background image

69-1711    J.S. 2-04 

www.honeywell.com/yourhome

T822 THERMOSTAT

Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.

Automation and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN  55422

Scarborough, Ontario
M1V 4Z9

IF YOU HAVE A PROBLEM

Customer Assistance

Please read and follow the provided instructions for this 
thermostat. For additional information, go to 

www.honeywell.com/your home 

or call Honeywell 

Customer Care at 1-800-468-1502.

Before calling, please have the following information 
available:
• Thermostat model number and date code (refer to 

Fig. 6 for the location of the model number and date 
code).

• Type of heating system (for example: gas or oil; warm 

air, hot water). 

If. . .

Then. . .

Heating system 
does not come on.

Make sure the temperature 
setting is above the room 
temperature.

Make sure the circuit breaker 
is not tripped and reset it if 
necessary.

Make sure the power switch at 
the equipment is in the On 
position.

Wait 5 minutes for the system 
to respond.

Heating system runs 
too long to maintain 
a comfortable 
temperature.

Verify the thermostat is level.

Adjust heat anticipator lever 
clockwise one scale mark (see 
Fig. 7). Do not adjust heat 
anticipator below .3 Amps.

Heating system 
needs to run longer 
to maintain a 
comfortable 
temperature.

Verify the thermostat is level.

Adjust heat anticipator lever 
counterclockwise, in the 
direction of the arrow, one 
scale mark (see Fig. 7).

Temperature lever 
cannot be set to the 
highest and/or 
lowest setting on the 
temperature scale.

Adjust temperature range 
stops (see Fig. 8).

Содержание T822

Страница 1: ...off remove any screws that may fasten the cover to the thermostat 3 Locate the heat anticipator scale and the heat anticipator lever on the old thermostat see Fig 1 Fig 1 Heat anticipator on old thermostat example 4 Record the number that the heat anticipator lever points to on the heat anticipator scale NOTE If you cannot find the heat anticipator setting on your thermostat you can use a standard...

Страница 2: ... the R terminal and the other wire to the W terminal see Fig 4 and 5 4 Plug the hole in the wall with insulation to prevent a warm or cool draft from affecting the operation of the thermostat Fig 3 Remove cover on new thermostat Fig 4 R and W terminals on new thermostat Fig 5 Wraparound and straight wiring connections STEP 4 MOUNT NEW THERMOSTAT TO WALL 1 Position the thermostat on the wall Place ...

Страница 3: ... Fig 7 STEP 6 OPERATING NEW THERMOSTAT 1 Adjust the temperature setting lever to your desired setting If it is too warm lower the temperature set ting If it is too cool raise the temperature setting STEP 7 ADJUSTABLE RANGE STOPS 1 The T822 Thermostat comes equipped with adjust able range stops see Fig 8 The range stops are factory set to allow for maximum adjustment of the temperature lever If you...

Страница 4: ...r and date code Type of heating system for example gas or oil warm air hot water If Then Heating system does not come on Make sure the temperature setting is above the room temperature Make sure the circuit breaker is not tripped and reset it if necessary Make sure the power switch at the equipment is in the On position Wait 5 minutes for the system to respond Heating system runs too long to maint...

Отзывы: