T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

5

69-1415—1

Fig. 8. T8611M System and Fan key locations.

LED Indication

Two LED indicators are located in the upper right of the 
thermostat. They indicate when a CHECK or FAIL signal 
is sent to the thermostat from the system. See Fig. 9. The 
CHECK LED is on continuously when the thermostat 
system setting is in the Emergency Heat position.

.

Fig. 9. LED location.

Temperature Settings

Refer to Table 2 for the default program settings. If the 
daytime energy savings period is not used, press the 
period key (Leave or Return) until the time is blank. The 
fan setting feature is available on select thermostat 
models. See Owner’s Guide for complete instructions on 
changing the program.

Table 2. Default Program Settings.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings will not need to be changed. Review 
the factory settings in Table 2 and if no changes 
are necessary, go to the Installer System Test 
section.

The Installer Setup is used to customize the thermostat 
to specific systems. Some of the options include 
temperature display, changeover and outdoor 
temperature display. Installer Setup numbers are listed in 
Table 3. The table includes all the configuration options 
and the factory settings for the T8611. 

A combination of key presses are required to use the 
Installer Setup feature:
— To enter the installer setup, press and hold the 

information 

i

 key with the increase 

s

 and decrease 

t

 

keys until the first number is displayed. All display 
segments appear for approximately three seconds 
before the number is displayed. See Fig. 10 and 11.

— To advance to the next Installer Setup, press the 

Time 

 key.

— To change a setting, use the increase 

s

 or 

decrease

 t 

key.

— To scroll the Installer Setup numbers backward, press 

the Time 

 key.

— To exit the Installer Setup, press Run Program.

Fig. 10. Display of LCD segments.

Fig. 11. Display of Installer Setup 

number and setting.

IMPORTANT

Only configurable numbers are shown on the 
device. Example: If thermostat does not have a 
system key, Installer Setup Number 12 will not 
be displayed. Review Table 3 factory settings 
and mark any desired changes in the Actual 
Setting column. When Installer Setup is 
complete, review the settings to confirm that 
they match the system.

Period

Time

Heat 

Setpoint

Cool 

Setpoint

Fan 

Setting

Wake

6:00 AM

70°F

(21°C)

78°F

(25.5°C)

Auto

Leave

8:00AM

62°F

(16.5°C)

85°F

(29.5°C)

Auto

Return

5:00 PM

70°F

(21°C)

78°F

(25.5°C)

Auto

Sleep

10:00 PM

62°F

(16.5°C)

82°F

(28°C)

Auto

M14625

Hold Temp

Run

Program

Copy

Daylight

Time

Set Current

Day/Time

System

Fan

Time

Set Program

Day

System

Fan

Wake

Leave

Return

Sleep

Heat/Cool

Settings

M10675A

TWO LED INDICATORS

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

System

Fan

Em Heat

On

Auto

Off

Cool
Auto

AM

PM

Hold for

Heat

Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary

Setting

Em Ht

M14618

INSTALLER SETUP

NUMBER DISPLAY

(COLUMN 2 OF TABLE 3)

FACTORY SETTING OR OTHER 

CHOICE DISPLAY (COLUMN 3

OR 5 OF TABLE 3)

Содержание Tradeline T8611M

Страница 1: ...er disposal of the old control INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow the instructions can damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing...

Страница 2: ...hen not level 2 Use a pencil to mark the mounting holes See Fig 2 3 Remove the wallplate from the wall and drill two 76 mm 3 16 inch holes in the wall if drywall as marked For firmer material such as plaster drill two 5 56 mm 7 32 inch holes Gently tap anchors provided into the drilled holes until flush with the wall 4 Position the wallplate over the holes pulling wires through the wiring opening ...

Страница 3: ...R C7089B1000 AND CONFIGURE INSTALLER SETUP NUMBER 24 TO 1 BE SURE INSTALLER SETUP NUMBER 3 IS SET TO 2 FOR TWO COMPRESSOR SYSTEMS WIRE EQUIPMENT MONITOR OR DEFROST RESET CONTROL PER MANUFACTURER INSTRUCTIONS CONFIGURE IN INSTALLER SETUP 1 AUX HEAT RELAY M13289 COMPRESSOR CONTACTOR 1 FAN RELAY R OT OT O B G Y1 C E W3 OUTDOOR TEMPERATURE SENSOR COOL HEAT CHANGEOVER VALVE EM HEAT RELAY THERMOSTAT 1 2...

Страница 4: ... cycles the Emergency Heat relay and the highest heat stage Cooling system is off Compressor is de energized Heat The thermostat controls the heating Off Both the heating and cooling are off Cool The thermostat controls the cooling Auto The thermostat automatically changes between heating and cooling operation depending on the indoor temperature Fan settings control the system fan On Fan operates ...

Страница 5: ...on i key with the increase s and decrease t keys until the first number is displayed All display segments appear for approximately three seconds before the number is displayed See Fig 10 and 11 To advance to the next Installer Setup press the Time key To change a setting use the increase s or decrease t key To scroll the Installer Setup numbers backward press the Time key To exit the Installer Set...

Страница 6: ...isplay 14 0 Temperature is displayed in F 1 Temperature is displayed in C Not Used 15 Clock format 16 0 12 hour clock format 1 24 hour clock format Not Used 17 thru 18 Extended fan operation in heating 19 0 No extended fan operation after the call for heat ends 1 Fan operation is extended 90 seconds after the call for heat ends Extended fan operation in cooling 20 No extended fan operation after t...

Страница 7: ... adjustment 37 0 No difference in displayed temperature and actual room temperature 3 thru 3 1 Display adjusts to 1 F higher than actual room temperature 2 Display adjusts to 2 F higher than actual room temperature 3 Display adjusts to 3 F higher than actual room temperature 1 Display adjusts to 1 F lower than actual room temperature 2 Display adjusts to 2 F lower than actual room temperature 3 Di...

Страница 8: ...System Test Avoid cycling compressor quickly To start the system test Press and hold the increase s and decrease t keys at the same time until 10 appears All segments of the display are displayed before the 10 appears See Fig 12 and 13 Table 4 Tests Available In Installer System Test M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Retur...

Страница 9: ...ing Equipment System Test Time 10 Enter heating equipment system test s 11 Stage one heat comes on The system fan is also energized s 12 Stage two heat comes on Stage one heat and system fan remain on s 13 Stage three heat comes on Stage one and two remain on t 12 Stage three heat turns off t 11 Stage two heat turns off t 10 Stage one heat and system fan turn off Emergency Equipment Heating Equipm...

Страница 10: ...re identification code Example 02 software ID code 2 4 Press the increase s key again to display the software revision number Example 001 Revision number 1 5 Press the increase s key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the System Test The System Test times out after four minutes without any key presses CHECKOUT Outdoor Tempe...

Страница 11: ...power to the thermostat Check for 24 Vac between R and W terminals If missing 24 Vac check if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten any loose connec...

Страница 12: ... or cool air is coming from the registers Heating or cooling equipment is not operating Verify operation of heating or cooling equipment in self test Outdoor tempera ture not displayeda Option not activated Enter Installer Setup number 24 and set to 1 Thermostat must have OT terminals and a C7089B1000 installed Outdoor temperature display is incorrecta Outdoor sensor is connected incorrectly Refer...