6

69-0819

Programming Your Thermostat

The thermostat can be programmed in your hand

before it is installed or after it is on the wall if you make
sure the batteries are installed. If you need to install or
replace the batteries, refer to the Maintaining Your
Thermostat section.

Your thermostat can be programmed for seven days

(separate programs for each day of the week).

PROGRAMMING

The personal programming chart can be helpful for

plannng your program schedule of time and temperature
settings for various times of the day.

Four time periods are available:

MORNING is the time period when you want the zone

at a comfortable temperature to begin the day. (This
will be a higher temperature during the heating
season, or a lower temperature during the cooling
season.) This is the only period that must contain a
time and temperature for every day.

MIDDAY is the time period you can set for an energy-

saving temperature while the zone is unoccupied.
(This will be a lower temperature during the heating
season, or a higher temperature during the cooling
season.)

EVENING is the time period when you want the zone

at a comfortable temperature for family activities in
the evening.

NIGHT is the time period you can set for an energy-

saving temperature while you are sleeping or the
zone is unoccupied. Set it to start at your family’s
normal bedtime. (For more comfortable sleeping in
the cooling season, some people choose not to
raise the cooling temperature during the night.)

You can set a different schedule for each day of the

week because your requirements will probably be
different for each day.

Fill in the times and temperatures you desire for each

day of the week. If you decide not to program the

Содержание T8611M7065

Страница 1: ...1 69 0819 J H 5 94 Form Number 69 0819 Microelectronic Programmable Thermostat Owner s Manual ...

Страница 2: ...itch 13 Operating Your Thermostat 14 Temporarily Changing the Program 14 Permanently Changing the Program 15 Manually Operating the Thermostat 15 Canceling Program Settings 15 Checking the Program Times and Temperatures 16 Checking the Current Temperature Settings 16 Maintaining Your Thermostat 17 Removing the Thermostat 17 Replacing the Thermostat 18 Replacing the Batteries 19 Power Outages 19 Gl...

Страница 3: ...ndard thermostats sense only air temperature which may or may not reflect how hot or cold the zone actually feels to a human being Your new thermostat reads the temperature of the wall as well as the air and responds to temperature changes as little as one degree Fahrenheit so zone temperature is more likely to feel right to you and your family THE OPTIMUM COMFORT AND ENERGY SAVINGS SOLUTION This ...

Страница 4: ...rt time accordingly It typically takes four to eight days after installation for this thermostat to adjust to the weather your life style home construction and heating cooling system The thermostat calculates the LEAVE RETURN recovery separately from the SLEEP WAKE recovery IMPORTANT With Programmed Recovery program the times when you want your home comfortable The thermostat will decide how early...

Страница 5: ...ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED SET PT AM PM SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED SET PT System Operating in Energy Savings Mode Recovery Begins Recovery Continues System Operating in Comfort Mode ENERGY SAVINGS PERIOD RECOVERY FROM ENERGY SAVINGS COMFORT PERIOD TIME TEMPERATURE THE THERMOSTAT USES THE SAME SCHEME TO RETURN GRAD...

Страница 6: ...the cooling season This is the only period that must contain a time and temperature for every day MIDDAY is the time period you can set for an energy saving temperature while the zone is unoccupied This will be a lower temperature during the heating season or a higher temperature during the cooling season EVENING is the time period when you want the zone at a comfortable temperature for family act...

Страница 7: ...e does not require it For example a zone that is occupied Monday and Tuesday only requires programs for MORNING and NIGHT IMPORTANT Always press the keys with your finger or similar blunt tool Use of sharp instruments like a pen or pencil point can damage the keyboard If you make an error at any time during programming just press the RUN PROGRAM key and continue at the step where you left off PROG...

Страница 8: ...8 69 0819 Monday Start Time Heating Temp 1 Cooling Temp 1 MORNING MIDDAY EVENING NIGHT Tuesday MORNING MIDDAY EVENING NIGHT Wednesday MORNING MIDDAY EVENING NIGHT 1 See footnote on page 9 ...

Страница 9: ... Heating Temp 1 Cooling Temp 1 MORNING MIDDAY EVENING NIGHT Friday MORNING MIDDAY EVENING NIGHT Saturday MORNING MIDDAY EVENING NIGHT 1 Heating and cooling temperatures must be at least 3 F apart for proper control in the AUTO mode ...

Страница 10: ...AUTO FAN ROOM COPY TO OFF EM HT EM HT AUX HT CHECK MANUALLY OPERATE THE THERMOSTAT CANCEL A PROGRAM PERIOD SELECT A DAY TO COPY A PROGRAM TO SET THE TIME LATER SET A COOLER TEMPERATURE CHANGE THE PROGRAM BACK TO THE LAST SETTTING SKIP THE NEXT PROGRAM PERIOD SET A WARMER TEMPERATURE SEE THE CURRENT SETTING SET THE TIME EARLIER SELECT ONE DAY S PROGRAM TO COPY TO ANOTHER DAY SELECT AND SET A PROGRA...

Страница 11: ...ammed time and temperature appear on the display If the display reads COOL press and release SET HEAT COOL key to switch to heat 2 Press and hold DAY key until MONDAY or the desired day appears in the display 3 Press and hold AHEAD or BACK key until the display shows the time you want the temperature at the comfort setting 4 Press and hold WARMER or COOLER key until the display shows the desired h...

Страница 12: ... Press and release DAY key if you do not wish to copy into the day that is flashing Note that the next day now starts to flash 6 Press and release COPY TO key again to select the day that is flashing or the DAY key to bypass it 7 Continue until all desired days are showing in the display and are not flashing 8 Press and release RUN PROGRAM key to copy the program into all the days you have selecte...

Страница 13: ...mal setting for most zones The fan goes on and off with the compressor in heat pump systems System Switch System switching positions control thermostat operation as follows EM HT The thermostat controls the backup heat only The heat pump is off HEAT The thermostat controls your heating system AUTO The thermostat controls either your heating or cooling system depending on zone temperature COOL The ...

Страница 14: ... this period is not being used To Go Back to the Temperature of the Previous Program Period Press and release CHANGE TO LAST PERIOD key The display will show the name of the previous period and flash TEMPORARY until the next regularly scheduled period starts To Temporarily Raise or Lower the Temperature for the Current Period Only Press and hold the WARMER or COOLER key until the desired temperatu...

Страница 15: ...THE THERMOSTAT This feature is particularly useful when you go on vacation or other extended absences It does not cancel your program With the system switch in the AUTO position you can alternate between heating and cooling by pressing and holding down PRESENT SETTING key Then proceed as follows 1 Press and release HOLD TEMP key 2 Press and hold temperature key WARMER or COOLER to change the tempe...

Страница 16: ...play The start time and temperature setting will appear on the display 2 Press and release DAY key to display the next daily time and temperature for that period 3 Press and release RUN PROGRAM key to return to normal operation CHECKING THE CURRENT TEMPERATURE SETTING Press a single key to compare actual zone tempera ture to the setting at any time Press and release the PRESENT SETTING key The dis...

Страница 17: ...bottom 3 Lift the thermostat up and off the base PM MIDDAY WED HEAT ON ROOM SYSTEM RUN PROGRAM TIME TEMPERATURE PRESENT SETTING SKIP NEXT PERIOD CHANGE TO LAST PERIOD SET PRESENT DAY TIME HOLD TEMP DAY SET HEAT COOL CANCEL PERIOD COPY FROM AHEAD WARMER COPY TO BACK COOLER PERIOD M8366 HEAT COOL OFF ON AUTO FAN M3760 AUTO HEAT EM HT AUTO COOL OFF ON AUTO FAN M8370 ...

Страница 18: ...n place 3 Tighten the captive screws M3757 PM RETURN MON HEAT ON SYSTEM AUTO HEAT EM HT AUTO COOL OFF ON AUTO FAN M8365 PM MIDDAY WED HEAT ON ROOM SYSTEM RUN PROGRAM TIME TEMPERATURE PRESENT SETTING SKIP NEXT PERIOD CHANGE TO LAST PERIOD SET PRESENT DAY TIME HOLD TEMP DAY SET HEAT COOL CANCEL PERIOD COPY FROM AHEAD WARMER COPY TO BACK COOLER PERIOD M8367 ...

Страница 19: ...from the wall See page 17 Lift the batteries out of the holder Insert the new batteries making sure the positive terminals all face toward the right Replace the thermostat on the wall See page 18 Reprogram if necessary POWER OUTAGES Backup batteries will hold the programming and keep the display on during most power outages Once the power is restored the system will resume normal operation If the ...

Страница 20: ...er cooling temperature that lets you save on heating and cooling costs when you re asleep or away Also called the setback heating or setup cooling temperature Preprogrammed schedule This is the schedule programmed into your thermostat at the factory It sets a night program that provides energy savings if you don t set your own program or if your personal schedule is lost for any reason This progra...

Страница 21: ...gy saving temperature Setup Raising the temperature in the zone for a set period every day in summer for energy savings The higher temperature is the energy saving temperature Setpoint The thermostat temperature setting you select The thermostat turns the heating or cooling equipment on and off to maintain this temperature at the thermostat location until another temperature setting setpoint goes ...

Страница 22: ...e for daytime energy savings if the zone is unoccupied EVENING The time period when you want the zone at a comfortable temperature for evening activities after daytime energy savings NIGHT The time period when you can set back winter or up summer the temperature for energy savings because family members are asleep or the building is unoccupied Often a NIGHT energy savings temperature is set only f...

Страница 23: ... the COOL temperature setting is at least 3 F above the HEAT temperature setting Display flashes during Programming has been lost because of a power outage You must reprogram operation Program is lost due to Check that backup batteries are installed correctly Replace if necessary power outage Reprogram the thermostat Temperature change occurs Check the program times for the period in question Be s...

Страница 24: ...heating equipment Allow up to ten minutes after changing the setting before the compressor starts If temperature setting is higher than current temperature and display says HEAT ON or SYSTEM light is on contact your heating and air conditioning contractor Cooling will not come on Check the fuse or circuit breaker and replace or reset if necessary Check that switch on thermostat is set to COOL or A...

Страница 25: ...and the fan to come on before SYSTEM light is on but no checking for heat at the register heat is coming from the registers Display flashes REPL BAT Install fresh alkaline batteries We recommend Energizer batteries or goes blank when power is turned off When I press the PRESENT Press and hold PRESENT SETTING to alternate between heating and cooling SETTING key I only see the temperatures heating t...

Страница 26: ...IGHT 22 Operating Your Thermostat 14 PERMANENTLY CHANGING THE PROGRAM 15 POWER OUTAGES 19 Preprogrammed schedule 20 Program 20 Program Schedule 7 PROGRAMMING 6 Programming Your Thermostat 6 Recovery 21 REMOVING THE THERMOSTAT 17 REPLACING THE BATTERIES 19 REPLACING THE THERMOSTAT 18 Set Current Day and Time 11 Setback 21 Setpoint 21 SETTING THE SYSTEM AND FAN SWITCHES 13 Setup 21 SYSTEM light 21 S...

Страница 27: ...in the possession of a consumer Honeywell Trol A Temp s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL TROL A TEMP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some...

Страница 28: ...28 69 0819 Printed in Taiwan ...