Honeywell Titan SCBA Скачать руководство пользователя страница 14

8

Honeywell Titan SCBA, 2013

2

WARNING —Continued

•  Turn  off  the  free  fl owing  regulator  by 

pressing  the  shutoff  button  on  the  second 

stage regulator cover.

•  Check  the  SCBA  pressure  gauge  to 

determine if it is necessary to replenish the 

SCBA air supply prior to continuing use.

•  Failure  to  comply  with  this  warning  may 

lead to personal injury, illness, or death.

The pressure demand second stage regulator is 

mounted on the facepiece by the Honeywell AIR 

KLIC™ system. The mechanism automatically locks in 

place when the regulator is pushed into the AIR KLIC, 

and is detached when both of the release buttons are 

pressed. To prevent inadvertent air fl ow, the regulator 

will not operate until the First-Breath-On mechanism is 

activated or the manual override button on the front of 

the regulator is pressed. The fl ow of air can be stopped 

by pressing the First-Breath-On shutoff button. The 

large red knob on the right side of the regulator controls 

an adjustable bypass valve. Turning this knob counter-

clockwise provides a constant fl ow of air.

f. facepiece

WARNING

You  MUST  use  a  CBRN  facepiece  (2820XX 

series) when using this SCBA in potential or 

known  CBRN  contaminated  atmospheres. 

Use  of  a  facepiece  other  than  a  CBRN 

facepiece will void NIOSH CBRN certifi cation 

and NFPA compliance certifi cation, and may 

lead to personal injury, illness, or death.

The Titan SCBA/SAR must be used with a Twenty/20+ 

facepiece (2820XX series), which features a special 

wide-lip sealing surface and fi ve-point silicone head-

strap harness or optional Headnet harness. The lens 

is treated with an abrasion-resistant coating on the 

outside surface of the lens, and a permanent anti-fog 

coating on the inside of the lens. The nozzle houses a 

removable nose cup, speaking diaphragm, and exhala-

tion valve. The AIR KLIC is threaded into the nozzle 

and secured by a ratchet mechanism to prevent leak-

age and provide a secure mount for the second stage 

regulator.

G. Rapid Intervention Crew/Company Universal Air 

Connection (RIC UAC)

NOTE

The  Titan  SCBA  comes  equipped  with  the 

Rapid  Intervention  Crew/Company  Universal 

Air Connection (RIC UAC). 

1. The RIC UAC and fi ll hose (purchased separately in 

the P/N 968970 or 978906 RIT Kit) provide a means for 

equalizing pressure in SCBA cylinders during a rescue. 

An attendant/rescue crew member must assist with the 

cylinder pressure equalization.

2. The RIC UAC is located adjacent to the CGA hand-

wheel of the Titan SCBA, on the lower left 

side of the 

backpack (when looking at the cylinder with the valve 

pointing down). The RIC UAC is accompanied by a 

relief valve located on the fi rst stage pressure reducer. 

The relief valve is designed to vent air to atmosphere 

when the fi ll pressure exceeds the cylinder service 

pressure, in order to prevent cylinder over-pressur-

ization. The RIC UAC has a dust plug which must be 

installed over the coupling at all times before and after 

fi lling operations. The RIC UAC fi ll hose has the mating 

fi ll coupling. A directional fl ow control piston is located 

in the quick-disconnect coupling to prevent air loss and 

hose whipping if the hose is installed incorrectly. The 

quick-disconnect coupling is supplied with dust plugs 

which must be installed when the fi ll hose is not in use.

WARNING

• The RIC UAC has a dust plug which must 

be  installed  over  the  coupling  at  all  times 

before and after fi lling operations.

•  DO  NOT  allow  oil,  grease,  or  other 

contaminants  to  come  in  contact  with  the 

quick-disconnect couplings. 

•  DO  NOT  use  air  other  than  breathing  air, 

Grade  D  or  better,  conforming  to  CGA 

G-7.1 Commodity Specifi cation for Air. The 

moisture  content,  expressed  as  dewpoint, 

shall  be  maintained  at  -65°F  (-53.9°C)  or 

lower,  or  less  than  24.0  ppm  by  volume 

moisture content.

• The Honeywell RIC UAC and RIC UAC fi ll 

hose must ONLY be used to fi ll compressed 

air  cylinders.  The  Honeywell  RIC  UAC  and 

RIC UAC fi ll hose must NEVER be used:

1. As a buddy breathing device.

2. For SCBA-to-SCBA fi lling.

3. To provide a continuous air supply.

•  Failure  to  comply  with  this  warning  may 

lead to personal injury, illness, or death.

V. UNPACKAGING

IMPORTANT—READ CAREfULLY

A. Warranty Card

1. Fill in the warranty registration card with the required 

information.
2. Mail back the completed warranty registration card 

immediately.

3. To comply with NIOSH, Honeywell is required to 

retain the completed warranty registration card.

4. Always refer to the equipment serial number if a 

claim is made.

B. Removing the SCBA from the Packaging

1. Carrying case (if supplied)

a. Remove the carrying case from the box.
b. Lift both locking tabs on the case and open it.

Содержание Titan SCBA

Страница 1: ...ator until you completely read and understand this instruction manual You are required to inspect your respirator prior to putting it into field service Please refer to the inspection procedures in this manual Failure to comply with this warning may lead to illness personal injury or death Honeywell International Inc 900 Douglas Pike Smithfield RI 02917 1 800 873 5242 HSPtechsupport Honeywell com w...

Страница 2: ...Honeywell Titan SCBA 20132 ...

Страница 3: ...ble Additional critical cautions and limitations apply Refer to EBSS in the user s instructions CAUTIONS AND LIMITATIONS S SPECIAL OR CRITICAL USER S INSTRUCTIONS 1 This respirator is approved for use above 25 F 31 7 C when using the 2820XX series facepiece 2 Use with adequate skin protection when worn in gases or vapors that poison by skin absorption for example hydrocy anic acid gas 3 Approved o...

Страница 4: ... the product must be used maintained and inspected as prescribed in the owner s instruction manual including prompt replacement or repair of defective parts mandatory flow tests and overhauls and such other necessary maintenance and repair as may be required Normal wear and tear parts damaged by abuse misuse negligence or accidents batteries and installed accesso ries which have separate warrantie...

Страница 5: ...nterface Considerations 18 VII CYLINDER FILLING SAFETY 18 A Inspection 19 B Filling Procedures 20 VIII MAINTENANCE 20 A Facepiece Cleaning 20 B Second Stage Regulator Cleaning 21 C Exterior Surfaces Cleaning 21 D Inspection see Inspection Table page 27 21 E Repair see Repair Table page 28 21 F Functional Testing see page 29 22 G Cylinder Recharging 22 H Cold Weather Operation and Maintenance 22 1 ...

Страница 6: ...iv Honeywell Titan SCBA 20132 This page intentionally left blank ...

Страница 7: ...al Your Honeywell respirator has been WARNING Continued constructed of materials selected after careful consideration for their performance safety and durability However all materials have exposure limitations to flame extremes of heat and cold or to the many chemicals in use today No materials exist that can be used safely in all of these environments This product contains chemicals known to the S...

Страница 8: ...epiece remains positive under most working conditions but as with all SCBAs negative pressure excursions are possible Conditions when an SCBA can experience WARNING Continued negative facepiece pressures include but are not limited to 1 the SCBA is improperly worn 2 the SCBA is not used in accordance with the instructions 3 the SCBA is improperly maintained or 4 the SCBA is subjected to over breat...

Страница 9: ... found in this product This warning required by California Health and Safety Code Section 25249 6 Part No Description fACEPIECES 282053 FACEPIECE TWENTY 20 CBRN SMALL BLACK SMALL BLACK NOSE CUP SILICONE HEADSTRAP 282012 FACEPIECE TWENTY 20 CBRN SMALL BLACK MEDIUM BLACK NOSE CUP SILICONE HEADSTRAP 282013 FACEPIECE TWENTY 20 CBRN SMALL BLACK LARGE BLACK NOSE CUP SILICONE HEADSTRAP 282041 FACEPIECE T...

Страница 10: ...1ST STAGE REGULATOR BELL ALARM 4500 PSIG 969180 2ND STAGE REGULATOR 930190 BACKPACK TITAN 930192 BACKPACK TITAN ESCAPE 930191 BACKPACK TITAN ALLIGATOR CLIPS Part No Description 930189 INTEGRATED BATTERY PACK TITAN 930186 BATTERY PACK HUD CONNECTOR 2216 PSIG 33 930188 BATTERY PACK HUD CONNECTOR 4500 PSIG 33 921342 INTERMEDIATE PRESSURE HOSE CABLE WITH ELECTRICAL PNEUMATIC COUPLING SAR 981013 INTERM...

Страница 11: ...4500 PSIG 30 MIN CARBON 962869 NECKSTRAP KIT TWENTY 20 FACEPIECE 975460 CHEST STRAP KIT 975465 D RING KIT 969019 HEADNET W SILICONE STRAP KIT 962150 FACEPIECE WITH TEMPLE INSERTS KIT SMALL BUTYL 962153 FACEPIECE WITH TEMPLE INSERTS KIT MEDIUM BUTYL 962154 FACEPIECE WITH TEMPLE INSERTS KIT LARGE BUTYL 975535 WAIST BELT EXTENDER 930176 INTEGRATED PASS 2216 PSIG GAUGE 33 WITHOUT PATHFINDER TITAN 9301...

Страница 12: ...Up Display HUD 2 The air cylinder is of composite construction with an aluminum inner liner overwrapped by carbon fiber and has a maximum working pressure of 4500 psig high pressure in 30 45 and 60 minute durations or 2216 psig low pressure in 30 minute duration An all aluminum cylinder and fiberglass composite hoop wrapped cylinder with a maximum working pressure of 2216 psig low pressure in 30 m...

Страница 13: ... the lower right of the backpack performs the same functions 3 The back PASS has an amber LED battery status indicator In storage or when the SCBA is activated manually or by pressure from the cylinder the amber LED flashes every ten seconds to indicate a low battery condition and will cease flashing altogether to indicate a dead battery An audible beep will also sound every ten seconds to indicat...

Страница 14: ...78906 RIT Kit provide a means for equalizing pressure in SCBA cylinders during a rescue An attendant rescue crew member must assist with the cylinder pressure equalization 2 The RIC UAC is located adjacent to the CGA hand wheel of the Titan SCBA on the lower left side of the backpack when looking at the cylinder with the valve pointing down The RIC UAC is accompanied by a relief valve located on t...

Страница 15: ...ation fasteners e Lift the SCBA from the case 2 Carton packaging a Remove the facepiece from the box if supplied b Remove the plastic transportation cradle from the box with the SCBA connected to it c Cut both locking straps securing the SCBA to the transportation cradle d Lift the SCBA from the cradle CAUTION Exercise extreme care when engraving identification markings on SCBA components Engraving...

Страница 16: ...net a Fully loosen the lower head straps b If the facepiece has a neck strap place the neck strap over your head c Place your chin in the chin cup pull the headnet over your head and tighten it by pulling evenly on the upper and lower straps See Figure 4 Make sure that your chin is properly recessed in the chin cup d Center the facepiece and flatten the headnet with a wiping motion toward the back...

Страница 17: ...BRN approval label and that the facepiece is a CBRN facepiece as described below The NIOSH CBRN approval label is located on the upper back section of the backpack frame on the pressure transducer cover If you cannot read the NIOSH CBRN approval label with the cylinder installed on the SCBA remove the cylinder from the backpack to verify the NIOSH CBRN approval label You MUST use a CBRN facepiece ...

Страница 18: ... cylinder valve gauge reads in the green FULL zone WARNING Check the cylinder latch each time the cylinder is installed Adjust the cylinder band to match the cylinder size and ensure that the cam over buckle is securely locked in place Failure to comply with this warning may lead to personal injury illness or death 4 Check the latch on the cylinder band and ensure that the cylinder is secure in th...

Страница 19: ...14 Figure 13 Loosen Headstraps Chin in Chin Cup vii Perform a leak check as described in section VI E page 14 NOTE When properly adjusted the headstrap hub should be centered on the back of your head and the lower straps should be below your ears Make sure that your chin is properly recessed in the chin cup b Optional Headnet WARNING Ensure that the three locking fabric straps located across the f...

Страница 20: ...play HUD to ensure that the display reads full cylinder pressure all four green LEDs lit vi Perform a leak check as described in section VI E page 14 NOTE When properly adjusted the headnet should be centered on the back of your head and the lower straps should be below your ears D Exhalation Valve Test WARNING Do not use this SCBA in a contaminated atmosphere if the exhalation valve is not workin...

Страница 21: ...e SCBA is being worn should only be done when the circum stances justify exposing the SCBA user to the added risk associated with the fill procedure First stage pressure reducers equipped with the RIC UAC have a pressure relief valve PRV incorporated into the first stage pressure reducer housing The WARNING The audible alarm must sound and the HUD LEDs must flash in sequence as the system is pressu...

Страница 22: ...V is designed to vent air to atmosphere when the fill pressure exceeds the service pressure of the cylinder The PRV will reset close at a pressure below the service pressure of the SCBA If a high pressure 4500 psig fill supply cylinder is used on a 2216 psig SCBA the PRV may open and vent air to atmosphere WARNING NEVER use the RIC UAC for routine filling of SCBA cylinders The RIC UAC is intended t...

Страница 23: ...t 1 Cylinder Removal a Close the cylinder valve and re engage the cylinder valve locking sleeve if so equipped b Press the override button or open the bypass valve on the second stage regulator to vent air from the SCBA WARNING Use extreme care when changing cylinders DO NOT allow moisture or ice to enter the regulator system Moisture or ice entering the regulator system may cause the SCBA to free...

Страница 24: ...ers used with this SCBA a When replacing a cylinder of the same diameter or smaller diameter i Flip the cam over buckle on the right side up and slide the cylinder in until the dome of the cylinder rests on the two protrusions of the bat tery cover ii With the cam over buckle on the right side fully flipped up adjust the tank band snug against the cylinder by squeezing the tank band so the teeth o...

Страница 25: ...ened or blistered paint charred decals melted or distored gauge lens etc 2 Composite Cylinders Ensure that no more than five years have elapsed since the last hydrostatic test has been performed on carbon cylinders and that the cylinder is less than 15 years old 30 years old for Extended Life cylinders Inspect the exterior of the cylinder for dents gouges or cuts which have penetrated and caused s...

Страница 26: ...r use Cylinders should not be stored partially charged for two reasons a If used without recharge the service duration of the apparatus is reduced b The safety relief device is designed specifically to protect a fully charged cylinder from the effects of a fire or from mechanical shock For maximum safety the cylinders should be stored fully charged If the cylinder is stored empty and the valve is ...

Страница 27: ...regulator to prevent water or contaminants from entering the regulator outlet 1 Make a cleaning solution of warm water and a mild detergent 2 Have a bucket of fresh water available for rinsing 3 Install the second stage cleaning cap P N 961170 4 With the regulator facing downward clean the exterior surfaces with a soft brush 5 With the regulator facing downward immediately rinse the exterior with ...

Страница 28: ...e during cold weather conditions to reduce ice forma tion on the facepiece lens in the AIR KLIC and in the exhalation valve Honeywell also recommends a full flow test be per formed per NFPA 1852 Standard on Selection Care and Maintenance of Open Circuit Self Contained Breathing Apparatus SCBA 2013 Edition or latest edition for additional inspection requirements for SCBAs used for firefighting E Re...

Страница 29: ...but ton returns j Should ice form on the regulator while the regulator is in the waist strap mounted regulator holder rotate the regulator to break off the ice then remove the regulator from the regulator holder b Prior to donning the facepiece in cold weather visually inspect the lens AIR KLIC and exhalation valve for ice c If ice is present warm the facepiece to melt the ice Ice may be melted by...

Страница 30: ...used during actual operations b During cold weather operations do not place cylin ders or SCBA components into wet or snowy areas k If the AIR KLIC buttons are frozen and the regulator cannot be removed from the regulator holder do not force the buttons Unbuckle the waist belt and place the belt regulator holder and regulator under outer wear next to your body to warm it until the AIR KLIC buttons...

Страница 31: ...ly loosen the facepiece headstraps f Place the facepiece in a mask bag 2 After inspection cleaning and necessary repair the SCBA should be stored away from dust sunlight heat extreme cold excessive moisture or damaging chemi cals J flow Test WARNING Direct contact with CBRN agents requires proper handling of the SCBA after each use and between multiple entries during the same use Decontamination a...

Страница 32: ... for 15 years and the first stage pressure reducer which is warranted for the life of the product During these periods Honeywell will repair or replace defective parts at Honey well s option Freight charges to and from the Honeywell factory shall be paid by the purchaser EXCLUSIONS NOTWITHSTANDING ANY CONTRARY TERM IN THE PURCHASER S PURCHASE ORDER OR OTHERWISE THE ONLY WARRANTY EXTENDED BY Honeyw...

Страница 33: ...bris in the outlet port screen and grill cracked 4 Hose or fittings corroded cracked or leaking 5 Sticking release and shutoff buttons 6 Loose regulator outlet GAUGE 1 Gauge lens scratched pointer deformed or stuck 2 Hose or fittings corroded cracked or leaking 3 Torn rubber boot HEADS UP DISPLAY HUD 1 Display cover scratched or damaged 2 Cable cracked or split 3 Dirty or damaged display including...

Страница 34: ...skirt away from the lens 4 Remove the nozzle cover by pressing the ratchet ring with a finger and unscrewing the AIR KLIC counterclockwise 5 Remove the nozzle by pushing it from the front of the facepiece Use thumbs to press the locking tabs at the sides of the nozzle DO NOT push on the spring retainer 6 Place the nozzle into the new lens 7 Reassemble the nozzle cover and AIR KLIC 8 Install the no...

Страница 35: ...5 Continue to open and close the bypass valve slowly until the HUD display reads 1 2 full 6 Verify that the 50 warning is working correctly the green LED representing 1 2 cylinder pressure should blink on and off for approximately 20 seconds then stay lighted continuously 7 Continue to open and close the bypass valve slowly until the HUD display reads 1 3 full The audible and visual alarm should b...

Страница 36: ...able Additional critical cautions and limitations apply Refer to EBSS in the user s instructions CAUTIONS AND LIMITATIONS S SPECIAL OR CRITICAL USER S INSTRUCTIONS 1 This respirator is approved for use above 25 F 31 7 C when using the 2820XX series facepiece 2 Use with adequate skin protection when worn in gases or vapors that poison by skin absorption for example hydrocy anic acid gas 3 Approved ...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...www Honeywellsafety com ...

Отзывы: