Hoover Nextra Скачать руководство пользователя страница 3

           

 

 

 

2004

 

 

Error 

Code 

Number of 

Flashes by  

2 LEDs 

Time the 

2 LEDs 

stay OFF 

Possible reason of the Error Warning: 

Error   4 

11 

3 sequential operations by the Anti-flood Contacts of 
the Pressure Switch, due to Mechanically Blocked 
Opened Solenoid Valve or faulty Pressure Switch. 

Error   5 

10 

Faulty NTC Temperature Reading Probe and/or Wiring 
and/or "Core" Board. Ohmic values of NTC Probe are: 
20 Kohm at 25°C – 2.14 Kohm at 85°C.  

Error   6 

Defective "Core" Control Board. 

Error   7 

Main Motor's Rotor is jammed. 

Error   8 

Short or Open Circuited Motor's Tachometric Dynamo 
and/or Wiring. Ohmic values of Tacho's Coil as follows: 
Ohmic Value with Ceset Motor: 42 Ohm 
Ohmic Value with Hoover Motor: 156 Ohm 
Ohmic Value with Sole Motor: 184 Ohm 

Error   9 

Short Circuited Motor's Triac on the "Core" Control 
Board and/or defective "Core" Control Board. 

Error 10 

10 

Faulty Program's Selector and/or Wiring. 

Error   0  

14 

Faulty Wiring and/or defective "Core" Control Board. 

 
Making reference to the above resuming table of the available Error Codes, we like to remind 
the importance of the perfect continuity of the electric wiring and of the related connectors, 
when dealing with electronic controls of the "Core" family. This is both true for the contacts on 
the Control Board then for the corresponding contacts on the controlled peripherals (Program's 
Selector, Display Board, etc.) 
 
A partial oxidation of some connector's contacts on the "Core" Control Board (or on the 
connected peripherals, such as the Program's Selector and the Door Lock Safety Device), 
could generate the displaying of a peripheral related Error Code, even being the involved 
peripheral in perfect conditions. 
 
Therefore, we suggest to carefully check the related wiring, before any replacement of the 
"Core" Control Board and before replacing any of the related peripherals. 
A valid check of the wiring can be performed by removing the connectors from their location 
(both on the Control Board then on the related Peripheral) and by spraying inside the same 
connectors a small amount of Contact Cleaner liquid. Then, re-fit the connector in position and 
re-start the Auto-test routine, to see if the Error Warning is displayed again. 
 
 
Best regards. 
 
 
 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

GIAS S.r.l.  

 
 