Honeywell VR4300 Скачать руководство пользователя страница 5

TABLE 5—MAXIMUM LENGTH OF SUPPLEMENTARY LIMIT LEADWIRES WHEN USING Q340A

THERMOCOUPLE.

Thermocouple

Maximum Leadwire Length x 2 (Wires)

Length

AWG No. 14

AWG No. 16

AWG No. 18

Inches

Meters

Inches

Meters

Inches

Meters

Inches

Meters

18

0.5

35

0.9

22

0.6

13

0.3

24

0.6

29

0.7

18

0.5

11

0.3

30

0.8

23

0.6

15

0.4

9

0.2

36

0.9

17

0.4

11

0.3

6

0.2

48

1.2

Do not use.

60

1.5

TABLE 6—MAXIMUM LENGTH OF SUPPLEMENTARY LIMIT LEADWIRES WHEN USING Q309A

THERMOCOUPLE.

Thermocouple

Maximum Leadwire Length x 2 (Wires)

Length

AWG No. 14

AWG No. 16

AWG No. 18

Inches

Meters

Inches

Meters

Inches

Meters

Inches

Meters

12

0.3

47

1.2

30

0.8

18

0.5

18

0.5

41

1.0

26

0.7

16

0.4

24

0.6

35

0.9

22

0.6

14

0.4

30

0.8

29

0.8

18

0.5

11

0.3

36

0.9

23

0.6

15

0.4

9

0.2

40

1.0

19

0.5

12

0.3

7

0.2

48

1.2

11

0.3

7

0.2

60

1.5

Do not use.

Fig. 7—Installing thermocouple to the power unit.

Fig. 8—Wiring connections for 120 volt control.

5

69-0683—1

120V 
THERMOSTAT

POWER SUPPLY.  PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.

DO NOT JUMPER THESE TERMINALS.  THIS 
SHORTS VALVE COIL AND MAY BURN OUT 
ANTICIPATOR IN THERMOSTAT.

OPTIONAL HIGH LIMIT.

L1
(HOT)

L2

1

HIGH LIMIT 
CONTROLLER

M3092A

GAS CONTROL TERMINALS

L2

L1

2

3

1

2

3

1

THERMOCOUPLE 
LEAD

1

THIS IS AN ELECTRICAL CONECTION AND MUST BE CLEAN 
AND DRY.  DO NOT USE PIPE COMPOUND.

M3096

Содержание VR4300

Страница 1: ...ontinuous pilot gas controls are used in gas fired applianceswithcapacitiesupto300feet3 houratoneinchwc pressure drop 5 7 meters3 hour at 0 25 kPa on natural gas They include a manual valve safety shutoff two automatic operators a pressure regulator pilot adjustment and a con duit cover See Table 1 for temperature ranges and regulator types BODY PATTERN Straight through body pattern INLET X OUTLET...

Страница 2: ...gascontrolsetfornaturalgasonLPgas or a gas control set for LP gas on natural gas To convert a gas control from natural gas to LP gas or from LP gas to natural gas contact your Honeywell representative Convert standard or slow opening gas controls from one gas to another with a conversion kit ordered sepa rately Order part number 393691 to convert from natural to LP gas Order part number 394588 to ...

Страница 3: ...as Control 1 Mount the gas control 0 90 degrees in any direction including vertically from the upright position of the gas control knob 2 Mount the gas control so gas flow is in the direction of the arrow on the bottom of the gas control 3 Thread pipe the amount shown in Table 4 for inser tion into gas control Do not thread pipe too far Valve distortion or malfunction may result if the pipe is ins...

Страница 4: ...ply before making wiring con nections to prevent electrical shock or equipment damage 1 Checkthepowersupplyratingonthegascontroland assure it matches the available supply Install thermostat and other controls as required 2 When the gas control is installed external to the appliance install the conduit cover on the conduit fitting Do not secure conduit cover at this time 3 Connect control circuit t...

Страница 5: ...Inches Meters Inches Meters Inches Meters 12 0 3 47 1 2 30 0 8 18 0 5 18 0 5 41 1 0 26 0 7 16 0 4 24 0 6 35 0 9 22 0 6 14 0 4 30 0 8 29 0 8 18 0 5 11 0 3 36 0 9 23 0 6 15 0 4 9 0 2 40 1 0 19 0 5 12 0 3 7 0 2 48 1 2 11 0 3 7 0 2 60 1 5 Do not use Fig 7 Installing thermocouple to the power unit Fig 8 Wiring connections for 120 volt control 5 69 0683 1 120V THERMOSTAT POWER SUPPLY PROVIDE DISCONNECT ...

Страница 6: ...ascontrolknobdownaboutoneminute then release If the pilot flame goes out turn the gas control knob clockwise to OFF and repeat steps 1 through 3 If pilot flame remains lit turn the gas control knob counterclockwise to ON ADJUST THE PILOT BURNER FLAME The pilot flame should envelop 3 8 to 1 2 inch 10 to 13 millimeters of the thermocouple tip Refer to Fig 9 To adjust the pilot flame 1 Remove the pil...

Страница 7: ...er operation 4 If desired outlet pressure or flow rate cannot be achieved by adjusting the gas control check the inlet pressure using a manometer at inlet pressure tap or up stream of the gas control If the inlet pressure is in the normalrange refertoTable7or8 replacetheexistinggas control Otherwise take the necessary steps to provide proper gas pressure to the gas control 5 Carefully check main b...

Страница 8: ...e energizing step opening model to assure lightoff at step pressure IFTHEPILOTBURNERFLAMEWILLNOTLIGHT 1 Assure the main gas supply valve is open and the pilot gas supply line is purged of air 2 Attempt to light pilot burner flame following proce dures in Light the Pilot Burner Flame page 6 If pilot burner flame still will not light a Check the pilot gas adjustment screw If closed readjust the pilo...

Страница 9: ...c power to the appliance 3 Remove the gas control access panel 4 Push in the gas control knob slightly and turn clock wise to OFF NOTE The gas control knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force the gas control knob 5 Wait five minutes to clear out any unburned gas If you then smell gas STOP Follow step 3 in the Warnings above If you do not smell gas contin...

Страница 10: ...nd Building Control Helping You Control Your World Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley Minnesota 55422 Scarborough Ontario M1P 2V9 QUALITY IS KEY Printed in U S A ...

Отзывы: