19
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces
Trouble shooting guide for Techrite ignition pack
Warning:
This is a 240VAC module. All connections to the module are 240V (except ignition cable and flame sense).
Ensure power is switched off before checking any connection or replacing any components.
There is a red LED (light) and a green LED (light) on the blue ignition box. If a fault occurs the sequence of the flashing
red light indicates the fault. These codes are listed below.
The green light indicated the ignition box is sensing the flame
Atmospheric Models
Flash
Code
Meaning
Possible
Cause
(Red LED)
Long short
1
0
Running
OK
Appliance running correctly
(Green LED will be on)
2 1
Maximum retries
Check spark electrode for damage
exceeded
and clean if necessary. Check
Unit has tried to light electrode connection. Check
and not detected flame. solenoid connections. Check gas
supply.
2 2
Flame fail lockout.
Check electrode, lead
Unit has detected loss
and connection. Check gas supply.
of flame. It has tried
re-ignition and locked out
Fan Forced Models
The codes above still apply plus the codes below.
1 2
Pressure switch off
Check if fan starts. If fan
Pressure switch contacts. starts OK, check pressure switch.
have not closed.
1 3
Pressure switch on
Pressure switch is faulty
Pressure switch contacts
and is stuck on, or fan has
have not opened after not turned off.
last heat cycle.
3 1
Pressure switch fail
Check combustion fan. Check
Unit has started and pressure switch and connections.
during heat cycle the Check flue for obstructions.
pressure switch has
opened.