Cleaning final filter

The 

final filter 

assists in the filtration

process to return clean air to the room.

To remove this filter when it becomes
dirty, open the door on the side of the
cleaner.

Lift out filter (B) and hand wash it in
cold water with mild detergent.

Let filter air dry and reposition it on the
side of the cleaner. Make sure the green
colored side of filter faces outward.
Close door.

Should you want to replace this filter,
ask for 

HOOVER part No. 40110004.

Do not operate cleaner without either
the secondary or final filter in place.

Cleaning secondary filter

Disconnect cleaner from electrical
outlet.

The 

secondary filter (A)

, located behind

the grill in the bottom of bag compart-
ment, protects the motor from dirt parti-
cles.  

If filter becomes dirty, pull off grill and lift
out filter.

Hand wash filter in cold water with mild
detergent, then air dr y.

Reposition dry filter and grill. 

Should you want to replace this filter, ask
for 

HOOVER

part No. 38765019.

Replacing bag door

Reposition bag door by placing tabs on
bottom of door into opening (C).  

Press top of door to snap securely shut.

9

3 - 5

3 - 2

A

B

C

A

C

B

Removing and installing filter
b a g

Grasp filter  bag collar (A) and pull collar
f rom tube (B).

Note: Do not clean out old filter bag and
reuse.  Discard used filter bag.

Hold new filter bag as shown. Align open-
ing in filter bag with (B).  

Push (A) firmly onto (B). 

Tuck in filter bag.

Secondary and final
filters

3 - 6

Reattaching filter door

The filter door is designed with a “break-
away“ feature which allows it to snap
free if it is pushed open too far.
To reattach, align hinges (C) of cover
with slots on sides of filter area.  
Press door back into place.

Check agitator shield

Because your cleaner picks up so well,
we strongly recommend you check for
debris accumulation under the agitator
shield each time you clean the filters.
Removing debris under the shield will
help maintain your cleaner’s excellent
pick up and suction.  Remove debris as
follows:
1. Disconnect cleaner from electrical
outlet.

2. Check for dirt accumulation by
removing bottom plate (Fig. 3-10),
removing agitator (Fig. 3-11), and lifting
agitator shield (Fig. 3-13).
3. Remove any debris and replace
shield, agitator and bottom plate (Figs.
3-13 to 3-15).

3 - 3

3 - 4

Содержание WindTunnel U5465-900

Страница 1: ...dTunnel by HOOVER Congratulations on your purchase This WindTunnel vacuum cleaner takes HOOVER Type Y Allergen Filtration filter bags This product was designed for easy Assembly See page 3 www hoover...

Страница 2: ...ays turn off this appliance before connecting or disconnecting hose Do not use without dust bag or filters in place C h a n ge bag frequently when p i cking up very fine materials such as pow d e r Us...

Страница 3: ...9200 for an automated referral of authorized service outlet locations U S only OR 1 330 499 9499 to speak with a representative in our Consumer Response Center OR Visit us online at www hoover com to...

Страница 4: ...into the 3 notches and the clip as shown Slide hose into B and twist hose to lock it into place Lift hose tube cover C NOTE Hose must be connected as shown for all operations D B C B E A 4 Remove bag...

Страница 5: ...lectrical outlet To turn cleaner ON push switch up To turn cleaner OFF push switch down 1 2 3 4 3 3 5 6 7 8 9 10 11 12 13 13 14 14 15 16 17 18 19 20 21 22 23 24 STEP III Position tools household use P...

Страница 6: ...eed more cleaning attention It is able to sense when larger amounts of dirt particles especially embedded dirt are removed To let you know that the Dirt FINDER fea ture is ready the red light will com...

Страница 7: ...to top When using cleaning tools the agita tor will continue to rotate CAUTION To avoid personal injury or unnecessary wear to carpet and to prevent the cleaner from falling always place it at bottom...

Страница 8: ...eaches the dotted line If more dirt than this accumulates your cleaner will not operate effectively Note All new carpet has loose fibers which can fill the bag quickly while vacuuming If you are using...

Страница 9: ...placing tabs on bottom of door into opening C Press top of door to snap securely shut 9 3 5 3 2 A B C A C B Removing and installing filter bag Grasp filter bag collar A and pull collar from tube B Not...

Страница 10: ...plate as shown in How to replace Replace belt if it is stretched cut or broken What to buy To assure effective operation use only genuine HOOVER belts with your clean er When purchasing a new belt as...

Страница 11: ...place When agitator brushes are worn the agitator should be replaced To check condition of brushes discon nect cleaner from electrical outlet Move edge of a card across bottom plate while turning agit...

Страница 12: ...amage Therefore do not add lubricant to motor bear ings The agitator is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoove...

Страница 13: ...low Clearing blockages Disconnect cleaner from electrical outlet Low suction or pick up may be due to a blockage in the system Refer to the fol lowing steps to check for blockages continuing with eac...

Страница 14: ...the appliance to one of the following authorized warranty service outlets Proof of purchase will be required before service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty S...

Отзывы: