Hoover WindTunnel S3630 Скачать руководство пользователя страница 13

Problem:  Cleaner won’t run

Problem:  Cleaner suction low

Problem: Power nozzle agitator 

brush roll won’t run

Problem:  Nozzle won’t pick up

Possible cause

Possible solution

• Not firmly plugged in. 

• Plug unit in firmly.

• No voltage in wall plug. 

• Check fuse or breaker.

• Blown fuse or tripped breaker. 

Replace fuse/reset breaker.

Possible cause

Possible solution

• Hose power cord not firmly plugged 

in. 

• Plug firmly into receptacle on  

 cleaner base.

• Broken or worn belt. 

• Replace belt.

• Floor surface set to BARE. 

• Set floor surface to RUG.

Possible cause

Possible solution

• Low cleaner suction. 

• See section “Cleaner suction low”.

• Blockage in nozzle connector. 

• Remove blockage

• Agitator brush roll not running. 

• See section “Agitator brush roll  won’t  

 run”

• Agitator brush roll brushes worn. 

Replace brushes.

Possible cause

Possible solution

• Bag full. 

Replace paper bag.

•Blockage in nozzle connector,    

hose or wands. 

• Remove blockage.

• Secondary filter dirty. 

• Clean filter.

• Bag not opened. 

• Open bag by pulling folds.

•Hose not properly connected to   

cleaner 

Ensure hose is properly connected.

4. If you have a 

problem 

If a minor problem occurs, it usually 

can be solved quite easily when the 

cause is found by using the check 

list below. 

nector and remove any blockage.

Familiarize yourself with these home 

maintenance tasks as  proper  use 

and care of your cleaner will ensure 

continued cleaning effectiveness.

4. Make sure power nozzle plug is 

disconnected from hand grip. Then 

2. Plug cleaner in, turn on, and 

check hose end for suction. Remove 

any obstructions.  

3. Remove power nozzle from 

wands and attach wands to hose. 

Check for suction and remove any 

blockages. 

4-1

4-2

A

check for blockage in nozzle connec-

tor (A).  

Push nozzle connector down to low-

est position. Look into nozzle con-

Problem: Powered hand tool 

brush roll won’t turn

Possible cause

Possible solution

• Too much pressure being applied to  

tool. 

• Continue using tool applying light   

pressure.

• Blockage in turbine channel. 

• Remove blockage

• Broken or worn belt. 

• Replace belt.

• Low cleaner suction. 

• Check items under “Cleaner suction  

 low”.

4-3

B

5. Disconnect powered hand tool 

(some models) from hose. Remove 

bottom plate, belt guard and turbine 

as described in Figs. 3-21, 3-22 and 

3-29.

Remove any blockage from turbine 

channel (B).

Replace belt, turbine, brush roll, belt 

guard and bottom plate.

13

Continued 

Содержание WindTunnel S3630

Страница 1: ...n Stairs 8 If You Have a Problem 13 Clearing Blockages 13 Important Safeguards 3 Maintenance Filter Bag 8 Filters 9 Lubrication 12 Power Hand Tool Brush Roll Replacement 11 12 Power Hand Tool Belt Rep...

Страница 2: ...fax 7920 W Tropical Parkway Suite 110 Las Vegas NV 89149 702 645 4320 702 645 7518 fax NEW MEXICO 4770 Montgomery VC NE Suite A 103 Albuquerque NM 87109 505 883 0800 505 883 4970 fax NEW YORK 3312 She...

Страница 3: ...lint hair or anything that may reduce air flow Do not pull or carry by cord use cord as a handle close door on cord or pull cord around sharp edges or corners Do not run appliance over cord Keep cord...

Страница 4: ...ce button OR Call 1 800 944 9200 for an auto mated referral of authorized service outlet locations U S only OR Call 1 330 499 9499 to speak with a rep resentative in the Hoover Consumer Response Cente...

Страница 5: ...eadlight 3 Spring latch locks extension wands together or locks wand to nozzle or tool 4 Wand storage clip place cleaner on end and hook clip onto bottom of cleaner 5 Extension wands used with rug and...

Страница 6: ...to deep clean carpets Hard surface floor cleaning The power nozzle can be used for cleaning hard surface floors such as wood linoleum vinyl asphalt and rubber tile sealed cork concrete and Deluxe powe...

Страница 7: ...such places as dresser drawers upholstered furniture stairs and baseboards F Furniture nozzle may be used for upholstered furniture draperies tap estries mattresses clothing auto mobile interiors and...

Страница 8: ...ne HOOVER Al lergen Filtration Type S disposable filter bags Regular HOOVER Type S dispos able bags also fit your cleaner and will give satisfactory performance To assure that your HOOVER clean 3 Main...

Страница 9: ...zle drives the agitator It has been designed specifically for use in this cleaner and is important for effective operation What to buy There are other belts manufactured that are similar in shape and...

Страница 10: ...en to replace Disconnect cleaner from electri cal outlet When agitator brush roll brushes are worn the brush roll should be replaced To check condition of brushes move edge of a card across bottom pla...

Страница 11: ...ontinued been used in your cleaner to prevent overheating if a large item or clog gets caught in the nozzle or at the opening of the bag When the blockage is not re moved the thermal protector will tr...

Страница 12: ...a long time and is not normally replaced However if the belt is cracked gouged or broken it should be replaced 3 27 3 28 3 29 The belt can be seen through the top of the nozzle or by removing the bot...

Страница 13: ...If you have a problem If a minor problem occurs it usually can be solved quite easily when the cause is found by using the check list below nector and remove any blockage Familiarize yourself with the...

Страница 14: ...ice is rendered 1 Hoover Sales and Service Centers 2 Hoover Authorized Warranty Service Dealers Depots For an automated referral of authorized service outlets in the U S A phone 1 800 944 9200 OR visi...