Honeywell VR8215 Series Скачать руководство пользователя страница 8

VR8215S,T DIRECT IGNITION COMBINATION GAS CONTROLS

Automation and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN  55422

Toronto, Ontario  M1V 4Z9

customer.honeywell.com

® U.S. Registered Trademark
© 2008 Honeywell International Inc.
69-2253—01    M.S.  08-08 

To Turn ON Appliance

STOP! Read the Warnings 

Above Before Proceeding.

1.

The lighting sequence on this appliance is 
automatic; 

do not attempt to manually light the 

main burner.

2.

If the furnace does not come on when the 
thermostat is set several degrees above room 
temperature, set the thermostat to its lowest setting 
to reset the safety control.

3.

Remove the burner access panel if provided on 
your appliance.

4.

Push the on-off switch to the OFF 
position.

5.

Wait five minutes to allow any gas in the 
combustion chamber to vent. Then if you smell 
gas, STOP! Follow Step 1 in the Warning above. If 
you do not smell gas, continue with the next step.

6.

If you do not smell gas, push the electronic on-off 
switch to the ON position.

7.

Replace the burner access panel.

8.

Reset the thermostat to the desired temperature.

9.

If the appliance does not turn on, turn the gas 
control switch to OFF and contact a qualified 
service technician for assistance.

Turning Off the Appliance

Vacation Shutdown

Set the thermostat to the desired room temperature while 
you are away.

Complete Shutdown

1.

Turn off power to the appliance. 

2.

Turn off the gas supply to the appliance. 

3.

Push the on-off switch to the OFF 
position. Appliance will completely shut off. 

4.

Follow the procedure in the Instructions to the 
Homeowner section above to resume normal 
operation.

Содержание VR8215 Series

Страница 1: ... Body Pattern Straight through see Table 1 for inlet and outlet size Electrical Ratings Voltage and Frequency 24 Vac 60 Hz Current Draw 0 5A Capacity See Table 1 Conversion Use conversion factors in Table 2 to convert capacities for other gases Regulation Range See Table 1 Natural LP Gas Conversion Kits See Table 4 Approvals CSA Design Certificate Table 4 Natural LP Gas Conversion Kits Model Size ...

Страница 2: ...system Corrosive Chemicals Corrosive chemicals can attack the control eventually causing a failure If chemicals are used for routine cleaning avoid contact with the control Where chemicals are suspended in air as in some industrial or agricultural applications protect the control with an enclosure Dust or Grease Accumulation Heavy accumulations of dust or grease can cause the control to malfunctio...

Страница 3: ...lacement application mount the gas control in the same location as the old control Locate the combination gas control where it cannot be affected by steam cleaning high humidity or dripping water corrosive chemicals dust or grease accumulation or excessive heat To assure proper operation follow these guidelines Locate gas control in a well ventilated area Mount gas control high enough above cabine...

Страница 4: ...gas control and make sure it matches the available supply Install a transformer and other controls as required 2 Connect the control circuit to the gas control terminals See Fig 7 and 8 3 Adjust thermostat heat anticipator to 0 50A rating stamped on valve label GAS CONTROL GAS CONTROL HORIZONTAL DROP PIPED GAS SUPPLY PIPED GAS SUPPLY 3 IN 76 MM MINIMUM 3 IN 76 MM MINIMUM RISER GAS CONTROL TUBING G...

Страница 5: ...k in the appliance vestibule 4 With the main burner in operation paint the pipe joints including bushings and the control inlet and outlet with rich soap and water solution 5 If another leak is detected turn the gas control to off tighten the joints and pipe connections 6 Replace the part if a leak cannot be stopped Turn On System Push the on off switch to the ON position Turn On Main Burner Follo...

Страница 6: ...ounterclockwise to decrease the gas pressure to the burner c Always replace the cap screw and tighten firmly to prevent gas leakage 5 If the desired outlet pressure or flow rate cannot be achieved by adjusting the gas control check the gas control inlet pressure using a manometer at the inlet pressure tap of the gas control If the inlet pressure is in the nominal range see Tables 6 and 7 replace t...

Страница 7: ... as if it has been wet SERVICE WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not disassemble the gas control it contains no replaceable components Attempted disassembly repair or cleaning can damage the control resulting in gas leakage CAUTION Equipment Damage Hazard Can burn out thermostats or other components in the control string Never apply a jumper acros...

Страница 8: ...n your appliance 4 Push the on off switch to the OFF position 5 Wait five minutes to allow any gas in the combustion chamber to vent Then if you smell gas STOP Follow Step 1 in the Warning above If you do not smell gas continue with the next step 6 If you do not smell gas push the electronic on off switch to the ON position 7 Replace the burner access panel 8 Reset the thermostat to the desired te...

Отзывы: