69-0329—4
8
Home and Building Control
Home and Building Control
Helping You Control Your World
Honeywell Inc.
Honeywell Limited—Honeywell Limitée
1985 Douglas Drive North
740 Ellesmere Road
Golden Valley, MN 55422
Scarborough, Ontario
M1P 2V9
Printed in U.S.A.
QUALITY IS KEY
3. Remove burner access panel if provided on your
appliance.
4. Turn the gas control knob (Fig. 4) clockwise
to OFF.
5. Wait five minutes to allow any gas in the combustion
chamber to vent. If you smell gas in the appliance area or
near the floor in an LP installation, immediately shut off the
manual valve in the gas piping to the appliance or, on LP, at
the tank. Don’t touch any electrical switch or use the phone.
Leave the building and call your gas supplier. If your gas
supplier cannot be reached, call the fire department. Failure
to do so may result in fire or explosion.
6. If you don’t smell gas, turn knob on gas control
counterclockwise
to ON.
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the burner does not come on when the room
temperature is below thermostat setting, turn gas control
knob to OFF and contact a qualified service technician for
assistance.
TO TURN OFF APPLIANCE
Turn the gas control knob clockwise
to OFF.