The T8024 Programmable Multistage Thermostat 

provides electronic control of single-zone, multistage 
heating and cooling systems. First stage and second 

stage cooling cycle rates are fixed at 3 cph. Heating 
cycle rate is selectable. Temperature indication can be 

set for °F or °C.

The T8024 Thermostat is powered from the system 
transformer. Batteries are not required because setpoints 

are held permanently by non-volatile memory.

T8024 includes a thermostat, wallplate (for wiring and 
mounting thermostat) and owner’s guide. 

MERCURY NOTICE

If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 

control in the trash.

Contact your local waste management authority 
for instructions regarding recycling and the 

proper disposal of an old control containing 
mercury in a sealed tube.

If you have questions, call Honeywell Inc. at 

1-800-468-1502.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-

ous condition.

2.

Check the ratings given in the instructions and on 

the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

CAUTION

Electrical Shock or Equipment Damage 
Hazard.

Can shock individuals or short equipment 
circuitry.

Disconnect power supply before installation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in 
an area with good air circulation at average temperature. 

See Fig. 1. Do not install the thermostat where it can be 
affected by:

— drafts or dead spots behind doors and in corners.
— hot or cold air from ducts.

— radiant heat from the sun or appliances.
— concealed pipes and chimneys.

— unheated (uncooled) areas such as an outside wall 

behind the thermostat.

This thermostat is a precision instrument and was 

carefully adjusted at the factory. Handle it carefully.

Mounting Wallplate to Wall

IMPORTANT

Level only for appearance. The thermostat func-
tions normally even when not level.

Mount wallplate, T8024 and the screws provided (see 

Fig. 2) as follows:

1.

Place the wallplate at the desired location on the 

wall.

2.

Pull the thermostat wire through the entrance hole 

on the decorator cover plate, then through the wall-
plate entrance hole.

3.

Select the two mounting holes that best fit the 
application.

4.

Fasten the wallplate to the wall using the anchors 
and screws provided.

5.

After wiring the wallplate, plug the hole to prevent 
drafts from affecting the thermostat; see Wiring 

section.

Содержание Tradeline T8024D

Страница 1: ...duct is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation Location Install the thermostat about 5 ft 1 5m above the f...

Страница 2: ...e shape of the terminals permits insertion of straight or wraparound wiring connections either method is acceptable See Fig 4 The T8024 Thermostat is powered through the system transformer and is adaptable to most 24 Vac multistage heating cooling systems Refer to Fig 5 for typical wiring hookups Fig 3 Restrict wiring to shaded area 5 FEET 1 5 METERS YES NO NO NO M11338 M12202A WALL WALL ANCHORS 2...

Страница 3: ...nutes after the heating equipment turns on on most systems When using an electric heat thermostat the fan starts and stops with the heating equipment Slide the FAN switch in the bottom left corner of the thermostat to select the desired fan setting SYSTEM Switch System switch settings control thermostat operation as follows Cool The thermostat controls the cooling system Off Both heating and cooli...

Страница 4: ... 1d only pressing the key can be used to turn heat or cool outputs on and off Change the SYSTEM switch setting to test heat or cool outputs No action takes place If the system switch is in the Off position Examples System setting at HEAT If heat is on pressing the key turns it off if heat is off pressing the key turns it on System setting at COOL If cool is on pressing the key turns it off if cool...

Страница 5: ...ey to save all changes and return to normal operation Table 1 Heating Cycle Rates for Stage Two Heating a High efficiency furnace bRefer to equipment manufacturer s instructions PROGRAMMING The thermostat is flexible and can be programmed for different schedules for weekdays and weekends Four time periods are available during weekdays and weekends WAKE LEAVE RETURN and SLEEP IMPORTANT Always press...

Страница 6: ...C Refer to manufacturer s recommendations Allow compressor to remain off for five minutes before restarting 1 Slide the SYSTEM switch to Cool and the FAN switch to Auto 2 Press the key to lower the temperature setting several degrees below the room temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cool ing equipment 3 Press the key to...