pH Electrode

9681S-10D Instruction Manual

This manual describes the operation of the pH electrode,
9681S-10D. Be sure to read this manual carefully, before
using the electrode.
This is the English translation of an original Japanese
document.

Conformable standards

Authorised representative in EU

HORIBA UK Limited
2 Dalston Gardens, Stanmore, Middx HA7 1BQ, UK

Caution on use

Safety Precautions

Points of concern

Do not shock the electrode.

Do not measure chapped or cracked electrode. Replace
such electrode with a new one.

Do not allow the connector to come in contact with water
or unclean hands.  If not, accurate measurement cannot
be performed.

Always use the 3.33 mol/L-KCl solution (model 300)
internal solution for reference electrode.

If the responsive glass membrane or liquid junction is
very dirty and cannot be washed clean using pure water
(or deionized water), clean it depending on dirt
condition. (Refer to "Maintenance" (page 3).)

Do not use this electrode at acidic or alkaline
concentrations above 0.1 mol/L. Using the electrode
under these conditions may harm performance and
shorten the life of the electrode. 

Do not measure the solutions which contain hydrofluoric
acid, which may corrode the glass.

Do not suddenly immerse the electrode in samples
where the temperature variation is 50

C or more.

Silver chloride can be detected inside the responsive
glass membrane. However, it will not cause any
performance problem.

Do not use the electrode in any place where usable
temperature is out of the specified range.

White crystal can adhere to the internal solution filler
port or protective cap after storage of the electrode.
However, it will not cause any performance problem.

If the sleeve of the liquid junction is stuck with
crystallized internal solution, immerse the sleeve in hot
water at 30

C to 40

C to dissolve the crystal, and then

This equipment conforms to the following standards:

RoHS:

EN50581
9. Monitoring and control instruments

CAUTION

Chemical solution

The internal solution in the electrode uses potassium chloride 
(3.33 mol/L-KCI). If the internal material comes in contact with the 
hands or skin, wash immediately with water. If the internal solution 
comes in contact with the eyes, flush with a large amount of 
running water, then seek medical advice.

Glass fragments

Glass fragments can cause injury.
The outer tube and tip of the electrode are made from glass.
Be careful not to break them.

move the sleeve carefully to check the internal solution
discharges. (Use of the ultrasonic cleaner is effective.)

Push down the sleeve lightly. If it is pushed down
strongly, potential difference between liquid may be
greater and may cause error of measurement.

Packaged contents

Specifications and parts description

Part name

Specifications

Name

Q’ty

Electrode

 

9681S-10D

1 pc

Instruction manual (this book) 1 booklet

Temp. connector

Lead

Electrode connector

Connector cover

Protective cap

Cap

Responsive glass

membrane

Internal solution 

filler port (Slide cap)

Liquid

junction

Stem

Electrode model

9681S-10D

Measurement range

pH 0 to 14

Usable temperature range

0

C to 60

C

Storage temperature range

0

C to 50

C

Internal electrode

Silver/silver chloride

Reference electrode internal 
solution

3.33 mol/L-KCl solution (model 300)

Liquid junction

Sleeve

Liquid junction material

Glass

Wetted material

Glass

Electrode length

151 mm

Ext. diam. of wetted part

12 mm

Liquid junction height

Approximately 26 mm (from the tip of 
electrode)

Lead length

1 m