Mounting Thermostat

1.

Engage tabs at the top of the thermostat and 
wallplate. See Fig. 6.

2.

Press lower edge of case to close and latch.

NOTE: To remove the thermostat from the wall, first pull 

out at the bottom of the thermostat; remove top 
last.

Using Thermostat Keys

The thermostat keys are used to:
• set current day and time,
• program times and setpoints for heating and cooling,
• temporarily override program temperatures, 
• display present setting, 
• configure Installer Setup, 
• check System Test,
• display outdoor temperature (select models),
• set the system operation, 
• set the fan operation. 

See Fig. 7 for the key location.

NOTE: Always press the keys with your fingertip or 

similar blunt tool. Sharp instruments like a pen 
or pencil point can damage the keyboard.

Fig. 6. Mounting thermostat on wallplate.

Fig. 7. T8611M key locations and descriptions.

SETTINGS

System and Fan Settings 

The system default setting is Heat and the fan default 
setting is Auto. Use the System and Fan keys to change 
the settings. See Fig. 8. The fan settings can be set for 
each program period individually. The system selection is 
for all the program periods.

System settings control the thermostat operation:

Em Heat: Defrost reset output relay (L) is on 

continuously. The thermostat cycles the 
Emergency Heat relay and the highest heat stage. 
Cooling system is off. Compressor is de-energized.

Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between 

heating and cooling operation, depending on the 
indoor temperature.

Fan settings control the system fan:

On: Fan operates continuously.
Auto: Fan operates with equipment.

M14634

PRESS LOWER 

EDGE OF CASE 

TO LATCH.

ENGAGE TABS 

AT TOP OF 

THERMOSTAT 

AND WALLPLATE.

A.

B.

M14624

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

INCREASE TEMPERATURE 
SETTING OR SCROLL 
FORWARD THROUGH 
INSTALLER SETUP OPTIONS

DECREASE TEMPERATURE 
SETTING OR SCROLL 
BACKWARD THROUGH 
INSTALLER SETUP OPTIONS

DISPLAY INFORMATION
SUCH AS PRESENT 
SETTINGS AND OUTDOOR 
TEMPERATURE

RETURN TO 
NORMAL
OPERATIONS

ENTER 
INDEFINITE 
OR TIMED 
HOLD MODE

SET CURRENT 
DAY AND TIME

SET CURRENT OR
PROGRAM DAY

CHANGE BETWEEN 
DAYLIGHT SAVINGS 
AND STANDARD TIME

INCREASE TIME SETTING
OR SCROLL FORWARD 
THROUGH INSTALLER SETUP 
AND SYSTEM TEST

DECREASE TIME SETTING OR 
SCROLL BACKWARD THROUGH 
INSTALLER SETUP AND SYSTEM TEST

COPY ONE PROGRAMMED 
DAY TO ANOTHER DAY

SET WAKE TIMES 
AND SETPOINTS

CHANGE BETWEEN 
HEATING AND COOLING 
SETPOINTS 

SET LEAVE TIMES 
AND SETPOINTS

SET RETURN TIMES 
AND SETPOINTS

SET SLEEP TIMES 
AND SETPOINTS

SELECT SYSTEM 
OPERATION 

SELECT FAN 
OPERATION 

Содержание Tradeline T8611M

Страница 1: ...er disposal of the old control INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow the instructions can damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing...

Страница 2: ...hen not level 2 Use a pencil to mark the mounting holes See Fig 2 3 Remove the wallplate from the wall and drill two 76 mm 3 16 inch holes in the wall if drywall as marked For firmer material such as plaster drill two 5 56 mm 7 32 inch holes Gently tap anchors provided into the drilled holes until flush with the wall 4 Position the wallplate over the holes pulling wires through the wiring opening ...

Страница 3: ...R C7089B1000 AND CONFIGURE INSTALLER SETUP NUMBER 24 TO 1 BE SURE INSTALLER SETUP NUMBER 3 IS SET TO 2 FOR TWO COMPRESSOR SYSTEMS WIRE EQUIPMENT MONITOR OR DEFROST RESET CONTROL PER MANUFACTURER INSTRUCTIONS CONFIGURE IN INSTALLER SETUP 1 AUX HEAT RELAY M13289 COMPRESSOR CONTACTOR 1 FAN RELAY R OT OT O B G Y1 C E W3 OUTDOOR TEMPERATURE SENSOR COOL HEAT CHANGEOVER VALVE EM HEAT RELAY THERMOSTAT 1 2...

Страница 4: ... cycles the Emergency Heat relay and the highest heat stage Cooling system is off Compressor is de energized Heat The thermostat controls the heating Off Both the heating and cooling are off Cool The thermostat controls the cooling Auto The thermostat automatically changes between heating and cooling operation depending on the indoor temperature Fan settings control the system fan On Fan operates ...

Страница 5: ...on i key with the increase s and decrease t keys until the first number is displayed All display segments appear for approximately three seconds before the number is displayed See Fig 10 and 11 To advance to the next Installer Setup press the Time key To change a setting use the increase s or decrease t key To scroll the Installer Setup numbers backward press the Time key To exit the Installer Set...

Страница 6: ...isplay 14 0 Temperature is displayed in F 1 Temperature is displayed in C Not Used 15 Clock format 16 0 12 hour clock format 1 24 hour clock format Not Used 17 thru 18 Extended fan operation in heating 19 0 No extended fan operation after the call for heat ends 1 Fan operation is extended 90 seconds after the call for heat ends Extended fan operation in cooling 20 No extended fan operation after t...

Страница 7: ... adjustment 37 0 No difference in displayed temperature and actual room temperature 3 thru 3 1 Display adjusts to 1 F higher than actual room temperature 2 Display adjusts to 2 F higher than actual room temperature 3 Display adjusts to 3 F higher than actual room temperature 1 Display adjusts to 1 F lower than actual room temperature 2 Display adjusts to 2 F lower than actual room temperature 3 Di...

Страница 8: ...System Test Avoid cycling compressor quickly To start the system test Press and hold the increase s and decrease t keys at the same time until 10 appears All segments of the display are displayed before the 10 appears See Fig 12 and 13 Table 4 Tests Available In Installer System Test M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Retur...

Страница 9: ...ing Equipment System Test Time 10 Enter heating equipment system test s 11 Stage one heat comes on The system fan is also energized s 12 Stage two heat comes on Stage one heat and system fan remain on s 13 Stage three heat comes on Stage one and two remain on t 12 Stage three heat turns off t 11 Stage two heat turns off t 10 Stage one heat and system fan turn off Emergency Equipment Heating Equipm...

Страница 10: ...re identification code Example 02 software ID code 2 4 Press the increase s key again to display the software revision number Example 001 Revision number 1 5 Press the increase s key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the System Test The System Test times out after four minutes without any key presses CHECKOUT Outdoor Tempe...

Страница 11: ...power to the thermostat Check for 24 Vac between R and W terminals If missing 24 Vac check if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten any loose connec...

Страница 12: ... or cool air is coming from the registers Heating or cooling equipment is not operating Verify operation of heating or cooling equipment in self test Outdoor tempera ture not displayeda Option not activated Enter Installer Setup number 24 and set to 1 Thermostat must have OT terminals and a C7089B1000 installed Outdoor temperature display is incorrecta Outdoor sensor is connected incorrectly Refer...

Отзывы: