Technical features 

UCIP / UCIP GPRS Default Settings 

Status LEDs: 

ALRM1 

DL1-RED 

- EXISTING DATA WITH CRA 

ALRM2 

DL2 RED 

- EXIXTING DATA WITH PANEL 

ALRM3 

DL3-RED 

-GPRS BIDIRECTIONALITY ACTIVE 

ALRM4 

DL4-RED 

-TCP/IP BIDIRECTIONALITY ACTIVE 

BLINK 

DL5-GREEN 

SOFTWARE WORKING 

ON: Powered inactive process 

Slow blinking : Process running OK 

Off: Inoperative Process 

 

COBER 

DL6- BICOLOR 

GSM Coverture 

GREEN MAXIMUM COVERTURE 

ORANGE MEDIUM COVERTURE 

RED LOW COVERTURE 

BLINK GPRS SERVER CONNECTED 

TX MOD 

DL7-GREEN 

GSM MODEM CONNECTED 

GPRS / GSM activity 

ON: Modem Active(Calling) 

IND01 

DL9 

– GREEN 

OUTPUT 1 STATE ( Off means CRA link failure , after 5 retries) 

IND02 

DL8 - GREEN 

OUTPUT 2 STATE (Off means Panel link fault) 

 

 
TECHNICAL FEATURES: 

 

Power 

12 a 30 Vdc (not polarized) external or via Aux port 

Current 

45mA min / 150mA max.  

Communication Ports 

1 x RS232 (Rx,Tx GND from 1200 to 115200 Bds) 

1 x Ethernet (ADSL, LAN, etceteras...)  

1 x Modem GSM (GSM, SMS, GPRS) 

1 x I2C double connector and power 

1 x RS485 

Configuration 

Terminal console commands / Telnet over Ethernet and GPRS. Permits SMS message commands. 

Serial port 232 

Rx,Tx y GND. Configurable speed and parity (1200 to 115200 Bds) 

Compatible Panels with SMS or Contact ID 

NFS Supra, Vision Plus, Vision 2Plus, ID50, ID3000 and DXC CONNEXION 

CRA Protocol and security 

Double channel de transmission over Ethernet and GPRS  

Connectivity checking  (stay alive) and bidirectionality.   

Ademco Contact ID protocol IP/GPRS to CRA over ALWON 128 encrypted AES128 compatible 
protocol. Communicator switch security and config password key. 

IP Connectivity 

DNS compatible, DHCP and dynamic IP (IP update by alive string) 

Firmware update 

Via RS232 or GPRS by UCIP Consola Tool 

Dimensions (w.o. box) 

86mm height x102mm width x25mm depth 

Enclosure Dimensions 

102mm height x143mm width x39mm depth 

Approvals 

EN50136 SPT 1-6, Type X/Y 

 
REQUIRED DATA TO CONNECT THE DEVICE: 

For Ethernet: 

UCIP IP in local network 

 

Local Mask + Gateway 

 

For GPRS: 

APN GPRS net name 

 

User 

 

Password 

 

SIM card PIN (or remove) 

 

To a CRA: 

Client Number/code 

 

CRA IP 

 

IP port 

 

ALIVE time 

 

Encryptation password 

 

Information for the CRA 

UCIP Production Serial #  

S/N: 

Protocol UCIP 

Honeywell R TCPv9.0.2;R20;Lopez Bellov9.0.2 Receiver - Protocol Alwon 128 (Contact ID) 

 
 

 
 

 

INFORMACIÓN DE PRODUCTO

 
The UCIP and UCIP-GPRS Communicator permits to connect panels via IP by Ethernet or/and GPRS. 
UCIP/UCIP GPRS is compatible to connect to an IP Central Receiver Alarm center the Honeywell Fire Alarm Panels: Notifier:ID3000, 
ID50, NFS Supra; Morley-IAS: CONNEXION, VSN-2Plus and ESSER: ESS-2PLUS.  
 
UCIP-GPRS is shipped to be connected to the Honeywell GPRS APN to be linked to the FireIMT online server and associated services. 
 
When UCIP is connected to he compatible panels it recognizes the panel protocol and its serial port is automatically set to communicate 
with it. SIM card is detected at the device start up to start the GPRS modem. In some panels it is necessary to configure the Integration 
protocol. 
The UCIP SERIAL NUMBER is different on each device and must be indicated to the Central Alarm Receiver center to configure client. 

 

DEFAULT SETTINGS: 

Default settings includes: 
-

Serial Port

 to Fire panel link  : 9600 Baud, no parity, to panel port RS232 or TTL (depending on port Jumpers). 

-

GPRS Network

: SIM is required, configured to connect to Fire IMT server (port 5000) Requires SIM card provibed by Honeywell and 

client settings) 
-

ETHERNET

 to remote link by port 5000 (TG):  

IP UCIP: 192.168.0.100, Mask 255.255.255.0, Gateway 192.168.0.1, Ethernet port: 5000  
-

CRA

: Requires CRA IP address configuration, by default sends System Alarm and Fault by zones state. 

-

SMS

: SIM is required. No phone is configured: Sends complete information and device labels configured in the ID and DXc panels. 

Configuration checking: 

The device configuration can be checked by using the CONFIG command connected to device in the configuration mode. 

>config 

SERIAL NUMBER- 

xxxxxxx

 

CRA1- Suscriber:, IP:0.0.0.0, Puerto:0, Alive:0, Key:, Channel:GPRS+ETH 
CRA2- Suscriber:, IP:0.0.0.0, Puerto:0, Alive:0, Key:, Transmission: On fail of CRA 1; Channel:GPRS+ETH 
SMS/DAY- Without limit ,Send: 0 
TCP/IP- MAC:00-04-A4-01-00-05, IP:192.168.0.100, Mask:255.255.255.0, Gateway:192.168.0.1, DHCP:ON, Host:E20_5           
TELNET- Port:23 
UART1- Speed:9600, Parity:NONE 
I2C- Local Address:40, Remote Address:0 
RS485-Local Address:3, Remote Address:0 
UDP-Address:0.0.0.0, Port:1 
TCP SERVER-Port:5000 
TCP CLIENT-Address:0.0.0.0, Port:1 
GPRS- wlapn.com, User: honeywell, Password: honeywell 
GPRS SOCKET-NONE 
GPRS SERVER- Local Address:0.0.0.0, Local Port:5000 
SMS ALARM- CRA:, User1:, User2: 

 
Configuration commands: 

CRA1

 ACCOUNT IPADDRESS PORT ALIVE KEY: Configure the CRA account number, central IP,key and Alive period 

CRA2

 ACCOUNT IPADDRESS PORT ALIVE KEY TRANSMISSION: Configure the CRA2 account number, central IP,key and Alive period 

CONFIG

 PORT PARAM1 PARAM2:Config Port or display configuration 

EVENT

 EVENT CODE: Config ContactID event codes 

EVENTNAME

 EVENT NAME: Config event name 

EXIT

 :Exit program console 

FAULT

 FAULT CODE: Config fault codes 

GSM

 Modem GSM Communication console 

GPRS

 APN USER PASSWORD:Config GPRS network 

INI

 :Reset configuration (no borra IP ETH) 

OUT

 OUTPUT STATUS TIMER: Enable or disable digital output 

PIN

 PIN: SIM PIN settings 

RESET

 System Reset, Cold start 

SMS

 CENTRAL_PHONE USER_PHONE1 USER_PHONE2 MAXSMS: SMS parameters configuration 

TCPIP

 ADDRESS MASK GATEWAY DHCP:Config TCP/IP 

ZONE

 ZONE SENSOR MODULE FAULT DISABLE:Config zone event codes 

ZONENAME

 ZONE NAME: Config zone name 

TCPIP

 INI : Set default IP. The INI command does not change device IP. 

CRA

X OFF: Erase CRA X(1 o 2) settings 

 

Note

: Before to install the system, check and read carefully device  

and connected panel manuals and don’t  make any action before to understand them.  