
MU1H-1366GE23 R0609
6
Honeywell GmbH
GB
1. Safety Guidelines
1. Follow the installation instructions.
2. Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the
applications detailed in these installation instruc-
tions. Any other use will not be considered to comply
with requirements and would invalidate the
warranty.
4. Please take note that any assembly, commis-
sioning, servicing and adjustment work may only be
carried out by authorized persons.
5. Immediately rectify any malfunctions which may
influence safety.
2. Functional description
Diaphragm safety valves of this type are directacting
safety valves in which the disc is pushed up by the
pressure from the system against a spring which is
holding the valve closed. If the opening force exceeds
the force exerted by the spring, then the valve disc is
lifted off the valve seat and the valve discharges the
medium. In accordance with the requirements of the
standard, the full discharge capacity of the valve will be
achieved when the system pressure climbs to no more
than 10% above the set pressure of the valve. Full
shutoff must be achieved if the system pressure falls to
below 80% of the nominal set pressure of the valve.
For valves rated up to 3.0 bar, the closing pressure can
be taken as 0.6 bar minimum.
3. Application
The membrane safety valve is only suitable to drain the
following media from closed heating systems accor-
ding to EN 12828 for protection against exceeding
pressure
4. Technical data
5. Options
6. Scope of delivery
The safety valve comprises:
• Angled housing
• Adjustment spring
• Diaphragm
• Security cap with part label
Medium Water or glycol-water mixture,
according to VDI 2035
Liquids of the fluid group 1 and 2 (pressure
device guideline, item 9) which do not affect
the materials used.
Installation position Horizontal with safety cap pointing up
Opening pressure Factory preset to 1.5, 2.0, 2.5, 3.0,
4.0 or 6.0 bar
Subsequent alteration of the setting
is not permitted and is impossible
without destroying the security cap
Operating tempera-
ture
Max. 120 °C
Connection size
Internal thread on inlet
1
/
2
",
3
/
4
",
Internal thread on outlet
1
/
2
",
3
/
4
", 1"
External thread on inlet
1
/
2
" with
internal thread on outlet
3
/
4
"
Valve size is defined by the size of
the inlet connection
OS.-No.
Set pres-
sure
Connection
size Inlet
Connection
size Outlet
SM110- 1/2ZA2.5 2.5 bar Rp
1
/
2
" IG Rp
1
/
2
" IG
SM110- 1/2ZA3.0 3 bar
Rp
1
/
2
" IG Rp
1
/
2
" IG
SM110- 1/2A1.5
1.5 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 1/2A2.0
2.0 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 1/2A2.5
2.5 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 1/2A3.0
3.0 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 1/2A4.0
4.0 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 1/2A6.0
6.0 bar Rp
1
/
2
" IG Rp
3
/
4
" IG
SM110- 3/4ZA2.5 2.5 bar Rp
3
/
4
" IG Rp
3
/
4
" IG
SM110- 3/4ZA3.0 3.0 bar Rp
3
/
4
" IG Rp
3
/
4
" IG
SM110- 3/4A1.5
1.5 bar Rp
3
/
4
" IG Rp1" IG
SM110- 3/4A2.5
2.5 bar Rp
3
/
4
" IG Rp1" IG
SM110- 3/4A3.0
3.0 bar Rp
3
/
4
" IG Rp1" IG
SM110- 3/4A4.0
4.0 bar Rp
3
/
4
" IG Rp1" IG
SM110- 1/2AA1.5 1.5 bar Rp
1
/
2
" AG Rp
3
/
4
" IG
SM110- 1/2AA2.0 2.0 bar Rp
1
/
2
" AG Rp
3
/
4
" IG
SM110- 1/2AA3.0 3.0 bar Rp
1
/
2
" AG Rp
3
/
4
" IG