3
Cleaning the dust container / multi-cyclonic separation unit
This cleaner uses a multicyclonic separation system, unique to hoover. If necessary the
separation unit can be disassembled from the dust container and cleaned.
1. release the dust container by sliding the dust container release button towards the
rear of the cleaner.
[13]
Lift the dust container from the cleaner main body.
2. hold the dust container with one hand and with the other hand rotate the dust con
-
tainer handle anti clockwise to release it from the dust container.
[15]
3.
Remove the multicyclonic separation unit from the dust container by pulling the
handle provided.
[20]
4. If necessary, use a cloth to remove excessive dust from the multi-cyclonic unit sur-
face.
[21]
5. reassemble the multicyclonic separation unit to the dust container and refit the filter
pack in position.
6.
reassemble the dust container handle to the bin container. refit the dust container
to the cleaner.
note:
for stubborn dirt the multi-cyclonic separation unit, or the dust container
can be
washed, but care must be taken to ensure that both are completely dry before use.
important:
For optimum performance, we recommend that the multi-cyclonic separation
system is inspected after each empty.
Removing a blockage from the cleaner
1.
Check if the dust container is full. If so refer to ‘emptying the dust container.
2. If the dust container is empty but suction is still low:
A.
Do the filters need cleaning? If so refer to ‘Cleaning the washable filters’.
B.
Check if there is any other blockage in the system - Use a rod or pole to remove
any blockage from the extension tube or flexible hose.
C.
Check if pre-motor filter is fitted.
d.
Check if the separation unit needs to be cleaned. Refer to ‘Cleaning the separa-
tion unit’
USer CheCKlIST
Should you have a problem with the product, complete this simple user checklist
before calling your local Hoover service.
• Is there a working electricity supply to the cleaner? please check with another
electrical appliance.
• Is the dust container over-filled? please refer to ‘Cleaner maintenance’.
• Is the filter blocked? please refer to ‘Cleaner maintenance’.
• Is the hose or nozzle blocked? please refer to ‘removing a blockage from the
system’.
• has the cleaner overheated? If so, it will take approximately 30 minutes to automati
-
cally reset
IMPORTANT INfORMATION
hoover spares and Consumables
Always replace parts with genuine hoover spares. These are available from your local
hoover dealer or direct from hoover. when ordering parts always quote your model num
-
ber.
Consumables
• hepa / Foam Filter pack:
U64 35601223
Spares
• Carpet and Floor nozzle:
G140 35601226
• Flexible hose:
D132 35601224
• Stretch hose:
D133 35601225
• Grand Turbo nozzle:
J55 35601206
• mini Turbo nozzle:
J56 35601227
• hard Floor Caresse nozzle: G133pC 35601205
hoover Customer helpline Service
Should any faults occur with your cleaner during the first 12 months contact the hoover
Customer helpline on the number below.
tel: 08444 995 599
Email: [email protected]
hoover have a computerised nationwide service network of over 500 engineers who will
quickly respond to your call and guarantee your repair for 12 months.
* Certain models only
rush eVo Im UK.indd 3
5/5/2011 8:47:59 Am