Honeywell W884B Скачать руководство пользователя страница 10

10

Home and Building Control

Home and Building Control

Helping You Control Your World

Honeywell Inc.

Honeywell Limited—Honeywell Limitée

1985 Douglas Drive North

740 Ellesmere Road

Golden Valley, MN 55422

Scarborough, Ontario
M1P 2V9

Printed in U.S.A.

QUALITY IS
KEY

Содержание W884B

Страница 1: ... The W884E includes a dehumidifier control All comfort controls are combined in the W884 to make a convenient attractive control center CONTENTS Specifications 2 Ordering Information 2 Recycling Notice 3 Installation 4 Settings and Adjustments 7 Checkout 9 Humidistat dial on the W884B can be set for prevailing outdoor temperature to provide opti mum relative humidity over a wide range of con ditio...

Страница 2: ... outdoor temperature W884E The dial is marked ON LOW NOR MAL HIGH and OFF Optimum relative hu midity is maintained by rotating the humidity selection dial DIFFERENTIAL 4 to 6 percent RH cycling at midscale THERMOSTAT RATINGS Switching Spdt Switch Rating 1 5A at 30 Vac Range 50 F to 100 F 10 C to 38 C Adjustable Heat Anticipator Range 0 10 to 1 2A factory set at 0 4A SUBBASE RATINGS System Switch C...

Страница 3: ... at the end of its useful life If this control is replacing a control that contains mer cury in a sealed tube do not place your old control in the trash Contact your local waste management authority for instructions regarding recycling and the proper disposal of this control or of an old control containing mercury in a sealed tube If you have questions call Honeywell at 1 800 468 1502 M3375 ...

Страница 4: ...ant heat from the sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outside wall behind the thermostat MOUNTING IMPORTANT The thermostat used with the W884 was mounted at true level when calibrated at the fac tory The W884 must be level to maintain calibra tion 1 Remove cover and thermostat and level W884 at the selected location Mark locations for mounting screws a...

Страница 5: ...ion Push excess wire back into wall and plug the hole to prevent drafts from affect ing the W884 7 Mount the thermostat and replace W884 cover WIRING Disconnect power supply to prevent electrical shock or equipment damage All wiring must comply with local codes and ordi nances Wiring to the W884 must be NEC Class 2 Humidistat requires separate 24V power supply Refer to the wiring diagrams and inst...

Страница 6: ...AY W B G Y O H H Q539 DEHUMIDISTAT W884E 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED USED IN DUCT HEATER OR SIMILAR APPLICATIONS TO ENERGIZE SYSTEM FAN DURING HEATING M1335 FAN RELAY 2 2 SPST N C SWITCHING RELAY R 1 HUMIDIFIER RELAY COOLING DAMPER MOTOR COOLING CONTACTOR FAN RELAY HEATING RELAY W B G Y O H H Q539A HUMIDISTAT W884B 1 POWER SUPPLY PROVIDE DISCONNECT M...

Страница 7: ...et as recom mended and frost or condensation forms on inside windows adjust humidistat setting for outdoor tem per ature setting less 5 F 3 C Frost or condensa tion should disappear within 24 hours If not con tinue reducing outdoor temperature setting and ad just humidistat accordingly Humidity Selection W884B The humidity controller should be set at the prevail ing outdoor temperature This will p...

Страница 8: ... rating of the primary control this rating is usually stamped on the control nameplate Move the indicator on the scale to correspond with this rating and the heat anticipator will be properly adjusted Move the indicator with your fin gers a pin a pencil point or a wire inserted in the small hole See Fig 11 If the current rating is not given proceed as follows before mounting the thermostat 1 Conne...

Страница 9: ... system through one complete cycle to make sure all components function as intended CAUTION On low voltage gas system if jumpering gas valve to check system operation do NOT jumper across valve coil This may burn out thermostat heat anticipator See Fig 12 Fig 12 Do not jumper across valve coil ...

Страница 10: ...ome and Building Control Helping You Control Your World Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley MN 55422 Scarborough Ontario M1P 2V9 Printed in U S A QUALITY IS KEY ...

Отзывы: