Tables 4-10 and 4-11 show error messages that may appear in the DU screen when in operation or
during testing. In Table 4-11, the first column shows the Action Code, and the second column the
steps to take to erase the code and restore the unit to operation. If none of the steps work, the unit
must be returned to Chadwick-Helmuth for repair. Some of the error messages listed in this
section cannot be corrected in the field. If you see these messages displayed, return the unit to
Chadwick-Helmuth.
The serial printer fails to print
from the AU.
The serial cable is not
connected.
Connect the serial cable.
The DIP Switch settings
are incorrect.
Refer to Section 2.2.3.2 for
information on setting the
printer DIP Switches.
The printer is turned off.
Turn on the printer power.
The printer power is not
connected and/or the
battery is too low.
Insert the printer power plug
from cable 902-15371 into
the printer power jack on the
back of the printer.
The wrong printer is
selected in the DP.
Pull down the
File
menu in
the DP main window.
Select Print (AU Printer)
Select the desired logs from
the Print Menu.
The “ACQUISITION ERROR
NO MAG PICKUP” message is
displayed.
Magnetic pickup cable is
not connected.
Make sure magnetic pickup
cable is connected to the
sensor and to the correct input
on the AU.
The magnetic pickup is not
gapped properly.
Make sure that the gap
between the magnetic pickup
and the interrupter is 0.05 in.
±0.01in.
Table 4-9. Common VXP System Problems (Continued)
Symptom
Probable Cause
Corrective Action
Содержание VXP
Страница 4: ...iv Honeywell ...
Страница 8: ...viii Honeywell ...
Страница 10: ...x Honeywell ...
Страница 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Страница 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Страница 28: ...1 18 Honeywell Introduction ...
Страница 36: ...2 8 Honeywell Preparation for Use ...
Страница 68: ...4 24 Honeywell Maintenance ...
Страница 76: ...5 8 Honeywell Repair and Cleaning Figure 5 6 Wiring Schematic for Computer Connector Cable PN 15371 ...
Страница 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Страница 88: ...7 4 Chadwick Helmuth Company Inc Cable Parts List Figure 7 2 Magnetic Pickup Cable P N 902 10808 ...
Страница 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Страница 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Страница 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Страница 96: ...7 12 Chadwick Helmuth Company Inc Cable Parts List Figure 7 6 Computer Connector Cable P N 902 15371 ...
Страница 98: ...7 14 Chadwick Helmuth Company Inc Cable Parts List Figure 7 7 ICP Accelerometer Cable P N 902 15384 ...
Страница 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Страница 102: ...8 2 Honeywell Wiring Diagram ...
Страница 103: ......
Страница 104: ......
Страница 105: ......