background image

10

3-15

3-16

3-17

3-18

Headlight

What to buy

This cleaner uses a 12 volt, wedge base
type 912 bulb, Hoover 

part No.

27313101.

How to replace

Disconnect cleaner from electrical out-
let.

Belt replacement

The belt on your HOOVER cleaner 
causes the agitator to rotate and is
important for the effective operation of
the cleaner.  The belt is located under
the bottom plate of the cleaner and
should be checked from time to time 
to be sure it is in good condition.

When to replace

To check belt, remove bottom plate as
shown in “How to replace.”  Replace
belt if it is stretched, cut or broken.

What to buy

To assure effective operation, use only
genuine HOOVER belts with your 
cleaner.  When purchasing a new belt,
ask for Hoover 

part No. 40201190.

How to replace

Removing bottom plate

Disconnect cleaner from electrical 
outlet.

Place handle in low position and turn
cleaner over.

Remove the 4 screws as shown with a
Phillips screw driver.

Lift off bottom plate (A).

Removing used belt

Remove agitator brush roll and 
used belt. 

Discard used belt.

Removing hood

Place handle in low position.

Using a Phillips head screwdriver,
remove the 4 hood screws and lift off
carpet height control (A).

Lift hood off cleaner base just enough to
access the bulb.

Installing bulb and reposition-
ing hood

Pull old bulb straight out of socket.
Push new bulb straight into socket until
locked in place

Excessive force is not required.

Reposition hood, carpet adjustment
control and the 4 screws. Tighten
screws securely.

3-19

3-20

3-21

Positioning belt over pulley

With lettering on outside of belt and
positioned as shown in box on (C), slide
new belt over motor pulley (B).

Positioning belt over brush
roll

Insert brush roll through belt and place
belt in belt guide (D) on brush roll.

Installing brush roll

Grasp brush roll firmly and fit it into posi-
tion by first sliding end opposite the belt
into the rectangular slot (E) on side of
cleaner.

Pull other side of brush roll (F) into
place.

Turn brush roll making sure belt is not
pinched between brush roll and cleaner
base. 

A

A

B

C

D

E

F

Содержание Bagless Upright Vacuum Cleaner

Страница 1: ...HOOVER Bagless Upright with Twin Chamber System Read this manual before operating the cleaner ENGLISH pp 1 13 ESPA OL p g 14 21 FRAN AIS p 22 29 Owner s Manual www hoover com...

Страница 2: ...or when wearing open toe shoes or sandals Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use to pick up flammable or combustible materials such as ga...

Страница 3: ...a representative in our Consumer Response Center OR Visit us on line at www hoover com to find the service outlet nearest you click on the Service button Carton contents Remove all parts from carton a...

Страница 4: ...rt cup assembly helps in assembling your cleaner Assembly can be continued if the switch lock is missing However do not remove the switch lock until assembly is completed 1 8 1 9 1 7 B C D With dirt c...

Страница 5: ...itch 3 Carry handle 4 Cord hooks starting at the bottom hook wrap cord around hooks for storage The top hook can be rotat ed right or left for easy cord release 5 Dirt cup latch 6 Dirt cup lid 7 Dirt...

Страница 6: ...iance has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fi...

Страница 7: ...th the dusting brush and or extension wand D Extension wand is used to give extra length to your hose Attach it to any of the above tools C Attach wand and tools The tools are attached to the hose or...

Страница 8: ...sconnect cleaner from electrical outlet Do not use cleaner without dirt cup or filters in place Lift latch F on front of cleaner to release dirt cup Remove lid Note it is not necessary to remove the H...

Страница 9: ...dry thoroughly It is recommended that the HEPA car tridge filter be cleaned by tapping either of the ends DO NOT tap soft pleated sides of HEPA cartridge filter as this could damage the filter Tap fil...

Страница 10: ...ver Lift off bottom plate A Removing used belt Remove agitator brush roll and used belt Discard used belt Removing hood Place handle in low position Using a Phillips head screwdriver remove the 4 hood...

Страница 11: ...ings The agitator is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer Depot Service To obtain a...

Страница 12: ...e Clearing blockages section Incorrect setting Move carpet height control to Cleaning Tools Problem Cleaner hard to push Possible cause Possible solution Incorrect carpet height setting Move carpet he...

Страница 13: ...efore service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty Service Dealers Depots For an automated referral of authorized service outlets in the U S A phone 1 800 944 9200...

Отзывы: