Pre-Lighting Checks

1.

Before lighting, smell around the appliance area 
for gas. If the appliance uses LP gas, be sure to 
smell next to the floor because LP gas is heavier 
than air.

2.

If you smell gas, immediately shut off the manual 
valve in the gas piping to the appliance or, on LP, 
at the tank. Leave the building immediately and 
call your gas supplier. If your gas supplier cannot 
be reached, call the fire department.

3.

Do not force the gas valve control knob. Use only 
your hand to turn the control knob.

4.

If the knob does not operate by hand, the valve 
should be replaced by a qualified service techni-
cian.

5.

The gas valve must be replaced if it was flooded 
with water. Call a qualified service technician.

6.

The gas valve is a safety device. It must be 
replaced in the event of any physical damage 
such as bent terminals, missing or broken parts, 
stripped threads, or evidence of exposure to heat.

IMPORTANT

Follow the operating instructions provided by 
the manufacturer of your heating appliance.

Содержание VS8420C

Страница 1: ...ith EN 88 class C Natural Gas 9 mbar typical LP 27 mbar typical Regulator Adjustments Standard Regulator Natural Gas 7 5 mbar to 12 5 mbar field adjustable LP 20 mbar to 30 mbar field adjustable In appliances where no regulation is required the pres sure regulator must be blocked by turning the pressure regulator adjustment screw fully down The regulator will then be set at 30 mbar Voltage VS8420 ...

Страница 2: ...onvert from natural gas to LP High low regulator model VS8420C cannot be converted Location Locate the combination gas valve where it cannot be affected by steam cleaning high humidity dripping water corrosive chemicals dust or grease accumula tion or excessive heat To assure proper operation follow these guidelines Locate gas valve in a well ventilated area Mount gas valve high enough to avoid ex...

Страница 3: ...pilot burner according to the manufacturer s instructions WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not bend tubing at gas valve after compres sion fitting has been tightened as this may result in a gas leak at the connection Fig 3 Top view of gas valve with HI LO regulator Fig 4 Top view of gas valve with standard regulator GAS CONTROL GAS CONTROL HORIZO...

Страница 4: ...ting stamped on the valve operator Table 1 Maximum Thermostat Wire Length ECO Connection Supplementary 1 Push the ECO into the window of the gas valve See Fig 5 2 The leadwires of the ECO must be equipped with insulated 6 3 mm female quick connect terminals 3 Leadwire length must not exceed the length as shown in Table 2 Table 2 Maximum Length mm of Supplementary Limit Leadwires When Using Q309A T...

Страница 5: ...erclockwise to the ON position On a call for heat the main valve opens and the main burner ignites Shut off Procedure 1 To shut off the system turn the knob clockwise to the OFF position This action closes the main gas and safety valves however the power unit must drop out before the lighting sequence can begin again The VS8420 drops out within 30 seconds 2 To relight the pilot light follow the st...

Страница 6: ...ot gas flow Gas valve and thermostat control main burner gas flow PILOT Opens pilot valve and allows gas flow to the pilot burner HI LO Manually adjusts outlet pressure NOTE Valves are shipped with the gas control knob in the ON position Perform Gas Leak Test WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Stand away from the main burner while lighting Hidden gas ...

Страница 7: ...equipment operates 100 000 to 200 000 cycles per year This heavy cycling can wear out the gas valve in one to two years Exposure to water dirt chemicals and heat can damage the gas valve and shut down the control system The maintenance program should include regular system checkout as outlined in the Checkout section and checkout of the control system as described in the appliance manufacturer lit...

Страница 8: ...ff the manual valve in the gas piping to the appliance or on LP at the tank Leave the building immediately and call your gas supplier If your gas supplier cannot be reached call the fire department 3 Do not force the gas valve control knob Use only your hand to turn the control knob 4 If the knob does not operate by hand the valve should be replaced by a qualified service techni cian 5 The gas val...

Отзывы: