238
Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide
Power Configuration Mode
Start > Settings > Control Panel > Power Configuration Mode
There are three user selectable power configuration modes for the Thor VM2 available.
Additionally a UPS power configuration mode is supported and automatically selected
regardless of the user selected mode any time external power is not present.
control panel timeout values vary by the power configuration mode selected.
AC/DC Mode
This is the default power mode. In AC/DC mode the Thor VM2 is turned On when power
is connected. Ignition input is ignored when AC/DC Mode is enabled.
Note:
When the UPS battery has been depleted or disconnected (the Thor VM2 is first powered
out of the box, the front panel has been replaced, etc.) power the Thor VM2 manually by
pressing the power button. After the initial power up, the Thor VM2 powers on
automatically when power is attached and AC/DC mode is selected.
Thor VM2 is Off
Conditions
The Thor VM2 is Off and gets external power, such as
•
Thor VM2 is installed on a powered dock with the dock power switch On
•
Thor VM2 is already mounted to a dock and external power is applied to the dock
•
Thor VM2 is already mounted to a dock and the dock power switch is turned On
Result
The Thor VM2 boots. Once booted the Thor VM2 follows the AC/DC power scheme with
timers reset after the boot completes.
Thor VM2 is On
Conditions
The Thor VM2 is On and gets external power, such as
•
Thor VM2 is installed on a powered dock with the dock power switch On
•
Thor VM2 is already mounted to a dock and external power is applied to the dock
•
Thor VM2 is already mounted to a dock and the dock power switch is turned On
Содержание Thor VM2
Страница 1: ...User Guide Thor VM2 Vehicle Mounted Computer with Microsoft Windows Embedded CE 6 0 ...
Страница 16: ...4 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 63: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 51 ...
Страница 64: ...52 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 288: ...276 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 310: ...298 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 352: ...340 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 385: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 373 Hat Encoding ...
Страница 398: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VM2 CE UG Rev D 9 17 ...