background image

2

Fig. 3—T822A,D and T8022D in typical oil
heating application.

Fig. 4—T822F in typical heating application.

Fig. 5—T822G in typical heating or cooling
application.

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

T822D, T8022D ADJUSTABLE HEAT ANTICIPATOR SHOWN.  T822A 
HAS A FIXED HEAT ANTICIPATOR.

M1184A

T822A,D; T8022D

1

1

L1
(HOT)

L2

R

TEMP. FALL

W

H1

H1
ANTICIPATOR

OIL
PRIMARY

T

T

2

2

3

3

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

ALTERNATE LIMIT CONTROL LOCATION.

T822D, T8022D ADJUSTABLE HEAT ANTICIPATOR SHOWN.  T822A 
HAS A FIXED HEAT ANTICIPATOR.

M1164B

T822A,D; T8022D

1

1

L1
(HOT)

L2

LIMIT
CONTROL

R

TEMP. FALL

W

H1

2

H1
ANTICIPATOR

ELECTRIC
HEAT RELAY

2

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

T822D, T8022D ADJUSTABLE HEAT ANTICIPATOR.  T822A HAS A 
FIXED HEAT ANTICIPATOR.

M1183A

T822A,D; T8022D

1

1

L1
(HOT)

L2

R

TEMP. FALL

W

H1

H1
ANTICIPATOR

GAS
CONTROL

2

2

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

M5538

T822F

L1
(HOT) L2

TEMP. FALL

H1

H1
ANTICIPATOR

R

G

W

FAN RELAY

HEAT RELAY

1

FAN 
SWITCH

ON

AUTO

1

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

M5512

T822G

L1
(HOT) L2

TEMP. FALL

H1

H1
ANTICIPATOR

R

Y

W

COOL RELAY

HEAT RELAY

1

1

C1

C1
ANTICIPATOR

2

USE EITHER "W" OR "Y" TERMINAL, BUT NOT BOTH.

2

4. Remove thermostat cover by pulling outward on

bottom edge of cover until it snaps free of the thermostat
base. Carefully remove and discard the foam plastic ship-
ping insert. This insert protects the switch and bimetal
assembly during shipping.

5. Set the adjustable heat anticipator indicator

(T822D,F,G only) to match the current draw of the primary
heating control (see Heat Anticipator Setting).

6. Push excess wire back through the hole and plug any

opening with insulation to prevent drafts that may affect
thermostat performance.

7. Loosely fasten the thermostat to the wall or outlet

box with a screw through the top mounting hole. Do not
tighten.

8. Level the thermostat exactly using a spirit level or

plumb line. Tighten the mounting screws.

IMPORTANT:  An incorrectly leveled thermostat will

cause the temperature control to deviate from setpoint.

9. Replace the thermostat cover.

Fig. 1—T822A,D and T8022D in typical electric
heating application.

Fig. 2—T822A,D and T8022D in typical gas
heating application.

Содержание T8022D

Страница 1: ...ion T822A D F TS822A and T8022D Thermostats pro vide control of heating systems T822G provides control of AC heating or cooling appliances The T822A two wire switch thermostat provides low voltage control of heating systems and features a fixed heat anticipator The T822D and T8022D two wire mercury switch thermostat provides low voltage control of heating systems and features an adjustable heat an...

Страница 2: ...R R G W FAN RELAY HEAT RELAY 1 FAN SWITCH ON AUTO 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED M5512 T822G L1 HOT L2 TEMP FALL H1 H1 ANTICIPATOR R Y W COOL RELAY HEAT RELAY 1 1 C1 C1 ANTICIPATOR 2 USE EITHER W OR Y TERMINAL BUT NOT BOTH 2 4 Remove thermostat cover by pulling outward on bottom edge of cover until it snaps free of the thermostat base Carefully remove a...

Страница 3: ...d mount the thermostat Continue with system checkout NOTE For best performance the heat anticipator may require further adjustment To lengthen burner on time move the indicator in the direction of the longer ar rows not more than one half scale marking at a time To shorten burner on time move indicator in opposite direction Checkout CAUTION CAUTION Do not check thermostat operation by shorting acr...

Страница 4: ...ppears necessary proceed as follows 1 Placethetemperaturesettingleveratthesamesetting as the thermometer Remove cover 2 Insert104994ACalibrationWrench orderseparately onto the hex nut under the coil See Fig 7 Holding the setting lever so it does not move turn the wrench clock wise until the switch just breaks contact Remove wrench and replace cover 3 Move the setting lever to a low setting Wait at...