired zones with NO or NC detectors by using a 2 2k resistor which will be packed with panel Connection diagram for Nc detector Connection diagram for NO detector NC detector Zone GND 2 2KΩ EOL NO detector Zone GND 2 2...

Страница 18: ...hone line is restored indicator will be off Telephone line connection AC power connection Check line connection again ensuring all lines are connected correctly Switch on AC power power indicator on the keypad will be on buzzer will beep twice back light of the keypad alarm indicator and Keypad begins initialization and then buzzer continuously beeps till the initiation finished Telephone line Tel...

Страница 19: ... checking times 15 X X 3 21 21 21 21 05Means500ms Edituser sID Edituser scode 20 X X 21 X YYYY 0808 22 22 Calling period Period interval 17 XX 18 XX 19 XX YY X 1 9 Count circle XX 01 24 Unit 15minutes XX 02 Means 30 minutes X 1 16 X 22 EditInstallercode 22 XXXX 1234 22 23 X X 6 PROGRAMMING 15 Note 1 Buzzer will beep once any button is pressed and the back light will be on which will be off if ther...

Страница 20: ...eries number of GSM device YY message option Lasting time of siren working XX 00 30 unit 1minute Working time 0 30 minutes XX 10 10s Exit delay time adjustment XXX 000 300 Time delay 0 300 seconds XXX 100 100s Entry delay time adjustment XXX 000 300 Time delay 0 300 seconds XX 040 40s 22 25 X 3 X 3 9 34 X Ring attempts thru a free of charge of telephone line Attempts to send the same message to a ...

Страница 21: ...eriod of sending 1st message Setting period of sending 1st message to CMS X after the panel powers on or recovers X 1 2 YY 01 10 99 YY 02 30minutes for CMS1 CMS2 Period of sending messages to CMS1 CMS2 Sending a test report every Y hours to CMS X X 1 2 YY 00 11 80 84 YY 00 Don t send Limit count of input wrong password before the keypad is unavailable XX 00 means the keypad is always available X 0...

Страница 22: ...ssword Null Attribute of PPCE X 0 4 X 0 PPCE is not available X 1 PPCE is used in programming X 2 PPCE is used in disarm arm X 3 PPCE is used in disarm arm and programming X 4 PPCE is used in disarm arm and programming It will not be available after setting moment PSTN GPRS TCP cooperation XXX means Sequence trying sending messages X 1 PSTN X 2 GPRS X 3 TCP Y 1 1 way Y 2 2 ways Y 3 3 ways Z 0 turn...

Страница 23: ...ing Not for phone numbers password user s address wireless detectors keyfobs and the type of wireless detectors Keypad log out 1 Telephone 1 to 4 should not be set with personal phone numbers in case extra charge cost 2 When Panic alarm happened the system will not call telephone 5 and 6 but CMS1 AND CMS2 telephone 7 and telephone 8 It is not suggested to set telephone 7 and telephone 8 with perso...

Страница 24: ...ontent For example 05 the corresponding zone bypass and alarm beat Zone Bypass report at this time and alarm information additional information is not sent Set Dual CMS MODE Command 13X Note when Mode 2 Double CMS set to receive message is set command 132 the CMS 2 is invalid Regular reporting can be set by command 51 see Interval between test reports for more information Note It iwll be activated...

Страница 25: ...lable by remote operation Note 1 After this setting the system will self check the siren of the system 2 minutes later after initialization It will report the trouble of the siren by CID code 320 2 Siren trouble will not be displayed in keypad but only with beeps indication Edit user s password Command 21XYYYY If user s password is 8889 then the duress will be 8880 and it will be 9990 when user s ...

Страница 26: ...lable except active zones When disarmed fire zone gas zone panic zones anti tamper zones duress zones and 24 hours zones are available It will not send a alarm message only arm or disarm control signal when key zones are triggered This can be set via command 45 When the user use this keyzone to disarm or arm this system the siren will sound when there is no keypad connected and not sound when keyp...

Страница 27: ...red there will be reply outputting with the time set by command 43XX 00 01 16 17 18 31 34 51 56 61 76 77 78 80 81 82 83 84 85 86 87 88 91 92 93 94 95 96 97 98 99 Relay Relay Relay AC lose low battery GPRS disconnected TCP exit entry zone alarm active zone alarm panic alarm fire zone alarm gas zone alarm anti tamper alarm duress alarm 24h perimeter zone alarm disconnected Perimeter zone alarm descr...

Страница 28: ...For example when Y is set as 4 and Z is 0 it can be only arm stayed or disarmed And it couldn t be disarmed when it is alarming or entry delaying when keyzone is triggered They system will be in arm stay after keyzone restored When there is alarming or zones are triggered which are not allowed to be armed the system will not be armed and and the keyzones couldn t be used to force arm this system W...

Страница 29: ... 81 82 83 84 Interval to report 1hour under arm status 2hour under arm status s 4hour under arm status s 12hour under arm status 24hour under arm status If it is set CMS Mode 2 command 132 the setting for CMS2 will be invalid Y 01 02 03 04 05 06 Period 15m 30m 1h 2h 4h 6h Parameter 07 08 09 10 99 Period 8h 12h 16h 24h s me with testing report sendingperiod a When Mode 2 Double CMS set to receive m...

Страница 30: ...ser Keyswitch arm disarm user NO Zone No Armed STAY Keyswitch armed STAY user NO Zone No Bell Disable Zone bypass All zones bypass or cancel bypass when the Zone NO 99 Periodic test report ADEMCO Contact ID The following table defines the user Codes used in Arming disarming Code Event Operation using keypad without user code such as arm away from disarm to arm stay Disarming by user with master co...

Страница 31: ...as follows 1 Intruders may get access to unprotected openings may not alert people if they are installed in an improper position 2 The system will disable without power 3 Alarm warning devices such as bells may not alert people if they are installed in an improper position 4 Telephone line used to transmit alarm signals may be out of service for any reason or can not perform communication normally...

Страница 32: ...arm information after having been picked up User ignores the panel after picking up When you press the key 5 the panel will speak Alarm information 3 for disarm information 1 for arm information 4 for listening to scene of panel 0 for Stopping dialing and hanging up The command 0 1 2 and 3 can stop the panel s dialing When the panel detects a new alarm event it will dial again Panel s telephone li...

Страница 33: ...ype Zone NO Zone NO Wireless zones Wireless zones Panel Keypad Dimension Dimension voltage voltage Stand by current Stand by current Working temperature Working temperature Zone trigger time 274mm 264mm 86mm AC 220V 80mA 10 C 55 C 500ms 165mm 121mm 28mm 2V 50mA 10 C 55 C AC 1 Specification 29 APPENDIX 1 2 3 4 5 6 7 8 ...

Страница 34: ......

Страница 35: ......

Страница 36: ......