Honeywell VS8420C Скачать руководство пользователя страница 5

VS8420C,M MILLIVOLT GAS VALVE

5

69-1304

Fig. 6. Installing ECO in window.

Fig. 7.  Millivolt system wiring diagram with quick 

drop-out thermocouple (VS8420D).

Pilot Gas Lighting Procedure

Lighting Standard Pilot (Without Piezo)

1.

Turn the knob counterclockwise 

to the 

PILOT position, push the knob down, and hold in 

position. The pilot valve opens and allows gas to 
flow to the pilot burner.

2.

Light the pilot burner while holding down the knob 
until a strong flame is present (approximately 60 
seconds).

3.

Release the knob. The shaft will move upward 
and engage the safety valve lever that opens the 
safety valve.

4.

Turn the knob counterclockwise  

 to the ON 

position. On a call-for-heat, the main valve opens 
and the main burner ignites.

Lighting Pilot with Piezo

1.

Turn the knob counterclockwise  

 to the 

PILOT position, push the knob down, and hold in 
position. The pilot valve opens and allows gas to 
flow to the pilot burner.

2.

Push the plunger on the piezo until the pilot 
burner is lit. Hold down the knob until a strong 
flame is present (approximately 60 seconds).

3.

Release the knob. The shaft will move upward 
and engage the safety valve lever that opens the 
safety valve.

4.

Turn the knob counterclockwise  

 to the ON 

position. On a call-for-heat, the main valve opens 
and the main burner ignites.

Shut off Procedure

1.

To shut off the system, turn the knob clockwise to 
the OFF position. This action closes the main gas 
and safety valves; however, the power unit must 
drop out before the lighting sequence can begin 
again. The VS8420 drops out within 30 seconds.

2.

To relight the pilot light, follow the steps in the 
Pilot Gas and Lighting Procedure section.

HI/LO Regulator

As you turn the HI/LO knob, the gas pressure changes.

1.

Turn the knob clockwise  

toward the HI set-

ting to increase gas pressure.

2.

Turn the knob counterclockwise  

  toward 

the LO setting to decrease gas pressure.

Minimum and maximum regulator settings vary for each 
individual gas valve. Table 3 lists possible minimums 
and maximums for gas valves. See gas valve label for 
actual minimum and maximum ranges.

Table 3.  HI/LO and Standard Regulator Pressures in mbar (in. wc).

ECO
CONNECTOR

M13322

M12678

HI/LO
REGULATOR

OFF

PILOT

O

N

PIEZO SPARKER

PILOT 
ADJUSTMENT 
SCREW

GAS 
CONTROL 
KNOB

Q313
THERMOPILE

HIGH LIMIT 
CONTROL

MILLIVOLT
THERMOSTAT

ELECTRODE

TARGET

QUICK DROP-OUT
THERMOCOUPLE

VS8420 HI/LO MILLIVOLT GAS VALVE

Type of Gas

Hi/Lo Regulator Setting Ranges

Standard Regulator Setting 

Ranges

Hi

Lo

Natural

7.5 to 9 (3.0 to 3.5)

3 to 6 (1.2 to 2.5)

(3.0 to 5.0)

LP

22.5 to 27.5 (9.0 to 11.0)

9 to 16 (3.7 to 6.5)

(8.0 to 12.0)

Содержание VS8420C

Страница 1: ...ith EN 88 class C Natural Gas 9 mbar typical LP 27 mbar typical Regulator Adjustments Standard Regulator Natural Gas 7 5 mbar to 12 5 mbar field adjustable LP 20 mbar to 30 mbar field adjustable In appliances where no regulation is required the pres sure regulator must be blocked by turning the pressure regulator adjustment screw fully down The regulator will then be set at 30 mbar Voltage VS8420 ...

Страница 2: ...onvert from natural gas to LP High low regulator model VS8420C cannot be converted Location Locate the combination gas valve where it cannot be affected by steam cleaning high humidity dripping water corrosive chemicals dust or grease accumula tion or excessive heat To assure proper operation follow these guidelines Locate gas valve in a well ventilated area Mount gas valve high enough to avoid ex...

Страница 3: ...pilot burner according to the manufacturer s instructions WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not bend tubing at gas valve after compres sion fitting has been tightened as this may result in a gas leak at the connection Fig 3 Top view of gas valve with HI LO regulator Fig 4 Top view of gas valve with standard regulator GAS CONTROL GAS CONTROL HORIZO...

Страница 4: ...ting stamped on the valve operator Table 1 Maximum Thermostat Wire Length ECO Connection Supplementary 1 Push the ECO into the window of the gas valve See Fig 5 2 The leadwires of the ECO must be equipped with insulated 6 3 mm female quick connect terminals 3 Leadwire length must not exceed the length as shown in Table 2 Table 2 Maximum Length mm of Supplementary Limit Leadwires When Using Q309A T...

Страница 5: ...erclockwise to the ON position On a call for heat the main valve opens and the main burner ignites Shut off Procedure 1 To shut off the system turn the knob clockwise to the OFF position This action closes the main gas and safety valves however the power unit must drop out before the lighting sequence can begin again The VS8420 drops out within 30 seconds 2 To relight the pilot light follow the st...

Страница 6: ...ot gas flow Gas valve and thermostat control main burner gas flow PILOT Opens pilot valve and allows gas flow to the pilot burner HI LO Manually adjusts outlet pressure NOTE Valves are shipped with the gas control knob in the ON position Perform Gas Leak Test WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Stand away from the main burner while lighting Hidden gas ...

Страница 7: ...equipment operates 100 000 to 200 000 cycles per year This heavy cycling can wear out the gas valve in one to two years Exposure to water dirt chemicals and heat can damage the gas valve and shut down the control system The maintenance program should include regular system checkout as outlined in the Checkout section and checkout of the control system as described in the appliance manufacturer lit...

Страница 8: ...ff the manual valve in the gas piping to the appliance or on LP at the tank Leave the building immediately and call your gas supplier If your gas supplier cannot be reached call the fire department 3 Do not force the gas valve control knob Use only your hand to turn the control knob 4 If the knob does not operate by hand the valve should be replaced by a qualified service techni cian 5 The gas val...