W7752D,E,F,G FAN COIL UNIT CONTROLLERS 

 INSTALLATION INSTRUCTIONS 

 

 

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative:

 

 

Automation and Control Solutions 

Honeywell GmbH 
Böblinger Strasse 17 
71101 Schönaich / Germany 
Phone:  (49) 7031 63701 
Fax: 

(49) 7031 637493 

http://ecc.emea.honeywell.com 
Subject to change without notice. Printed in Germany 
 
EN0B-0250GE51 R0111B 

DGND
DIGITAL INPUT
LED
SETPOINT
FAN / BYPASS
TEMP SENSOR
AGND

LonWorks BUS IN

LonWorks BUS IN

LonWorks BUS OUT

LonWorks BUS OUT

OUT 1 COM
OUT 1 OPEN
OUT 1 CLOSE
OUT 2 COM
OUT 2 OPEN
OUT 2 CLOSE

RELAY COM
RELAY 1
RELAY 2
RELAY 3
SUPPLY VOLT
SUPPLY VOLT
PWR RELAY IN (D,F MODELS, ONLY)
PWR RELAY OUT (D,F MODELS, ONLY)

W7752 FAN COIL UNIT CONTROLLER

WALL MODULE

CONNECTIONS

L

ON

W

ORKS

NETWORK IN

L

ON

W

ORKS

 NETWORK OUT

OCCUPANCY SENSOR

CHANGEOVER CONTACT

AIRFLOW CONTACT

WINDOW CONTACT

MOTION SENSOR

OPEN

OPEN

CLOSE

CLOSE

COM

COM

HI

MED

LO

HEAT

COOL

REHEAT

RETURN

POWER MAINS

L

N

FAN

1

2
3
4
5
6
7
8
9

10

11

12
13
14
15
16
17
18

19
20

21

22
23
24
25
26

4A

0.5A

16A

 

Fig. 6. Input/output details 

 
 

Table 1. Output assignments for various actuator types 

output type 

Out 1 terminal 

Out 2 terminal 

 

13 

14 

15 

16 

17 

18 

floating 

24 Vac 

open 

close 

24 Vac 

open 

close 

1-stage 

24 Vac 

ON/OFF 

— 

24 Vac 

ON/OFF 

— 

2-stage 

24 Vac 

stage 1 

stage 2 

24 Vac 

stage 1 

stage 2 

3-stage 

24 Vac 

stage 1 

stage 2 

24 Vac 

stage 1 

stage 2 

 

 

stage 3 

 

stage 3 

PWM 

24 Vac 

PWM 

— 

24 Vac 

PWM 

— 

thermal 

24 Vac 

ON/OFF 

— 

24 Vac 

ON/OFF 

— 

 
 

Содержание W7752D2007

Страница 1: ...tions that allow clearance for wiring The controllers can be mounted on a panel with screws or by snapping onto standard EN 50 022 DIN rail 1 3 8 by 9 32 in 35 mm by 7 5 mm See Fig 1 for mounting dimensions See Fig 2 for DIN rail mounting The type and length of screw required for screw mounting depends upon the panel material used to mount the con troller The controller can be mounted either verti...

Страница 2: ...k configurations daisy chain loop and star configurations or any combination thereof are possible see also Excel 50 500 LONWORKS Mechanisms Interface Description EN0B 0270GE51 IMPORTANT Do not bundle wires carrying field device signals or LONWORKS communications together with high voltage power supply or relay cables Specifically maintain a min separation of 3 inches 76 mm between such cables Loca...

Страница 3: ... assignments for various actuator types Refer to job drawings for specific wiring diagrams IMPORTANT Screw type terminal blocks are designed to accept no more than one 14 AWG 2 5 mm2 conductor Multiple wires that are 14 AWG 2 5 mm 2 can be connected using a wire nut Include a pigtail with this wire group and attach the pigtail to the individual terminal block Fig 4 Terminal cover removal Wire to t...

Страница 4: ...OSE RELAY COM RELAY 1 RELAY 2 RELAY 3 SUPPLY VOLT SUPPLY VOLT PWR RELAY IN D F MODELS ONLY PWR RELAY OUT D F MODELS ONLY W7752 FAN COIL UNIT CONTROLLER WALL MODULE CONNECTIONS LONWORKS NETWORK IN LONWORKS NETWORK OUT OCCUPANCY SENSOR CHANGEOVER CONTACT AIRFLOW CONTACT WINDOW CONTACT MOTION SENSOR OPEN OPEN CLOSE CLOSE COM COM HI MED LO HEAT COOL REHEAT RETURN POWER MAINS L N FAN 1 2 3 4 5 6 7 8 9 ...

Отзывы: