1   System Overview 

The  X-618  Public  Address  System  provides  a  complete  multiple  sound  source  public  audio 
management solution. Centralized network management is achieved through the system software, 
and all system states are monitored. The X-618 Public Address System is hereby referred to as the 
“X-618” throughout the remainder of this manual. 

The X-618 includes the following product components: 

 

X-DCS3000 Digital Integrated System Manager  

The X-DCS3000 Digital Integrated System Manager is hereinafter referred to as the “DCS”. 
When describing specific installation requirement, the X-DCS3000 is referenced. 

The DCS is X-618 control equipment, is designed for expanding the number of loudspeaker 
zones, and can support multiple sound source files for broadcasting. The system integrates 
with functions such as the sound source file the storage system, the network audio 
broadcasting system, the loudspeaker zone control system, and the system for monitoring and 
diagnosing faults. 

 

X-DA1500/DA2250/DA4125 High Efficiency Power Amplifier 

The X-DA1500/DA2250/DA4125 High Efficiency Power Amplifier is hereinafter referred to as 
the “DA” or the “X-DA1500/DA2250/DA4125”. 

In the X-618 system, the DA is used to amplify audio signal power and drive many 
broadcasting loudspeakers. 

 

X-NPMS Configurable Network Paging Console 

The X-NPMS Programmable Network Paging Console is used to page zones and control 
broadcasts for the X-618 on an Ethernet network.  

 

 X-NRI Network Resource Interface 

The X-NRI Network Resource Interface is hereinafter referred to as the “NRI” or “X-NRI”.  

The X-NRI is the external interface expansion control equipment in the X-618. It has multiple 
audio interfaces and control ports enabling it to send audio and control signals through the 
Ethernet network to the X-618 system. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание X-618

Страница 1: ...M_2000061032_EN_3 2 X 618 Public Address System Installation Manual 2000061140 X 618 Installation Manual_FCC_V1 23 ...

Страница 2: ......

Страница 3: ...The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Honeywell shall have no liability for any error or damage of any kind resulting from the use of this document Trademark List All trademarks mentioned herein are the property of their respective owners These are shown in the document Trademark Information ...

Страница 4: ......

Страница 5: ...t Avoid blocking or impeding the ventilation holes on the unit To prevent unnecessary problems install the unit in a place free from any vibrations direct sunlight humidity or dust circulation Prevent liquids or other materials to enter cabinet If the unit gets wet or any foreign material enters the amplifier cabinet immediately disconnect the AC power cord and consult your dealer or qualified tec...

Страница 6: ...ng or splashing and no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture The mains plug is used as disconnecting device and shall remain readily operable The apparatus is unsuitable for use in air handling spaces This device complies with part 15 of the FCC Rules Operation...

Страница 7: ...e Cabinet 1310 Installing the DCS NRI and DA into the associated appliance cabinet 1310 Installing the X NPMS on a Cabinet 1411 Connecting the X 618 System Components 1512 Connecting the Sound Source Equipment to the DCS or NRI 1512 Connecting the DCS to the DA 1613 Connecting the Dry Contacts Optional 1916 Connecting the Noise Detector Optional 2218 Connecting the Loudspeakers 2421 Connecting the...

Страница 8: ...ainly for personnel who are to install operate and maintain the X 618 Broadcasting System Relevant Documents The following documents can be used as a reference when reading this manual X 618 Public Address System Product Description X 618 Public Address System Configuration Manual X 618 Public Address System Operation Manual Use Instructions All content including figures in this manual are to be u...

Страница 9: ...functions such as the sound source file the storage system the network audio broadcasting system the loudspeaker zone control system and the system for monitoring and diagnosing faults X DA1500 DA2250 DA4125 High Efficiency Power Amplifier The X DA1500 DA2250 DA4125 High Efficiency Power Amplifier is hereinafter referred to as the DA or the X DA1500 DA2250 DA4125 In the X 618 system the DA is used...

Страница 10: ...4 The X DCS3000 is capable of connecting to 8 main amplifier channels and 2 standby amplifier channels See connection diagrams in Figure 1 3 for 4 amplifier channel system ...

Страница 11: ...5 ...

Страница 12: ...6 Figure 1 Connection Schematic Diagram of X DCS3000 and X DA1500 ...

Страница 13: ...7 Figure 2 Connection Schematic Diagram of X DCS3000 and X DA2250 ...

Страница 14: ...8 Figure 3 Connection Schematic Diagram of X DCS3000 and X DA4125 ...

Страница 15: ...ols before installing the system equipment Electrostatic wrist band Electrostatic gloves Wire stripping pliers Wire cutting pliers RJ45 crimp tool Slotted screwdriver M2 Phillips screwdriver P1 Preparing Auxiliary Materials Prepare the following auxiliary materials before installing the system equipment Insulating tape Wire buckles Cable labels Plastic ties Preparing Cables and Auxiliary Equipment...

Страница 16: ...e of 16AWG is recommended for DCS Power amplifier audio input cable Audio input cables are provided in the package containing the DA but the lengths of these cables are limited If these cables cannot meet the requirements of the system wiring situation users need to obtain or create appropriate cables themselves Please prepare such audio input cables with the specifications as listed in Table 2 Th...

Страница 17: ...nd 4 wire volume controllers must be connected through dry contacts this equipment and the appropriate cables must be prepared beforehand Noise detector optional When environmental noise is present and the volume of broadcasts need to be automatically regulated you will need a noise detector and the appropriate cables For connecting the X DCS3000 with X ND100 the maximum cable distance between the...

Страница 18: ...erials such as plastic ties must be used for all connection cables When moving the cables prevent the power supply cables from coming in contact with the signal data cables Install appropriate electrical cable bushings at the cabinet opening before installing the cables in the appliance cabinets The spaces reserved for the cables at the cabinet opening must be blocked if these spaces are not used ...

Страница 19: ... and device Before installation inner space of the cabinet should be arranged based on the actual number and types of devices The bottom plate needs to be installed and the empty spaces can be filled with blind disk The X 618 spare list includes foot for the bottom of the device which is used for desktop installation Make sure there is no foot installed at the bottom of the device before installat...

Страница 20: ...evice in the cabinet Installing the X NPMS on a Cabinet The X NPMS Configurable Network Paging Console and the key module extensions X K4 or X K8 can be installed in the cabinet according to customer s requirements Before installation the X NPMS and extension key module should be installed together first The installation process is as follows 1 Use cables to connect the devices Pay attention to th...

Страница 21: ...sound source connected to the DCS will be used for broadcasting in this devices zones The sound source connected to the NRI will be used for broadcasting in all the zones of the X 618 system Connecting the X DCS3000 to the Sound Source Equipment For the X DCS3000 Digital Integrated System Manager there are 3 local auxiliary audio input interfaces in which interface 1 uses the RCA port and interfac...

Страница 22: ...e 2 rows of interfaces of audio output interface control interface on DCS Lower interfaces include 2 audio signals and upper interfaces include 1 audio signal The upper interfaces correspond to the even channel of lower interfaces For example if the lower channels are 1 and 2 the upper channel should be 2 Note The DCS can be connected to the power amplifier in the following configurations Connect ...

Страница 23: ...ifier wiring terminal and connect the cable to the power amplifier output wiring terminal 7P green phoenix tail seating 5 08mm and tighten the screws Refer to Figure 12 Figure 12 Connecting the Audio Output Cable to the Power Amplifier Input Wiring Terminal c Feed the other end of the audio output cable through the DCS protective cover of the terminal d Connect the end of the cable that was fed th...

Страница 24: ...iagram of the X DCS3000 1070V Audio Input Wiring Terminal Installation g Carefully check the input and output cables of the DCS that connect to the amplifier ensuring the channels are correct h Cover the power amplifier terminal with the protective terminal cover and tighten the screws as shown in Figure 15 This same operation applies to the DCS terminal and related protective cover Figure 15 Sche...

Страница 25: ... dry contact cable with diameter of 0 5 to 1 5mm to the dry contact input terminal Strip the wire jacket off one end of the prepared dry contact connection cable by about 10mm insert the wires into the dry contact wiring terminal and tighten the screws 2 Insert the dry contact input wiring terminal of the installed input cable into the DCS dry contact port and connect the external dry contact equi...

Страница 26: ...y contact wiring terminal 8P green phoenix tail seating 3 81mm and tighten the screws 2 Insert the dry contact output wiring terminal of the installed output cable into the DCS dry contact port 3 Connect the external equipment or switch to the other end of the dry contact output cable Figure 18 is schematic diagram of the DCS and three line volume controller connection Figure 19 is schematic diagr...

Страница 27: ...lly open and common contacts 0 Strip off the wire jacket of one end of prepared dry contact output cable by about 10mm insert dry contact wiring terminal 6P green phoenix tail seating 3 5mm and tighten the screws 0 Insert the dry contact output wiring terminal of the installed output cable into the NRI dry contact port 0 Connect the fire alarm system Figure 20 is schematic diagram of the NRI and f...

Страница 28: ...f third party system is voltage signal please use relay to switch the signal Connecting the Noise Detector Optional If environmental noise detection is required the AVC port should be used to connect the noise detector to the system Only the X ND100 is compatible with the X DCS3000 Shielded twisted pair cables are used to supply power as well as transfer the noise data signal The steps are as foll...

Страница 29: ...ose a fix method based on the surrounding situation It can be embedded in ceiling or install it though hanging 7 If the appearance of noise detector is similar to the end of line supervision module installation can be conducted according to corresponding method Figure 21 Schematic Diagram of the X DCS3000 Connection to the Noise Detector Connecting Module X EOL End of line supervision modules and ...

Страница 30: ... many modules at one line connect them one by one and combine with loudspeaker end of line respectively 1 Use screws to secure modules on wall Schematic Diagram of the X DCS3000 Connection to the X EOL Caution Each DLC bus on the X DCS3000 cannot exceed more than 5 devices Connecting the Loudspeakers The DCS can be directly connected to loudspeakers The following steps describe this process ...

Страница 31: ... Ethernet The DCS and NRI can be connected to the NPM in the following two ways Directly connecting the DCS and NRI to the NPM Connecting the DCS and NRI to the NPM through a network switch Directly Connecting the DCS and NRI to the NPM Use twisted pair cables to connect the network ports of the DCS the NRI and the NPM Insert one end of the prepared twisted pair cable into the network port located...

Страница 32: ...d the NRI to the NPM through a Network Switch Connecting the Power Supply Cables The power supply cables for the main X 618 system components include the following items DCS or NRI Main and Standby Power Supply Cables DA Main and Standby Power Supply Cables ...

Страница 33: ...olarity of the device The wires are identified as L Live wire N Neutral wire and E Earth wire 2 Tighten the screws to prevent the power supply cable from coming loose and cover the power supply interface set 3 Insert the wiring terminal of the installed power supply cable into the AC power supply input port of the X NRI or amplifier and tighten the screws at both ends 4 Insert the other end of the...

Страница 34: ...as shown below 2 Tighten the screws and cover the power supply interface set 3 Insert the wiring terminal of the installed power supply cable into the main power supply input port of the DA and tighten the screws at both ends 4 Insert the other end of the main power supply cable into the main power supply equipment Connecting the Standby Power Supply Cable 1 Strip off the wire jacket of one end of...

Страница 35: ...rent DC input interface places The output current is 1A Connecting the Power over Ethernet The X NPMS can be powered by the power over Ethernet Use a twisted pair cable to connect the X NPMS with POE switch There is no need to connect to power supply cables or power adapter Caution When X NPMS is connected to many key extension modules and powered by POE we recommend to use POE switcher which supp...

Страница 36: ...30 ...

Страница 37: ... can announce the IP address in the monitoring speakers to confirm the IP address of DCS Press the buttons in order not release Fn and CLOSE one by one then follow the reverse order to release button Please release CLOSE button first then release Fn The device will indicate successful programming with a beep The speaker inside the DCS will play the ID voice and announce the IP address You cannot p...

Страница 38: ...thford CT 06472 USA Tel 1 800 289 3473 www honeywellav com Life Safety A V Guangzhou Co Ltd Address No 257 Junye Road Guangzhou GETDD East 510530 China Tel 86 0 20 2839 9600 Fax 86 0 20 2820 8706 2018 Life Safety A V Guangzhou Co Ltd All rights reserved ...

Отзывы: