background image

15

16

14

13

11

12

10

9

NOTE:

 If the indoor or remote temperature goes above or 

below operating range stated in specifications, the main 

unit’s display will show dashes “        ”

AUTO-SCANNING

Press and hold the 

CHANNEL 

button on the back on the 

main unit for 2 seconds – the icon “      ” will appear on the 

display’s middle line below the remote temperature channel 

number. All 3 remote temperatures will be displayed 

one-by-one automatically for 4 seconds each in the 

following sequence: Channel 1, Channel 2 and Channel 3.

To exit from scanning mode, press and hold the 

CHANNEL 

button (on the back) for 2 seconds, and the icon “      ” will 

disappear, returning the main unit to the default display mode.

CHECKING REMOTE RAINFALL DATA

The remote rainfall information line is located on the top 

line of the main unit’s display.

The rain icon “      ”  is located to the left of the rainfall reading 

and indicates the reception status from the remote rain gauge.

There are three types of reception status that may be 

displayed:

Press and hold the 

MODE 

button on the front panel to 

display the rainfall reading in inches or mm.

REMOTE SENSOR

FEATURES

• Remote temperature transmission to the main unit via 

433 MHz signal

• 30 metres transmission range without interference

• LCD display of measured temperature

•  Three transmission (3) channels selection

• Selection of the temperature display in Celsius or Fahrenheit

• Case can be wall mounted using built-in hanger

REMOTE RAIN GAUGE

D. Funnel-shaped top with battery compartment

  Contains battery compartment and rainfall counting 

electronics

 E. Battery compartment

  Holds two AA-size batteries

 F. Screws

  Secure battery compartment cover

 G.Built-in leveler

  Allows leveling rain gauge on the surface

 H.Bucket see-saw mechanism

  Collects the rainfall in one of its containers and 

self-empties once full

 I. Protective screen

  Protects the rain gauge funnel from debris

BATTERY INSTALLATION

REMOTE RAIN GAUGE

• Unlock the funnel-shaped top on the rain gauge by 

turning both knobs on the sides in an anti-clockwise 

direction.

• Remove the funnel-shaped top lifting it off the rain 

gauge bucket.

• Remove 7 small screws from the battery compartment 

cover using a small Phillips screwdriver.

• Insert 2 “AA” size alkaline batteries (not included), 

matching the polarities as shown in the battery 

compartment.

• Replace the battery compartment door and secure the 

screws.

• Insert the funnel-shaped top into the rain gauge bucket 

and secure it into place by turning the knobs clockwise.

RAIN GAUGE PLACEMENT TIPS

• Make sure that the remote rain gauge is level – check if 

the ball bearing inside the bucket is at the midpoint of 

the leveler.

• Place the protective screen over the top to protect the 

rain gauge from debris.

• Mount the rain gauge using mounting hardware provided.

• Make sure that the rain gauge is in open area where 

precipitation falls directly into the gauge’s bucket, 

ideally 600mm - 900mm above the ground.

BEFORE YOU BEGIN

• We recommend using alkaline batteries for the remote 

rain gauge, temperature sensor and main unit when 

temperatures are above 0

°

C (32

°

F). We recommend 

using lithium batteries for the temperature sensor when 

temperatures are below 0

°

C (32

°

F).

• Avoid using rechargeable batteries. (Rechargeable 

batteries cannot maintain correct power requirements).

ALWAYS

 install batteries in 

the remote rain gauge and 

the remote temperature sensor before

 the main unit.

• Insert batteries before first use, matching the polarity in

 the battery compartment

• Press 

RESET 

in the remote temperature sensor after 

each battery change with a paper clip or similar tool.

• Remove protective plastic screen from LCD display (If 

any)

• During an initial setup, place the main unit close to the 

remote rain gauge and remote temperature sensor

Important:

 Only after reception is established (the 

remote rainfall data and temperature will appear on the 

main unit’s display), you may position and mount the 

remote sensors (the rain gauge and the temperature 

sensor) and the main unit within the effective 

transmission range of 30 metres.

• The remote rain gauge must be placed outdoors on the 

open area, away from the walls, fences and trees and level.

• It is important that excess precipitation can freely flow 

from the remote rain gauge.

• The remote temperature sensor can be placed 

indoors or 

outdoors, depending on the area where the 

temperature is intended to be measured

. If you intend 

measuring outdoor temperature, place the remote 

temperature sensor outdoors.

A.

LED INDICATOR

• Flashes once when the remote temperature sensor 

transmits a reading to the main unit.

• Flashes twice when battery power is low.

B.

BATTERY COMPARTMENT

• Holds two AA-size batteries

C.

RESET

• Resets all readings

D.

CHANNEL SELECTOR

• Selects the desired channel

E.

WALL-MOUNT RECESSED OPENING

• Keeps the remote temperature sensor on the wall

F.

°

C/ 

°

F SWITCH

• Selects the temperature display in Celsius or Fahrenheit

•The main unit must be placed indoors.

NOTE:

1. Avoid pressing any buttons on the main unit 

before the 

remote rainfall and temperature data are displayed.

2. The effective operating range may be influenced by the 

surrounding building materials and how the receiver 

(main unit) and transmitters (remote rain gauge and 

temperature sensor) are positioned.

3. Place the remote rain gauge and temperature sensor so 

that it faces the main unit (receiver), minimizing 

obstructions such as doors, walls, and furniture.

4. Though the remote temperature sensors are 

weather-resistant, they should be placed away from 

direct sunlight, rain or snow. The best suggested 

location for the remote temperature sensor for outdoors 

is under the eave on the north side of the building.

NOTE:

 When the temperature falls below freezing, the 

batteries in the remote rain gauge and outdoor remote 

temperature sensor may have reduced voltage supply and 

a shorter effective range. We recommend using lithium 

batteries at temperatures of 0

°

C (32

°

F) and below.

Temperature readings are 

securely registered

No signals.

The Unit is in searching mode

˚

C

Rainfall readings are 

securely registered

No signals detected

- - -

The unit is in searching mode

THERMO – SENSOR

4 3 3 M H z   W I R E L E S S

3

RESET

˚C/˚F

CHANNEL

  1 2 3

E

F

B

A

D

C

REMOTE TEMPERATURE SENSOR

NOTE: Install the batteries; select the channel and 

temperature in C

°

 or F

°

 before mounting the remote 

temperature sensor.

• Remove the screws from the battery compartment with 

a small Phillips screwdriver.

• Set the channel. The switch is located in the battery 

compartment. Channel 1 is typically selected if only one 

remote sensor is being used.

• Install 2 “AA” size alkaline batteries (not included) 

matching the polarities shown in the battery compartment.

• Replace the battery compartment door and secure the 

screws.

• Secure remote temperature sensor in the desired location.

MAIN UNIT

• Open the battery compartment door.

• Install 2 batteries (UM-3 or “AA” size 1.5V) matching 

the polarity as shown in the battery compartment.

• Replace the battery compartment door.

LOW BATTERY WARNING

A low-battery indicator [      ] will appear on the remote 

rainfall reading line and the indoor or remote temperature 

reading line of the main unit, warning that the corresponding 

batteries need replacement.

HOW TO USE THE TABLE STAND

The main unit has a removable table stand that supports it 

on a flat surface.

Attach table stand to the bottom of the main unit in the slots 

provided.

The main unit can also be mounted on the wall using the 

recessed screw hole. The table stand must be removed prior 

to mounting. The remote temperature sensor can be similarly 

mounted or placed on a flat surface.

GETTING STARTED

After batteries are installed; remote temperature sensor will 

transmit temperature readings at about 45 second intervals. 

The remote rain gauge will transmit rainfall data at about 

183 second intervals. The main unit may take up to two 

minutes to receive the initial readings. Upon successful 

reception, the rainfall reading (

0.00

) will appear on the top 

line of the main unit’s display and the remote temperature 

will appear on the line below. The main unit will automatically 

update readings at 45-second intervals.

If no signals received from the remote temperature sensor 

within two minutes, dashes [

        

] will be displayed.

Press and hold the front panel 

DOWN 

(     ) button on the 

main unit for two seconds or until Rain symbol will start 

flashing, to initiate a signal search for the remote rainfall.

Press and hold the back panel 

DOWN 

(     ) button on the 

main unit for two seconds to initiate a signal search for the 

remote temperature.

REMOTE AND INDOOR TEMPERATURES

The remote temperature information is located on the 

middle line of the main unit’s display. The indoor temperature 

with the icon 

IN

 is located next to the remote temperature.

The wave icon above the remote channel number indicates 

the reception status from the remote temperature sensor.

There are three types of reception status that may be 

displayed:

SIZ

E A

A/U

M

3

SIZ

E A

A/U

M

3

D

G

E

I

H

F

Содержание TE150

Страница 1: ...his device monitors and displays rainfall data along with the indoor outdoor temperature from up to three remote locations In this package you will find One main unit receiver Please keep this manual handy as you use your new item It contains practical step by step instructions as well as technical specifications and precautions you should know One remote temperature sensor transmitter TS13C One r...

Страница 2: ... you intend measuring outdoor temperature place the remote temperature sensor outdoors A LED INDICATOR Flashes once when the remote temperature sensor transmits a reading to the main unit Flashes twice when battery power is low B BATTERY COMPARTMENT Holds two AA size batteries C RESET Resets all readings D CHANNEL SELECTOR Selects the desired channel E WALL MOUNT RECESSED OPENING Keeps the remote ...

Страница 3: ...ions Do not immerse the units in water Do not clean the units with abrasive or corrosive materials They may scratch the plastic parts and corrode the electronic circuits Do not subject the product to excessive force shock dust temperature or humidity which may result in malfunctions shorter lifespan damaged batteries and damaged parts Do not tamper with the units internal components Doing so will ...

Страница 4: ...is product is warranted from manufacturing defects for one year from date of retail purchase It does not cover damages or wear resulting from accident misuse abuse commercial use or unauthorized adjustment and repair Should you require assistance with this product and its operation please contact our Customer Service Hotline 1800 653 238 Please direct all returns to the place of the original purch...

Отзывы: