Honeywell T8631A Скачать руководство пользователя страница 7

Third

System Switch

Digit

Position

0

OFF

1

COOL

2

HEAT

4

EM.HT.

c

If the system switch is in HEAT, the following se-
quence will occur:

Fourth Digit:  Not used.

CAUTION

Do NOT operate heating until heat pump warmup
procedure is followed. Refer to manufacturer’s
recommendations.

T8631A:

First press—1st stage heating and SYSTEM LED on.
Second press—heating and SYSTEM LED off.

T8631R:

First press—1st stage heating and SYSTEM LED on.
Second press—2nd stage heating also on.
Third press—2nd stage heating off.
Fourth press—1st stage heating and SYSTEM LED off.
(If system switch is in EM. HT., operation is as above,
except 1st stage heating is locked out.)

REFER TO OWNER’S MANUAL FOR PROGRAM-
MING INSTRUCTIONS AND HOMEOWNER
TROUBLESHOOTING.

7

69-0689—2

!

This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations, CRC c. 1374.

CAUTION

Do NOT operate cooling if outdoor temperature
is below 50

°

 F [10

°

 C]. Refer to manufacturer’s

recommendations.

First press—cooling system and SYSTEM LED on.
Second press—cooling system and SYSTEM LED off.

b

A four-digit code number will appear when the key is
released. The four digits of the code represent the
following options:

First

T8631A

T8631R

Digit

CPH

CPH

0

1

3

2

3

3

4

9

6

6

6

6

Second

Recovery

Digit

Model

Degrees

Type

0

T8631R

F

A.I.R.

a

1

T8631R

C

A.I.R.

a

2

T8631A

F

Conventional

3

T8631A

C

Conventional

4

T8631R

F

A.I.R.

a

5

T8631R

C

A.I.R.

a

6

T8631A

F

A.I.R.

a

7

T8631A

C

A.I.R.

a

!

a

Adaptive Intelligent Recovery™

Содержание T8631A

Страница 1: ...tion is complete check out product operation as provided in these instructions 5 Allow thermostat to warm to room temperature before operating IMPORTANT Afterwiringiscomplete pushexcesswire back into the hole and plug hole with nonhardening caulk putty or insulation to prevent drafts from affecting thermostat operation LOCATION Install thermostat and subbase about 5 ft 1 5 m above the floor in an ...

Страница 2: ...es Fig 1 Removing thermostat from subbase AUX HEAT HEAT AUTO COOL OFF ON AUTO FAN M3060 SYSTEM Fig 2 Mounting subbase on wall WIRES THROUGH WALL OPENING WALL WALL ANCHORS 2 SUBBASE MOUNTING HOLES MOUNTING SCREWS 2 M3061 HBUS SWITCH FAN OPERATIONAL SWITCH FOR T8631A ONLY 1 2 1 2 SWITCH UP DISCONNECTS THE HBUS FAN CAN BE SET FOR ELECTRIC HEAT OR CONVENTIONAL Fig 3 T8631A 1 stage heat 1 stage cool th...

Страница 3: ...RELAY EMERGENCY HEAT RELAY STAGE 1 HEAT RELAY COMPRESSOR CONTACTOR E HIGH LIMIT L E HEAT HIGH LIMIT TRANSFORMER E HEAT RED AUX HEAT GREEN HEAT 2 M3065A POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED REMOVE JUMPER IF PRESENT FOR SYSTEM WITH ISOLATED STAGE 1 HEATING AND COOLING CONNECTIONS DENOTES THERMOSTAT TO SUBBASE INTERCONNECT DO NOT CONNECT H BUS WIRES TO THERMOSTAT ...

Страница 4: ...naces it can be necessary to change the cycle rate to the hot water setting Cooling cycle rate is not adjustable but heating can be adjusted by turning one or both 1A and 1B screws on the back of the thermostat See Fig 8 for adjustments The screw should only be backed out about one half turn or be turned in until tight ADAPTIVE INTELLIGENT RECOVERY CON VENTIONAL RECOVERY CONVERSION The T8631A and ...

Страница 5: ...check to see that system power is on check to see that voltage between R and C is 20 to 30 Vac Fig 10 Mounting the thermostat on subbase M3059 PM RETURN MON HEAT ON SYSTEM AUTO PM RETURN MON HEAT ON SYSTEM RUN PROGRAM TIME TEMPERATURE PRESENT SETTING SKIP NEXT PERIOD CHANGE TO LAST PERIOD SET PRESENT DAY TIME HOLD TEMP DAY SET HEAT COOL SLEEP LEAVE AHEAD WARMER RETURN BACK COOLER WAKE A B C HEAT A...

Страница 6: ... AHEAD and BACK keys at the same time While holding keys down all segments of the display should be on See Fig 11 2 SetsystemswitchtoOFF PressAHEADandBACK and PRESENT SETTING keys at the same time to enter self test 3 Press each key as listed below and look for re sponses listed as key is held down and released Look For This Response Press This Key Key Down Key Released PRESENT SETTING 15 see note...

Страница 7: ...O OWNER S MANUAL FOR PROGRAM MING INSTRUCTIONS AND HOMEOWNER TROUBLESHOOTING 7 69 0689 2 This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations CRC c 1374 CAUTION Do NOT operate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s recommendations First press cooling system and SYSTEM LED on Second press cooling system and SYST...

Страница 8: ...ding Control Home and Building Control Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley Minnesota 55422 Scarborough Ontario M1P 2V9 Printed in Taiwan R O C ...

Отзывы: