W8635A EQUIPMENT INTERFACE MODULE

3

69-1339—2

Fig. 5. Three zone configuration.

Fig. 6. Using wire nut to pigtail a connection when 

three or more wires are terminated at one terminal.

Discovery Mode

Discovery mode begins when the T8635L Thermostat 
and W8635 EIM are first installed and power is 
connected:
— The W8635 EIM transmits information to the T8635L 

Thermostat that indicates the maximum number of 
stages that are enabled and the type of EIM 
connected.

— The thermostat receives information from the W8635 

and then sets the cycle rates and equipment types 
automatically.

Stage Configuration

The W8635A automatically configures the T8635L for 
two stages of heat and two stages of cool. If using the 
W8635A and the T8635L on a one heat/one cool 
application, set Installer Setup No. 5 and 8 to 1 when 
configuring the T8635L Communicating Thermostat.

For configuration combinations, see Table 3.

Table 3. Stage Combinations. 

Cycle Rate 

The thermostat automatically sets the cycle rate based 
on the information it received during Discovery Mode. 
See Table 4.

To change the default cycle rate settings:
— enter T8635L Thermostat Installer Setup and select 

the desired cycle rate settings for each stage. (All 
stages can be set between 1 and 12 cph.)

Table 4. Default Cycle Rate Settings.

Electric Heat Setting

When using the W8635A on an electric heat application, 
set the T8635L Thermostat Installer Setup No. 4 to 1. 
This instructs the W8635A EIM to energize the fan with 
any call for heat.

L1 
(HOT)

L2

1

SYSTEM

TRANSFORMER

COOL 1
RELAY

HEAT 2
RELAY

FAN 
RELAY

OT

OT

2

1

3

FACTORY INSTALLER JUMPERS.

M13430A

C7089B 
OUTDOOR
TEMPERATURE 
SENSOR

1

T8635L

HEAT 1
RELAY

W8635A

C

R

RH
RC

1

2

3

Y2

W2

Y1

G

W1

COOL 2
RELAY

W8703A

L1 
(HOT)

L2

EXTERNAL
40 VA
TRANSFORMER

OT

OT

2

1

3

T8635L

OT

OT

2

1

3

T8635L

ZONE A

ZONE B

ZONE C

CLOSE

OPEN

OPEN

CLOSE

OPEN

CLOSE

COM

TR1

TR2

2

3

1

5

4

6

Z

2

1

3

X

5

4

6

Z

2

1

3

X

5

4

6

Z

2

1

3

X

TROL-A-TEMP
MODEL AOBD

ZONE DAMPER

OPTIONAL 

TROL-A-TEMP

MODEL ARD-PC

 OR MODEL ZD

WIRE NUT

M13378

Heat Stages

Cool Stages

1

0

2

0

0

1

0

2

1

1

2

2

W8635A 

Equipment 

Interface 

Module

1

st

 

Stage 

Heat

2

nd

 

Stage 

Heat

1

st

 

Stage 

Cool

2

nd

 

Stage 

Cool

6 cph

6 cph

3 cph

3 cph

Содержание W8635A

Страница 1: ...ller must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation CAUTION Voltage Hazard Can cause electrical shock or equipment damage Disconnect power before supply before beginning installation Location CAUTION Mounting Location Hazard Mounting W8635A inside HVAC equipment can damage the EIM Mount the W8635A only on t...

Страница 2: ... CAUTION Voltage Hazard Can cause electrical shock or equipment damage Disconnect power before beginning installation 1 Loosen the terminal screws on the W8635A and connect the system wires See Fig 3 2 Securely tighten each terminal screw Fig 3 Wiring the W8635A terminals Table 2 Terminal Designations Fig 4 2H 2C single transformer Y2 W2 Y1 G W1 C R RH RC 1 2 3 MOUNTING HOLES 2 MOUNTING SCREWS 2 W...

Страница 3: ...sed on the information it received during Discovery Mode See Table 4 To change the default cycle rate settings enter T8635L Thermostat Installer Setup and select the desired cycle rate settings for each stage All stages can be set between 1 and 12 cph Table 4 Default Cycle Rate Settings Electric Heat Setting When using the W8635A on an electric heat application set the T8635L Thermostat Installer ...

Страница 4: ...ection period To start the Installer System Test 1 Press and hold the T8635L Thermostat increase and decrease keys at the same time until 10 appears All display segments display before the 10 appears See Fig 7 and 8 Fig 7 LCD segments display Fig 8 Installer Test Number display 2 Refer to Table 6 for Installer System Test option Test Number System Test Description 10 12 Heating stages can be turne...

Страница 5: ... returns to normal operating mode Table 6 Installer System Test Options Continued Key to Press Test Number Description Run Program Table 7 Troubleshooting Guide Symptom Possible Cause Action Display does not come on at thermostat Thermostat is not being powered Check if the thermostat is mounted and latched on the wallplate if not mount and latch the thermostat on the wallplate Check if the circui...

Страница 6: ...ing If the Flash COM OK LED blinks check that 24 Vac is present at Y1 terminal If 24 Vac is not present check R to Rh to Rc jumper connection If the R to Rh to Rc connection is good replace the W8635A EIM wait is displayed and the call for Cool has not started Compressor protection is in effect Compressor protection can be set from 0 to 5 minutes to prevent compressor damage due to rapid cycling W...

Отзывы: