Honeywell Vista Automation Module Скачать руководство пользователя страница 6

– 6 –

 

 

Software Upgrades 

Software upgrades may be available for this product. These 
upgrades can be installed manually, or you can set VAM to notify 
you that an upgrade is ready and have it automatically installed. 

System Information  

To view the current software version installed on your system, do 
the following:  Click 

Setup >

 

System Info

 

Automatic Software Updates 

To receive automatic remote updates, select the 

Enable Remote 

Update

 checkbox on the system information screen and install an 

SD card. 

 

1.  Click 

Setup

 > 

System Info,

 then select the 

Enable Remote 

Upgrade

 checkbox. 

2.  Make sure a blank SD card is installed (minimum 200 MB of 

available space is required. 

3.  When updates are available, the system will automatically 

update the system. 

 
 

Manual Software Upgrades 

Go to the Toolkit site located at:  

http://www.tuxedotouchtoolkit.com/index.html

 

to download the 

latest software to an SD card. 

1.  Copy the software upgrade file to the SD card. 

2.  Insert the SD card and recycle power on the VAM (or press the 

Reset button using a paper clip). The yellow Operation LED 
flashes during the upgrade process. 

3.  The LEDs show solid green and blue indicating the 

default/upgrade process is done. 

 

 
 
 

Set Up Remote Access (Account Setup) 

Remote access lets the user access VAM’s menus directly via 
the Internet when away from home. The home router must first 
be configured for port forwarding. Refer to the router’s 
instructions for details on port forwarding. 
To set up a remote access log in, do the following: 
1.  Click 

Setup

 > 

Account

2.  Enter the desired user name and password. Passwords must 

be a minimum of 8 alphanumeric characters, and must 
include at least one uppercase, one lowercase, and one 
number. 

3.  Click 

Save

. The new user is displayed. 

 

To clear a user’s login, click the 

CLEAR

 button. 

 

To access VAM remotely, use a web browser and VAM’s 
network IP address to go to the login screen. Enter the assigned 
user name and password to open the main menu. 

NOTE:

 Remote login is blocked after 3 failed attempts. To reset 

remote  access,  you  must  connect  to  VAM  locally  via  the  home 
router,  then  re-enable  remote  access.  Click 

Setup

  > 

Account

then click the appropriate 

Enable

 button and click 

Save

 
 

Options 

IMPORTANT

: This menu is intended for the installer only and 

should not be changed by the user.  

Options include the following: 

Normal mode:  For use when VAM is connected to a VISTA 

control panel. 

Demo mode:   For use in the event a VISTA security system is 

unavailable. Selecting Demo mode disconnects 
communication between the VAM and the VISTA 
control panel, but otherwise VAM can be used to 
control Z-Wave devices and perform its other 
non-security related functions. 

 

 
 

Содержание Vista Automation Module

Страница 1: ...it does use a supplementary power supply as shown IMPORTANT When VAM is powered from an auxiliary power supply always apply power to the control panel first and then VAM Failure to observe this sequence results in improper operation of VAM and may result in an ECP Error indication pwr_supp_conn 011 V0 BLACK POWER FROM SUPPLEMENTARY POWER SUPPLY IF USED RED BLACK GREEN YELLOW CONTROL TERMINAL STRIP...

Страница 2: ...teps must be repeated to connect the VAM to the new router 1 Connect a smart device to VAM a Power up the VAM b Connect the smart device to the VAM using the device s WiFi settings menu VAM is a wireless access point Enter the VAM SSID VAM_xxxx SSID is case sensitive NOTE xxxx the last 4 digits of the MAC address Enter the Key found on the VAM label WPA2 pw line 2 Access VAM s home screen a Open a...

Страница 3: ...e or more selected system events or conditions occur NOTE Email notification requires that the user has an active email address 1 Click Setup then select Email 2 Click User SMTP to assign the user s email server information SMTP establishes the email server domain the from address a Choose the email server name email provider from the drop down menu Choose from GMAIL OUTLOOK YAHOO or Add New b Ent...

Страница 4: ...on to 320 x 240 8 frames per sec Normal quality 5 Click the Add button if the camera information is not discovered automatically to enter information manually 6 To edit camera information highlight the camera name and click the Edit button Enter required information and then click Save Automation Creating Scenes The system can automatically activate various devices when certain events occur based ...

Страница 5: ...l Z wave devices have been tested and some features may produce unpredictable results Using VAM as a Secondary Controller VAM can be used as a secondary controller when connected to another Z Wave network 1 Remove any Z Wave devices previously included in VAM Click Automation Z Wave Setup to display the Z Wave Management screen then click Z Wave Default and select Yes 2 Press the Z Wave Primary bu...

Страница 6: ...te access lets the user access VAM s menus directly via the Internet when away from home The home router must first be configured for port forwarding Refer to the router s instructions for details on port forwarding To set up a remote access log in do the following 1 Click Setup Account 2 Enter the desired user name and password Passwords must be a minimum of 8 alphanumeric characters and must inc...

Страница 7: ...n for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet Appareil numérique de la classe B est conforme à la norme NMB 003 du Canada FEDERAL COMMUNICATIONS COMMISSION FCC PART 15 This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause har...

Отзывы: