is specified in the technical data, see page
▷
The curly brackets mean “numerical value of”.
▷
For detailed information on the check test op-
erating sequence, see page 9 (Check test).
UMI peripherals
▷
The status
of the available interfaces for optional
communication modules is displayed.
Meter information
▷
Meter-specific technical data are displayed in
sub-menus by pressing the selection key and
the user keys , .
ON
OFF
Meter information
Identification &
calibration info
Meter information
Version :x.xx.xx
CRC :0x0000
Details
:REL YYMMDD
Year of man. :YYYY
Calibration information
Q1: 0.000m
3
/h CF1:16384
Q2: 6.000m
3
/h CF2:16384
Q3: 12.000m
3
/h CF3:16384
Properties
Volume :2.0dm
3
(S)
Qt :0.60dm
3
/h
DVGW Nr :NG-4701BM0442
Environmental contitions
Electromagnetic :E2
Mechanical :M1
Meter information:
–
Software version
–
CRC: software checksum
–
Software details
–
Year of manufacture
▷
Other screen descriptions (not illustrated):
Calibration information:
– Meter calibration parameters Q1 to Q3 (adjust-
ment values Q1 to Q3 for three-point calibration)
Meter characteristics:
–
Cyclic meter volume
–
Transitional flow rate Q
t
–
EN 1359 Reg. No.: NG-4701BM0443 (example)
Ambient conditions:
– Electromagnetic
– Mechanical
Establishing an optical
communications link
▷
Depending on customer requirements, the opti-
cal interface can be locked.
▷
In order to configure the electronic index for the
respective application, the optical communica-
tions link must be activated.
Position the opto-adapter head on the interface
provided.
12345
678
Press any user key.
▷
Optical communication is enabled for 1 minute.
▷
If the optical communications link is not used
during this time, the interface will be deactivated.
Initiate communication.
▷
The procedure depends on your user software.
▷
For further information, refer to the operating
instructions for communication modules type
ECM (for electronic index).
Changing the battery
WARNING
Risk of explosion in explosion-hazard areas!
– As a general rule, maintenance and repair work
should be avoided in explosive atmospheres.
– Check that the electrical system complies with
the special electrical explosion protection re-
quirements.
– When working on electrical equipment in an
explosion-hazard area, only design-approved
electrical operating equipment may be used.
– Use original spare parts supplied by Elster
GmbH, see page 14 (Spare parts).
▷
The battery is available as a spare part.
Prepare the index for changing the battery.
▷
The battery can only be replaced when the optical
communications link has been established, see
page 7 (Establishing an optical communica-
tions link). Otherwise, data can be lost.
Start the battery change procedure.
▷
The procedure depends on your user software.
▷
Important! The battery may only be removed
once a release message has been issued by
the index. Otherwise, an integrated valve will be
closed and/or an error message will be trans-
ferred via the communication module.
▷
The index confirms disconnection of the battery
with a sound sequence.
Replace the battery as quickly as possible.
002545
Q m
Q m
00254563
2734
Q max
Q min
M07 010
2
▷
The index confirms connection of the battery
with a sound sequence.
▷
The main screen appears when any key is
pressed.
▷
Optical communication is enabled for 1 minute.
If the optical communications link is not used
during this time, the interface will be deactivated.