Honeywell Titan SCBA Скачать руководство пользователя страница 9

3

Honeywell Titan SCBA, 2013

2

WARNING—CONTINUED

• ONLY grasp the cylinder valve handwheel 

to open or close the valve. DO NOT pick up 

or carry a cylinder by the handwheel, drop 

a  cylinder  on  the  handwheel,  or  bump  the 

handwheel, as this may cause the cylinder 

valve to inadvertently open, which may lead 

to the cylinder becoming airborne under the 

thrust of air released from the open valve, 

causing  injury  or  death.  ALWAYS  pick  up 

and  carry  an  air  cylinder  by  the  cylinder 

body.

•  Do  not  over-torque  air  cylinder  valves. 

ALWAYS  verify  that  the  hydrostatic  test 

facility  performing  your  cylinder  testing 

DOES NOT over-torque the cylinder valves 

when they reinstall them.

•  Some  CBRN  agents  may  not  present 

immediate  effects  from  exposure,  but  can 

result  in  delayed  impairment,  illness,  or 

death.

• Direct contact with CBRN agents requires 

proper handling of the SCBA after each use 

and  between  multiple  entries  during  the 

same use. 

• Decontamination and disposal procedures 

must  be  followed.  If  contaminated  with 

liquid  chemical  warfare  agents,  dispose  of 

the SCBA after decontamination.

•  The  respirator  should  not  be  used 

beyond  six  (6)  hours  after  initial  exposure 

to  chemical  warfare  agents  to  avoid  the 

possibility of agent permeation.

•  Prior  to  using  the  Titan  SCBA  for  the 

fi rst  time,  you  must  perform  fi t  testing  as 

described  in  section  VI.  Do  not  wear  this 

respirator if a satisfactory fi t, as determined 

by  the  fi t  testing  described  in  section  VI, 

cannot be obtained.

• You must read, understand, and follow all 

warnings,  instructions,  labels,  and  Safety 

Data  Sheets  (SDS),  etc.,  for  the  materials 

you  are  using  (e.g.,  paints, hardeners, 

insecticides, varnishes, etc.).

• You must also read, understand, and follow 

all warnings, instructions, etc., listed in the 

SDS  for  any  contaminants  that  may  be  or 

are present in the work area.

•  FAILURE  TO  COMPLY  WITH  THESE 

WARNINGS  MAY  RESULT  IN  PERSONAL 

INJURY, ILLNESS, OR DEATH.

WARNING

Detectable  amounts  of  chemicals  known 

to the State of California to cause cancer, 

birth  defects,  or  reproductive  harm  may 

be  found  in  this  product.  (This  warning 

required  by  California  Health  and  Safety 

Code Section 25249.6)

Part No.

Description

fACEPIECES

282053

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, SMALL BLACK NOSE CUP, SILICONE 

HEADSTRAP

282012

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, MEDIUM BLACK NOSE CUP, SILICONE 

HEADSTRAP

282013

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, LARGE BLACK NOSE CUP, SILICONE 

HEADSTRAP

282041

FACEPIECE—TWENTY/20+, CBRN, MEDIUM, 

BLACK, SMALL BLACK NOSE CUP, SILICONE 

HEADSTRAP

282022

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, MEDIUM BLACK NOSE CUP, SILICONE 

HEADSTRAP

282023

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, LARGE BLACK NOSE CUP, SILICONE 

HEADSTRAP

282043

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, SMALL BLACK NOSE CUP, SILICONE 

HEADSTRAP

282032

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, MEDIUM BLACK NOSE CUP, SILICONE 

HEADSTRAP

282033

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, LARGE BLACK NOSE CUP, SILICONE 

HEADSTRAP

282048

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, SMALL BLACK NOSE CUP, HEADNET

282016

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, MEDIUM BLACK NOSE CUP, HEADNET

282017

FACEPIECE—TWENTY/20+, CBRN, SMALL, 

BLACK, LARGE BLACK NOSE CUP, HEADNET

282050

FACEPIECE—TWENTY/20+, CBRN, MEDIUM, 

BLACK, SMALL BLACK NOSE CUP, HEADNET

282026

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, MEDIUM BLACK NOSE CUP, HEADNET

282027

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, LARGE BLACK NOSE CUP, HEADNET

282052

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, SMALL BLACK NOSE CUP, HEADNET

282036

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, MEDIUM BLACK NOSE CUP, HEADNET

282037

FACEPIECE—TWENTY/20+, CBRN, LARGE, 

BLACK, LARGE BLACK NOSE CUP, HEADNET

282053T

FACEPIECE—TWENTY/20+, CBRN, SMALL,  

BLACK, SMALL BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

282012T

FACEPIECE—TWENTY/20+, CBRN, SMALL,  

BLACK, MEDIUM BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

282013T

FACEPIECE—TWENTY/20+, CBRN, SMALL,  

BLACK, LRG BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

III. PARTS LIST

282041T

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, SMALL BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

282022T

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, MEDIUM BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

282023T

FACEPIECE—TWENTY/20+, CBRN, MEDIUM,  

BLACK, LARGE BLACK NOSE CUP, W/TEMPLE 

INSERTS, SILICONE HEADSTRAP

Содержание Titan SCBA

Страница 1: ...ator until you completely read and understand this instruction manual You are required to inspect your respirator prior to putting it into field service Please refer to the inspection procedures in this manual Failure to comply with this warning may lead to illness personal injury or death Honeywell International Inc 900 Douglas Pike Smithfield RI 02917 1 800 873 5242 HSPtechsupport Honeywell com w...

Страница 2: ...Honeywell Titan SCBA 20132 ...

Страница 3: ...ble Additional critical cautions and limitations apply Refer to EBSS in the user s instructions CAUTIONS AND LIMITATIONS S SPECIAL OR CRITICAL USER S INSTRUCTIONS 1 This respirator is approved for use above 25 F 31 7 C when using the 2820XX series facepiece 2 Use with adequate skin protection when worn in gases or vapors that poison by skin absorption for example hydrocy anic acid gas 3 Approved o...

Страница 4: ... the product must be used maintained and inspected as prescribed in the owner s instruction manual including prompt replacement or repair of defective parts mandatory flow tests and overhauls and such other necessary maintenance and repair as may be required Normal wear and tear parts damaged by abuse misuse negligence or accidents batteries and installed accesso ries which have separate warrantie...

Страница 5: ...nterface Considerations 18 VII CYLINDER FILLING SAFETY 18 A Inspection 19 B Filling Procedures 20 VIII MAINTENANCE 20 A Facepiece Cleaning 20 B Second Stage Regulator Cleaning 21 C Exterior Surfaces Cleaning 21 D Inspection see Inspection Table page 27 21 E Repair see Repair Table page 28 21 F Functional Testing see page 29 22 G Cylinder Recharging 22 H Cold Weather Operation and Maintenance 22 1 ...

Страница 6: ...iv Honeywell Titan SCBA 20132 This page intentionally left blank ...

Страница 7: ...al Your Honeywell respirator has been WARNING Continued constructed of materials selected after careful consideration for their performance safety and durability However all materials have exposure limitations to flame extremes of heat and cold or to the many chemicals in use today No materials exist that can be used safely in all of these environments This product contains chemicals known to the S...

Страница 8: ...epiece remains positive under most working conditions but as with all SCBAs negative pressure excursions are possible Conditions when an SCBA can experience WARNING Continued negative facepiece pressures include but are not limited to 1 the SCBA is improperly worn 2 the SCBA is not used in accordance with the instructions 3 the SCBA is improperly maintained or 4 the SCBA is subjected to over breat...

Страница 9: ... found in this product This warning required by California Health and Safety Code Section 25249 6 Part No Description fACEPIECES 282053 FACEPIECE TWENTY 20 CBRN SMALL BLACK SMALL BLACK NOSE CUP SILICONE HEADSTRAP 282012 FACEPIECE TWENTY 20 CBRN SMALL BLACK MEDIUM BLACK NOSE CUP SILICONE HEADSTRAP 282013 FACEPIECE TWENTY 20 CBRN SMALL BLACK LARGE BLACK NOSE CUP SILICONE HEADSTRAP 282041 FACEPIECE T...

Страница 10: ...1ST STAGE REGULATOR BELL ALARM 4500 PSIG 969180 2ND STAGE REGULATOR 930190 BACKPACK TITAN 930192 BACKPACK TITAN ESCAPE 930191 BACKPACK TITAN ALLIGATOR CLIPS Part No Description 930189 INTEGRATED BATTERY PACK TITAN 930186 BATTERY PACK HUD CONNECTOR 2216 PSIG 33 930188 BATTERY PACK HUD CONNECTOR 4500 PSIG 33 921342 INTERMEDIATE PRESSURE HOSE CABLE WITH ELECTRICAL PNEUMATIC COUPLING SAR 981013 INTERM...

Страница 11: ...4500 PSIG 30 MIN CARBON 962869 NECKSTRAP KIT TWENTY 20 FACEPIECE 975460 CHEST STRAP KIT 975465 D RING KIT 969019 HEADNET W SILICONE STRAP KIT 962150 FACEPIECE WITH TEMPLE INSERTS KIT SMALL BUTYL 962153 FACEPIECE WITH TEMPLE INSERTS KIT MEDIUM BUTYL 962154 FACEPIECE WITH TEMPLE INSERTS KIT LARGE BUTYL 975535 WAIST BELT EXTENDER 930176 INTEGRATED PASS 2216 PSIG GAUGE 33 WITHOUT PATHFINDER TITAN 9301...

Страница 12: ...Up Display HUD 2 The air cylinder is of composite construction with an aluminum inner liner overwrapped by carbon fiber and has a maximum working pressure of 4500 psig high pressure in 30 45 and 60 minute durations or 2216 psig low pressure in 30 minute duration An all aluminum cylinder and fiberglass composite hoop wrapped cylinder with a maximum working pressure of 2216 psig low pressure in 30 m...

Страница 13: ... the lower right of the backpack performs the same functions 3 The back PASS has an amber LED battery status indicator In storage or when the SCBA is activated manually or by pressure from the cylinder the amber LED flashes every ten seconds to indicate a low battery condition and will cease flashing altogether to indicate a dead battery An audible beep will also sound every ten seconds to indicat...

Страница 14: ...78906 RIT Kit provide a means for equalizing pressure in SCBA cylinders during a rescue An attendant rescue crew member must assist with the cylinder pressure equalization 2 The RIC UAC is located adjacent to the CGA hand wheel of the Titan SCBA on the lower left side of the backpack when looking at the cylinder with the valve pointing down The RIC UAC is accompanied by a relief valve located on t...

Страница 15: ...ation fasteners e Lift the SCBA from the case 2 Carton packaging a Remove the facepiece from the box if supplied b Remove the plastic transportation cradle from the box with the SCBA connected to it c Cut both locking straps securing the SCBA to the transportation cradle d Lift the SCBA from the cradle CAUTION Exercise extreme care when engraving identification markings on SCBA components Engraving...

Страница 16: ...net a Fully loosen the lower head straps b If the facepiece has a neck strap place the neck strap over your head c Place your chin in the chin cup pull the headnet over your head and tighten it by pulling evenly on the upper and lower straps See Figure 4 Make sure that your chin is properly recessed in the chin cup d Center the facepiece and flatten the headnet with a wiping motion toward the back...

Страница 17: ...BRN approval label and that the facepiece is a CBRN facepiece as described below The NIOSH CBRN approval label is located on the upper back section of the backpack frame on the pressure transducer cover If you cannot read the NIOSH CBRN approval label with the cylinder installed on the SCBA remove the cylinder from the backpack to verify the NIOSH CBRN approval label You MUST use a CBRN facepiece ...

Страница 18: ... cylinder valve gauge reads in the green FULL zone WARNING Check the cylinder latch each time the cylinder is installed Adjust the cylinder band to match the cylinder size and ensure that the cam over buckle is securely locked in place Failure to comply with this warning may lead to personal injury illness or death 4 Check the latch on the cylinder band and ensure that the cylinder is secure in th...

Страница 19: ...14 Figure 13 Loosen Headstraps Chin in Chin Cup vii Perform a leak check as described in section VI E page 14 NOTE When properly adjusted the headstrap hub should be centered on the back of your head and the lower straps should be below your ears Make sure that your chin is properly recessed in the chin cup b Optional Headnet WARNING Ensure that the three locking fabric straps located across the f...

Страница 20: ...play HUD to ensure that the display reads full cylinder pressure all four green LEDs lit vi Perform a leak check as described in section VI E page 14 NOTE When properly adjusted the headnet should be centered on the back of your head and the lower straps should be below your ears D Exhalation Valve Test WARNING Do not use this SCBA in a contaminated atmosphere if the exhalation valve is not workin...

Страница 21: ...e SCBA is being worn should only be done when the circum stances justify exposing the SCBA user to the added risk associated with the fill procedure First stage pressure reducers equipped with the RIC UAC have a pressure relief valve PRV incorporated into the first stage pressure reducer housing The WARNING The audible alarm must sound and the HUD LEDs must flash in sequence as the system is pressu...

Страница 22: ...V is designed to vent air to atmosphere when the fill pressure exceeds the service pressure of the cylinder The PRV will reset close at a pressure below the service pressure of the SCBA If a high pressure 4500 psig fill supply cylinder is used on a 2216 psig SCBA the PRV may open and vent air to atmosphere WARNING NEVER use the RIC UAC for routine filling of SCBA cylinders The RIC UAC is intended t...

Страница 23: ...t 1 Cylinder Removal a Close the cylinder valve and re engage the cylinder valve locking sleeve if so equipped b Press the override button or open the bypass valve on the second stage regulator to vent air from the SCBA WARNING Use extreme care when changing cylinders DO NOT allow moisture or ice to enter the regulator system Moisture or ice entering the regulator system may cause the SCBA to free...

Страница 24: ...ers used with this SCBA a When replacing a cylinder of the same diameter or smaller diameter i Flip the cam over buckle on the right side up and slide the cylinder in until the dome of the cylinder rests on the two protrusions of the bat tery cover ii With the cam over buckle on the right side fully flipped up adjust the tank band snug against the cylinder by squeezing the tank band so the teeth o...

Страница 25: ...ened or blistered paint charred decals melted or distored gauge lens etc 2 Composite Cylinders Ensure that no more than five years have elapsed since the last hydrostatic test has been performed on carbon cylinders and that the cylinder is less than 15 years old 30 years old for Extended Life cylinders Inspect the exterior of the cylinder for dents gouges or cuts which have penetrated and caused s...

Страница 26: ...r use Cylinders should not be stored partially charged for two reasons a If used without recharge the service duration of the apparatus is reduced b The safety relief device is designed specifically to protect a fully charged cylinder from the effects of a fire or from mechanical shock For maximum safety the cylinders should be stored fully charged If the cylinder is stored empty and the valve is ...

Страница 27: ...regulator to prevent water or contaminants from entering the regulator outlet 1 Make a cleaning solution of warm water and a mild detergent 2 Have a bucket of fresh water available for rinsing 3 Install the second stage cleaning cap P N 961170 4 With the regulator facing downward clean the exterior surfaces with a soft brush 5 With the regulator facing downward immediately rinse the exterior with ...

Страница 28: ...e during cold weather conditions to reduce ice forma tion on the facepiece lens in the AIR KLIC and in the exhalation valve Honeywell also recommends a full flow test be per formed per NFPA 1852 Standard on Selection Care and Maintenance of Open Circuit Self Contained Breathing Apparatus SCBA 2013 Edition or latest edition for additional inspection requirements for SCBAs used for firefighting E Re...

Страница 29: ...but ton returns j Should ice form on the regulator while the regulator is in the waist strap mounted regulator holder rotate the regulator to break off the ice then remove the regulator from the regulator holder b Prior to donning the facepiece in cold weather visually inspect the lens AIR KLIC and exhalation valve for ice c If ice is present warm the facepiece to melt the ice Ice may be melted by...

Страница 30: ...used during actual operations b During cold weather operations do not place cylin ders or SCBA components into wet or snowy areas k If the AIR KLIC buttons are frozen and the regulator cannot be removed from the regulator holder do not force the buttons Unbuckle the waist belt and place the belt regulator holder and regulator under outer wear next to your body to warm it until the AIR KLIC buttons...

Страница 31: ...ly loosen the facepiece headstraps f Place the facepiece in a mask bag 2 After inspection cleaning and necessary repair the SCBA should be stored away from dust sunlight heat extreme cold excessive moisture or damaging chemi cals J flow Test WARNING Direct contact with CBRN agents requires proper handling of the SCBA after each use and between multiple entries during the same use Decontamination a...

Страница 32: ... for 15 years and the first stage pressure reducer which is warranted for the life of the product During these periods Honeywell will repair or replace defective parts at Honey well s option Freight charges to and from the Honeywell factory shall be paid by the purchaser EXCLUSIONS NOTWITHSTANDING ANY CONTRARY TERM IN THE PURCHASER S PURCHASE ORDER OR OTHERWISE THE ONLY WARRANTY EXTENDED BY Honeyw...

Страница 33: ...bris in the outlet port screen and grill cracked 4 Hose or fittings corroded cracked or leaking 5 Sticking release and shutoff buttons 6 Loose regulator outlet GAUGE 1 Gauge lens scratched pointer deformed or stuck 2 Hose or fittings corroded cracked or leaking 3 Torn rubber boot HEADS UP DISPLAY HUD 1 Display cover scratched or damaged 2 Cable cracked or split 3 Dirty or damaged display including...

Страница 34: ...skirt away from the lens 4 Remove the nozzle cover by pressing the ratchet ring with a finger and unscrewing the AIR KLIC counterclockwise 5 Remove the nozzle by pushing it from the front of the facepiece Use thumbs to press the locking tabs at the sides of the nozzle DO NOT push on the spring retainer 6 Place the nozzle into the new lens 7 Reassemble the nozzle cover and AIR KLIC 8 Install the no...

Страница 35: ...5 Continue to open and close the bypass valve slowly until the HUD display reads 1 2 full 6 Verify that the 50 warning is working correctly the green LED representing 1 2 cylinder pressure should blink on and off for approximately 20 seconds then stay lighted continuously 7 Continue to open and close the bypass valve slowly until the HUD display reads 1 3 full The audible and visual alarm should b...

Страница 36: ...able Additional critical cautions and limitations apply Refer to EBSS in the user s instructions CAUTIONS AND LIMITATIONS S SPECIAL OR CRITICAL USER S INSTRUCTIONS 1 This respirator is approved for use above 25 F 31 7 C when using the 2820XX series facepiece 2 Use with adequate skin protection when worn in gases or vapors that poison by skin absorption for example hydrocy anic acid gas 3 Approved ...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...www Honeywellsafety com ...

Отзывы: