To replace brushes
Press brush firmly to snap into place.
Align posts (C) on both ends of brush
assembly with slots (D) in cleaner hous-
ing.
Make sure that the square post (E) also
aligns with the square hole (F). Turn
brushes slightly until post fits easily into
hole.
Storage
Before storing:
l
Empty solution tank and rinse
thoroughly with clean water.
l
Replace
empty
solution tank and
turn deep cleaner ON. Squeeze
trigger and push deep cleaner for-
ward and back several times to
expel any solution remaining in the
deep cleaner’s system. (Do not use
deep cleaner on wood floors.)
l
Empty recovery tank and rinse
thoroughly with clean water.
Allow brushes and underside of deep
cleaner to air dry thoroughly before
storing deep cleaner on a carpeted or
wood surface.
Do not store deep cleaner with a full
solution tank In place.
Lubrication
The motor Is equipped with bearings
which contain sufficient lubrication for
the life of the motor. The addition of
lubricant could cause damage.
Do not
add lubricant to motor bearings.
Service
To obtain approved HOOVER service
and genuine HOOVER parts, locate the
nearest
Hoover Factory Service Center
or Authorized Hoover Warranty
Service Dealer (Depot)
by:
l
checking the Yellow Pages under
Vacuum Cleaners Household” OR
l
checking the list of Factory Service
Centers provided with this cleaner
OR-
* calling i-800-944-9200 for an
automated referral of authorized
service outlet locations (U.S. only)
OR-
* checking the Service section of The
Hoover Company on-line at
www.hoover.com
Please do not
send your cleaner to The
Hoover Company in North Canton for
service, this will only result in delay.
If further assistance Is needed, contact
The Hoover Company Consumer
Response Center, North Canton, Ohio
44720 Phone: l-330-499-9499.
In Canada, contact Hoover Canada,
Burlington, Ontario
Phone: l-800-263-6376.
Always identify your cleaner by the
complete
model number when request-
ing information or ordering parts. (The
model number appears on the bottom of
the cleaner.)
14
If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the check list below.
Possible cause
Possible solution
l
Not firmly plugged in
l
Plug unit in firmly
l
No voltage In wall plug
l
Check fuse or breaker
Blown fuse/tripped breaker
l
Replace fuse/reset breaker
Possible cause
Possible solution
l
Recovery tank full/automatic
shut off engaged
l
Remove and empty recovery tank
Blockage In tool on end of hose
l
Remove tool and clear blockage
l
Recovery tank lid not on
correctly
Make sure lid is on securely
Possible cause
Possible solution
l
Solution tank not firmly in place
l
Make sure tank is securely locked in
position
l
Solution tank empty
l
Refill tank according to instructions for
surface being cleaned
l
Recovery tank lid not on
correctly
l
Make sure lid is firmly in place
l
Pump needs to be “primed” (when
using tool)
l
See ‘Before using tool” section, p. 11
Possible cause
Possible solution
l
Indicator screen dirty
Remove clear cover over indicator
and clean screen; replace cover
l
Speed selector on OFF
l
Move speed selector to Low or Hi