background image

T8400C1099, T8401C1031 ELECTRONIC THERMOSTATS

5

69-1484-2

SYSTEM Switch

System switch settings control thermostat operation as 
follows:

Cool: The thermostat controls the cooling system.
Off: Both heating and cooling are off.
Heat: The thermostat controls the heating system.

Slide the SYSTEM switch in the bottom right corner of 
the thermostat to select the desired system setting.

Fig. 12. Digital display and system 

switches (FAN and SYSTEM).

Set Temperature Setpoint

NOTE: Temperature setpoint range is 40° to 99°F (5° to 

37°C).

The temperature setpoint and the room temperature are 
shown separately on the digital display. The 

 indicator 

points to 

Set

 when the temperature setpoint is displayed 

and to 

Room

 when the room temperature is displayed.

.

To set temperature setpoint:

1.

Select Heat or Cool by sliding the SYSTEM switch 
in the lower right corner of the thermostat to the 
desired mode. See Fig. 12.

2.

To display the temperature setpoint on the digital 
display, press either the 

 or 

 key once. The tem-

perature setpoint is displayed for approximately 
five seconds as the indicator points to 

Set

 and 

flashes.

3.

To increase the temperature setpoint press the 

 

key. Each press changes the setpoint one degree; 
press and hold to change the setpoint several 
degrees.

4.

To decrease the temperature setpoint press the 

 

key. Each press changes the setpoint one degree; 
press and hold to change the setpoint several 
degrees. 

Setting °F/°C Indication and Heat Cycle Rate

NOTE: To save changes to the °F/°C indication, the 

heat cycle rate and the C3/C1 temperature  
control, tap the 

 key until exiting the installer 

setup.

To set the °F/°C indication, the heat cycle rate and the 
C3/C1 temperature control:

1.

If the temperature is displayed in °F, set the tem-
perature setpoint to 52°F. If the room temperature 
is displayed in °C, set the temperature setpoint to 
11°C. 

OPTIONAL SYSTEM CHECKOUT 

When in steps 2 and 3 only, the 

 key can be used to 

turn heat or cool outputs on and off. Change the 
SYSTEM switch setting to test heat or cool outputs. No 
action takes place If the system switch is in the Off 
position.

Examples: System setting at HEAT: If heat is on, the 

 

key turns it off; if heat is off, 

 turns it on.

System setting at COOL: If cool is on, 

 key 

turns it off; if cool is off, 

 turns it on.

2.

Press the 

▲▼

 keys simultaneously for more than 

one second to light all segments on display and to 
enter installer setup mode. When the keys are 
released, a two-digit software revision code is dis-
played.

SYSTEM

Cool  Off  Heat

Auto  On

FAN

M14678

TEMPERATURE DISPLAY

INCREASE SETTING

DECREASE SETTING

FAN SWITCH

SYSTEM SWITCH

Set

Room  

INDICATOR

ROOM TEMPERATURE

SETPOINT TEMPERATURE

M14679

M14680

M14681

M14682

M14683

M14684

M14685

M14686

Содержание T8400C1099

Страница 1: ... Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power su...

Страница 2: ...e maximum wire to wire the T8400 and T8401 Thermostats All wiring must comply with local electrical codes and ordinances Disconnect the power supply to prevent electrical shock or equipment damage NOTE To ensure proper mounting of thermostat restrict all wiring to the shaded area See Fig 4 The shape of the terminals permits insertion of straight or wraparound wiring connections either method is ac...

Страница 3: ...SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED FACTORY INSTALLED JUMPER M13275 Y G Rc W R B O 2 2 Y G Rc W 2 4 R B O M12562A L1 HOT L2 FAN RELAY HEAT RELAY L1 HOT L2 COMPRESSOR CONTACTOR HEATING TRANSFORMER COOLING TRANSFORMER HEAT DAMPER COOL DAMPER 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSF...

Страница 4: ...ent In heating the fan is controlled directly by the heating equipment and may start a few minutes after the heating equipment turns on on most systems When using an electric heat thermostat the fan starts and stops with the heating equipment Slide the FAN switch in the bottom left corner of the thermostat to select the desired fan setting L1 HOT L2 1 FAN RELAY COOL RELAY HEAT RELAY 24V M20881 TRA...

Страница 5: ... degrees 4 To decrease the temperature setpoint press the key Each press changes the setpoint one degree press and hold to change the setpoint several degrees Setting F C Indication and Heat Cycle Rate NOTE To save changes to the F C indication the heat cycle rate and the C3 C1 temperature control tap the key until exiting the installer setup To set the F C indication the heat cycle rate and the C...

Страница 6: ...OTE After exiting installer setup mode slide the System switch to the desired position and change the setpoint to the desired room temperature CHECKOUT Heating 1 Slide the SYSTEM switch to Heat and the FAN switch to Auto 2 Press and hold the key to raise the temperature setting several degrees above the room tempera ture After approximately ten seconds the heating equipment should start In convent...

Страница 7: ...M switch to Off and the FAN switch to On The fan should run continuously 2 Slide the FAN switch to Auto In heating the fan is controlled directly by the heating equipment and may start a few minutes after the heating equip ment turns on on most systems When using an electric heat thermostat the fan starts and stops with the heating equipment In cooling the fan starts and stops with the cooling equ...

Страница 8: ...www honeywell com yourhome T8400C1099 T8401C1031 ELECTRONIC THERMOSTATS Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: