Honeywell VisionPRO TH8110U Скачать руководство пользователя страница 7

TH8110U TOUCH SCREEN PROGRAMMABLE THERMOSTATS

7

69-1700

Exiting Installer Setup

1.

Press Done key to exit Installer Setup screen.

IMPORTANT

The three Installer Setup Menus (Tables 4-6) 
show all available options. These options cus-
tomize themselves as you make selections to 
Installer Setup. So not all Installer Setup 
Selections are shown or are available to 
change.

Table 4. Main Installer Setup Menu.

Select

Installer 

Setup 

Number

Factory Setting

Other Choices

Comments

Option

Description

Options

Description

Not used.

1 thru 0099 —

 —

Date (Year 
Upper)

0120

20

Set first two digits of 
current calendar 
year (20 for year 

20

05, etc)

21

21 —first two digits of 
current calendar year (21xx)

2000 -2178 
available

Date (Year 
Lower)

0130

04

Represents last two 
digits of current 
calendar year 
(20

04

).

00 -99

Select last two digits of 
current calendar year.

2001-2178 
available

Date (Month) 0140

6

Digit(s) represents 
current calendar 
month.

1-12

Select number that 
represents current calendar 
month.

 —

Date 
(Day)

0150

15

Digit(s) represents 
current calendar 
date.

1-31

Select number that 
represents current calendar 
date.

Schedule 
Options

0160

4

7-day programming 0

0 —nonprogrammable 

 —

System Type 
Selection

0170

1

1 Heat/1 Cool 
Conventional 
System

1-6

1—1 heat/1 cool
2—single-stage heat pump 
(no aux. heat)
3—heat only (no fan)
4 —heat only (with fan)
5—hot water Series 20 
(3-wire or normally open 
zone valves)
6—cool only

Available options 
and defaults vary 
by thermostat. 
System selection 
automatically 
modifies some 
default settings 
and/or hides other 
Installer Setup 
options.

Fan Operation  0180

0

Conventional 
applications where 
equipment controls 
fan operation in 
heat mode.

1

Heat pump or electric heat 
applications where 
thermostat controls fan 
operation in heat mode.

Only shown if 
conventional 
system is 
selected. If heat 
pump is chosen, 
fan defaults to 
electric.

Reversing 
Valve (O/B) 
Operation

0190

0

O/B terminal is 
energized for 
reversing valve in 
cooling

1

O/B terminal is energized for 
reversing valve in heating

Only shown if 
heat pump 
system is chosen.

Содержание VisionPRO TH8110U

Страница 1: ...tion 2 Check the ratings given in the instructions to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation Selecting Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fi...

Страница 2: ...et of terminal identifications Table 2 that corresponds with system type conventional or heat pump in Fig 3 2 Loosen the screws for the appropriate system type selected see Table 2 Insert wires in the terminal block under the loosened screw See Fig 4 3 Securely tighten each screw 4 Push excess wire back into the hole 5 Plug the hole with nonflammable insulation to prevent drafts from affecting the...

Страница 3: ...ELAY FAN RELAY R C POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED REMOVE FACTORY INSTALLED JUMPER OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR AVAILABLE ON SELECT MODELS WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE 1 1 3 2 3 OPTIONAL 24 VAC COMMON CONNECTION Y2 RC S1 R S2 W W2 Y G C 2 CONVENTIONAL M19897 OUTDOOR INDOOR TEMPERATURE SENSOR HEAT RELAY R C POWER SU...

Страница 4: ...9899 OUTDOOR INDOOR TEMPERATURE SENSOR POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED FACTORY INSTALLED JUMPER OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR AVAILABLE ON SELECT MODELS WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE 1 3 2 3 Y2 RC S1 R S2 W W2 Y G C 2 CONVENTIONAL R TR C 1 TR W B R SERIES 20 MOTOR OR VALVE M19900 OUTDOOR INDOOR TEMPERATURE SENSOR FAN...

Страница 5: ...splay is ready to enter calendar date Fig 15 Fig 15 Setting calendar and time after initial powerup IMPORTANT The tab on back of thermostat in lower left corner must be removed to activate this feature Using the Thermostat The thermostat has a touch screen interface Words or symbols appear highlighting keys as needed to complete tasks Press keys with your fingertips Sharp tips on pens or pencils c...

Страница 6: ...ering Installer Setup 1 Thermostat must be powered either with Alkaline AAA batteries or with 24 Vac Common wire 2 From the home screen press System key Press Done or Cancel key to return to home screen 3 Five blank touch keys show on the bottom of the screen between the Done and Cancel keys Press and hold the two blank keys on either side of the center blank key for approximately five seconds unt...

Страница 7: ...h 1 12 Select number that represents current calendar month Date Day 0150 15 Digit s represents current calendar date 1 31 Select number that represents current calendar date Schedule Options 0160 4 7 day programming 0 0 nonprogrammable System Type Selection 0170 1 1 Heat 1 Cool Conventional System 1 6 1 1 heat 1 cool 2 single stage heat pump no aux heat 3 heat only no fan 4 heat only with fan 5 h...

Страница 8: ...ge changes default cph for 2nd stage heat Continuous Backlight 0280 0 Backlight not on continuously Thermostat backlight comes on with each key press 1 Backlight is on continuously thermostat must have a common wire attached for this function Option is always shown however continuously on backlight works only if thermostat is wired with 24 vac Common Additional Menu Choices 0290 0 Only main menu o...

Страница 9: ... 5 F 3 C 6 6 F 3 5 C 7 7 F 4 C 8 8 F 4 5 C 9 9 F 5 C Shown only if automatic changeover is selected Temperature Indication Scale 0320 0 Temperature is displayed in F 1 Temperature is displayed in C Daylight Savings 0330 1 Daylight savings enabled United States 0 0 daylight savings is disabled Set to 0 in areas that do not follow daylight savings Remote Temperature Sensor Outdoor or Indoor 0340 0 N...

Страница 10: ... 0540 4 Four periods available Wake Leave Return Sleep 2 Two periods availbable Wake and Sleep Not shown in non programmable is selected 2 or 4 applies to all days of the week Minimum Compressor Off Time 0580 5 Five minute minimum off time for compressor 0 2 3 4 Minimum number of minutes compressor is off between calls for compressor Heat Temperature Range Stop 0600 90 Highest heating setpoint 40 ...

Страница 11: ...Standard temperature control in heating 1 3 1 less aggressive temperature control could cause temperature undershoot 3 more aggressive temperature control could cause temperature overshoot Applies to recovery ramp and use of auxiliary heat during recovery Choose 1 if getting temperature overshoot Choose 3 if getting temperature undershoot Temperature Control in Cool 0690 2 Standard temperature con...

Страница 12: ...heck for 24 Vac between C and Rc Verify AAA batteries installed correctly and good Temperature settings do not change The upper or lower temperature limits were reached Check temperature setpoints Check Installer Setup Numbers 0600 and 0610 modify The keypad is fully locked Check Installer Setup Number 0670 to change keypad lock options Heating or cooling does not come on Thermostat minimum off ti...

Отзывы: