Honeywell SLATE Скачать руководство пользователя страница 9

SLATE

 

FUEL AIR RATIO MODULE

 

9

R8001C6001

IMPORTANT

1. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance 
with these instructions, may cause 

interference for radio 

communications. It has been tested and found to comply 
with the limits of a Class A computing device of part 15 
of FCC rules, which are designed to provide reasonable 
protection against such interference when operated in a 
commercial environment. Operation of this equipment in a 
residential area may cause interference; in which case, the 
user, at their own expense, may be required to take whatever 
measures are required to correct this interference.

2. This digital apparatus does not exceed the Class A limits for 

radio noise, set out in the Radio Interference Regulations of 
the Canadian Department of Communications.

3. Cable shield must be terminated to ground at both ends. If 

shielded cable is NOT used, use three-wire twisted cable.

WARNING

Fire or Explosion Hazard  
Can cause severe injury, death, or property damage.

Disconnect the power supply from the main disconnect 
before beginning installation to prevent electrical shock 
and equipment damage. More than one disconnect can 
be required.

Содержание SLATE

Страница 1: ...SLATE Fuel Air Ratio Module R8001C6001 INSTALLATION INSTRUCTIONS ...

Страница 2: ...Scan for more information ...

Страница 3: ... airflow and flue gas recirculation on a power burner Features Within the SLATE system the fuel air ratio module provides Air fuel ratio control for up to 4 actuators Drive 2 Variable Frequency Drives VFDs RS 485 Modbus communications to communicate to the actuators and receive feedback SLATE actuator torque sizes 50 in lb NEMA 1 and NEMA 4 150 in lb NEMA 1 and NEMA 4 300 in lb NEMA 4 900 in lb NE...

Страница 4: ...y See Tables 1 5 Environmental Ratings Ambient Temperature Operating 20 F to 150 F 29 C to 66 C Shipping 40 F to 150 F 40 C to 66 C Humidity 95 continuous noncondensing Vibration 0 5G environment Dimensions See Fig 1 Weight 13 6 oz 0 39 Kg Approvals Underwriters Laboratories Inc Listed File MP268 Factory Mutual IRI Acceptable Federal Communications Commission Part 15 Class A Must be mounted inside...

Страница 5: ... R8001B2001 SLATE Burner Control Module Fig 1 M35382 4 19 32 117 7 3 32 181 2 11 16 68 Dimensions in in mm Principal Technical Features The R8001C6001 fuel air ratio module monitors and controls the air fuel ratio for combustion applications ...

Страница 6: ...Description Power No light System does not have power Green System has power CPU Red No valid configuration Green Running Fault Red Fault No light No fault Table 1 LED Descriptions LED Displays The SLATE system modules have three character LED displays used for indicating the module number of the SLATE system They also have three position LED colors to indicate terminal states as shown in Table 2 ...

Страница 7: ...n of safety requirements must be performed each time a control is installed on a burner to prevent possible hazardous burner operation When Installing This Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your applicatio...

Страница 8: ...efore beginning installation to prevent electrical shock and equipment damage More than one power supply disconnect can be involved Fig 2 M35383 Installing the Fuel Air Ratio Module on the Sub Base Module 2 Wiring must comply with all applicable codes ordinances and regulations 3 Wiring must comply with NEC Class 1 Line Voltage wiring ...

Страница 9: ...sidential area may cause interference in which case the user at their own expense may be required to take whatever measures are required to correct this interference 2 This digital apparatus does not exceed the Class A limits for radio noise set out in the Radio Interference Regulations of the Canadian Department of Communications 3 Cable shield must be terminated to ground at both ends If shielde...

Страница 10: ...V INPUT OUTPUT VFD1 UNIVERSAL LOW VOLTAGE CELL _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 _ VFD2 UNIVERSAL LOW VOLTAGE CELL RS 485 A B C A B C RS 485 A B C RS 485 A B ACTUATOR 1 ACTUATOR 2 ACTUATOR 3 ACTUATOR 4 RS 485 C Wiring diagram for Fuel Air Ratio Module ...

Страница 11: ...es 2 5 for configu ration options 5 VFD2 Cell B T1 See Tables 2 5 for configu ration options 6 VFD2 Cell B T2 See Tables 2 5 for configu ration options 7 VFD2 Cell B T3 See Tables 2 5 for configu ration options 8 VFD2 Cell B T4 See Tables 2 5 for configu ration options 9 A1 A RS485 10 A1 B RS485 11 A1 C GND 12 A2 A RS485 13 A2 B RS485 14 A2 C GND 15 A3 A RS485 16 A3 B RS485 17 A3 C GND 18 A4 A RS4...

Страница 12: ...Accuracy 300 0 300 0 uA DC 0 to 25 mA 50 50 uA DC 4 to 20 mA T2 Voltage In Amplitude 0 0 15 0 VDC Trip Point 3 0 VDC Comparator Only Hysteresis 0 25 VDC Resolution 0 37 mV DC Null 25 0 25 0 mV DC Accuracy 25 0 25 0 mV DC T3 Voltage In Range 0 0 15 0 VDC Resolution 0 37 mV DC Null 25 0 25 0 mV DC Accuracy 25 0 25 0 mV DC Current In Range 0 2 25 0 mA DC Resolution 3 7 uA DC Null 0 5 0 5 mA DC Accura...

Страница 13: ...T1 T4 Type 10K Range 40 0b 175 0 C T4 rated to 0 C Resolution 0 1 C Accuracyc 2 0 2 0 C 40 C to 25 C 1 0 1 0 C 25 C to 125 C 1 5 1 5 3 0 3 0 C 125 C to 175 C T1 T3 T1 T4 Type 12K Range 20 0 125 0 C T4 rated to 0 C Resolution 0 1 C Accuracyc 2 0 2 0 C 20 C to 30 C 1 0 1 0 C 30 C to 120 C 1 5 1 5 3 0 3 0 C 120 C to 125 C T1 T3 T1 T4 Type 20K Range 25 0 150 0 C T4 rated to 0 C Resolution 0 1 C Accura...

Страница 14: ...130 0 usec 10V amplitude Duty Cycle 2 100 Hz 2 0 98 0 DC 10V amplitude 1000 Hz 5 0 85 0 DC 10V amplitude Resolution 1 0 Hz Accuracy 5 0 0 0 Whichever is greater 1 0 0 0 Hz PWM In T2 T4 Amplitudea 5 0 10 0 15 0 VDC Frequency 125 0 500 0 Hz Min on pulse width low DC 50 0 usec 10V amplitude Min off pulse width high DC 130 0 usec 10V amplitude Duty Cycle 125 500 Hz 5 0 90 0 DC 10V amplitude Resolution...

Страница 15: ...ion Lines 22 AWG two wire twisted pair with ground or five wire Belden 8723 shielded cable or equivalent Other terminals 18 AWG wire insulated for voltages and temperatures for given application TTW60C THW75C THHN90C Table 8 Recommended Wire Sizes and Part Numbers Resistance to Temperature Conversion Tables Below are the lookup tables for various types of SLATE sensors Linear interpolation is used...

Страница 16: ...3 862 3833 760 52 015 5520 614 40 972 7949 685 30 653 11447 546 20 990 19781 359 7 594 34182 189 4 636 59066 823 15 846 102067 470 26 159 176372 588 35 678 304771 832 44 491 12K NTC Ohms Degrees C 494 600 124 750 560 400 119 750 726 000 109 750 952 300 99 750 1266 000 89 750 1707 000 79 750 2337 000 69 750 3252 000 59 750 4607 000 49 750 ...

Страница 17: ... 000 9 750 36130 000 0 250 58880 000 10 250 98970 000 20 250 20K NTC Ohms Degrees C 372 200 150 000 555 080 133 250 842 660 117 050 1301 180 101 450 2047 500 86 400 3284 380 71 900 5378 420 57 850 8996 680 44 250 15345 520 31 150 26744 880 18 500 47748 920 6 250 87148 340 5 550 163394 900 17 000 260844 260 25 000 ...

Страница 18: ...520 409 750 280 962 499 750 1000 ohm RTD Ohms Degrees C 185 26 200 250 500 64 125 250 882 23 30 250 1328 01 84 750 1740 10 194 750 2138 22 304 750 2505 20 409 750 2809 62 499 750 1000 ohm Balco RTD Ohms Degrees C 779 000 40 000 864 700 15 000 956 900 10 000 1044 400 32 200 1148 900 57 200 1247 300 79 400 1350 900 101 700 1418 200 115 600 ...

Страница 19: ... 000 87 675 12600 000 232 778 28400 000 517 923 33600 000 608 497 38300 000 686 565 44300 000 781 520 51600 000 895 549 56800 000 980 638 59500 000 1026 230 Type K thermocouple microVolts Degrees C 5000 000 153 736 4400 000 129 609 3600 000 101 517 2600 000 70 403 1200 000 31 171 700 000 17 529 6500 000 159 027 11300 000 278 023 17500 000 426 066 29000 000 696 902 34500 000 829 998 39500 000 954 7...

Страница 20: ...control panel of the equipment Earth ground must be capable of conducting enough current to blow the breaker in the event of an internal short circuit 2 Use wide straps or brackets to provide minimum length maximum surface area ground conductors If a leadwire is required use 14 AWG copper wire 3 Make sure that mechanically tightened joints along the ground path are free of nonconductive coatings a...

Страница 21: ...le 3 The SLATE system must be mounted in an electrical enclosure When mounting in an electrical enclosure provide adequate clearance for servicing installation and removal of SLATE modules Maximum wire length The maximum leadwire length is 300 feet to terminal inputs Control Running Lockout Interlock For Remote Bus data lines maximum cable length depends on the number of modules connected the nois...

Страница 22: ...22 32 00006 03 ...

Страница 23: ...SLATE FUEL AIR RATIO MODULE 23 R8001C6001 ...

Страница 24: ... honeywell com U S Registered Trademark 2015 Honeywell International Inc 32 00006 03 M S Rev 05 15 Printed in U S A For more information and detailed instructions on the R8001C6001 and the entire SLATE system please refer to the SLATE User Guide located on our website at http combustion honeywell com SLATE 32 00006 03 ...

Отзывы: