THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:

RESPIRATOR COMPONENTS

TC-

Protection

1

Alternate Respirators

Cautions and 

Limitations

2

.

N1125 S

N1125 M

/L

N1125 X

L

N1125-

O

V S

N1125-

O

V M

/L

N1125-

O

V X

L

N1125-

AG

 S

N1125-

AG

 M

/L

N1125-

AG

 X

L

N1115S

N1115M

/L

N1115X

L

N1105S

N1105M

/L

N1105X

L

N1139 S

N1139 M

/L

N1139 X

L

P1135M

/L

P1135X

L

P1135-

1.

 M

/L

P1135-

1.

 X

L

P1130 S

P1130 M

/L

P1130 X

L

84A-6750

N95

X

X

X

X

X

X

X

X

X

84A-6749

N95

X

X

X

84A-6748

N95

X

X

X

ABCJMNOP

84A-6751

N99

X

X

X

ABCJMNOP

84A-6752

P95

X

X

X

X

ABCJMNOP

84A-6767

P100

X

X

X

ABCJMNOP

1. Protection:

N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time 

use restrictions may apply

N99 - Particulate Filter (99% filter efficiency level) effective against particulate 

aerosols free of oil; time use restrictions may apply

.

2. Cautions and Limitations:
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. 
N - Never substitute, modify, add, or omit parts.  Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.

1-800-873-5242

HONEYWELL INTERNATIONAL INC.

P100- Particulate Filter (99.97% filter efficiency level) effective against all 

particulate aerosols.

P95-Particulate Filter (95% filter efficiency level) effective against all particulate aerosols

ABCJMNOP

ABCJMNOP

Содержание TC-84A-6750

Страница 1: ...tion it below your ears 4 Pull the top strap over your head and position it high on the back of your head 5 Respirators with adjustable head straps only adjust tension by pulling head straps evenly with both hands If tightened too much tension may be decreased by pushing out on the back of the buckle 6 Mold the nose area to the shape of the face running the fingertips of both hands from the top of...

Страница 2: ...asting operations or for fire fighting h In confined spaces such as tanks small rooms tunnels or vessels unless the confined space is well ventilated and the concentration of toxic contaminants is known to be and will continue to be below the Maximum Use Concentration recommended for this respirator i When conditions prevent a good face piece to face seal For example i the growth of beards mustach...

Страница 3: ...st which protection is required or a failure to follow either these Warnings and the Instructions for Use or the Cautions and Limitations contained within the NIOSH Approval Label on the other panel of this box will result in exposure to the hazardous materials and the risk of serious injury illness or death 5 All approved respirators shall be selected fitted used and maintained in accordance with...

Страница 4: ...use restrictions may apply 2 Cautions and Limitations A Not for use in atmospheres containing less than 19 5 percent oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected...

Отзывы: