Honeywell SILENT KNIGHT SK-Control-6 Скачать руководство пользователя страница 5

SK-460-006 

I56-3437-002

BASE ADDRESS

STATUS
INDICATORS

NAC

PS

NAC

PS

   

  +

+   

  —

NAC

PS

   

  +

+   

  —

NAC

PS

   

  +

+   

  —

NAC

TOP

BOT

–       +

+ N

AC

 –

–       +

– 

PS

 +

SLC

PS

   

  +

+   

  —

+1

+2

+3

+4

+5

T1

1

T10

T0

+0

T12

T1

T2

T3

T4

T5

T13

T14

T15

T16

ENABLE POWER SUPPL

Y

 MONIT

OR

DISABLE SHOR

T CIRCUIT

 PROTECTION

   

  +

+   

  —

A/B SELECT

DISABLE 1

DISABLE 2

DISABLE 3

0

1

2

3

4

5 6

7 8 9

0

7 8

6

5

4

3

2

1

9

REMOVE SHUNT FOR CLASS A.

EXTERNAL

POWER

SUPPLY

TO NEXT

DEVICE

+

+

FROM PANEL OR

PREVIOUS DEVICE

+

+

+

SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX.

SEE PANEL INSTRUCTION MANUAL

FOR WIRE REQUIREMENTS.

(–)

(+)

POWER-LIMITED
AND SUPERVISED

TOP OF T0

EOLR-1

(TYP)

RED

VIO

VIO

RED

BLK

BLK

(–)

(+)

+

10

11

12

13

14

15

C0177-04

FIGURE 8: ExAMPLE OF CLASS A, STYLE Z NAC CONFIGURATION wITh A SINGLE SUPPLY DEDICATED TO A SINGLE NAC.

BASE ADDRESS

STATUS
INDICATORS

NAC

PS

NAC

PS

   

  +

+   

  —

NAC

PS

   

  +

+   

  —

NAC

PS

   

  +

+   

  —

NAC

TOP

BOT

–       +

NA

–       +

– 

PS

 +

SLC

PS

   

  +

+   

  —

+1

+2

+3

+4

+5

T1

1

T10

T0

+0

T12

T1

T2

T3

T4

T5

T13

T14

T15

T16

ENABLE POWER SUPPL

Y

 MONIT

OR

DISABLE SHOR

T

 CIRCUIT

 PROTECTION

   

  +

+   

  —

A/B SELECT

DISABLE 1

DISABLE 2

DISABLE 3

0

1

2

3

4

5 6

7 8 9

0

7 8

6

5

4

3

2

1

9

EXTERNAL

POWER

SUPPLY

TO NEXT

DEVICE

+

+

FROM PANEL OR

PREVIOUS DEVICE

+

+

+

+

SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX.

SEE PANEL INSTRUCTION MANUAL

FOR WIRE REQUIREMENTS.

POWER-LIMITED
AND SUPERVISED

TOP OF T0

+

(–)

(+)

VIO

VIO

RED

BLK

(–)

(+)

(–)

(+)

(–)

(+)

EOLR-1

47K

47K

10

11

12

13

14

15

FIGURE 7: ExAMPLE OF CLASS B, STYLE Y NAC CONFIGURATION wITh A SINGLE SUPPLY ShARED BY 2 NACS.

C0175-05

firealarmresources.com

Содержание SILENT KNIGHT SK-Control-6

Страница 1: ... common SLC input is used for all modules Each module has its own address A pair of rotary code switches is used to set the address of the first module from 01 to 154 The remaining modules are automatically assigned to the next five higher addresses Provisions are included for disabling a maximum of three unused modules to release the addresses to be used elsewhere Each module also has panel contr...

Страница 2: ... each chassis are offset below the rear SK Control 6 module positions so that all of the status indicators are vis ible For cabinet dimensions refer to the IDP ACB instruction manual INSTALLATION STEPS 1 Cabinet Mounting In a clean dry area mount the backbox using the four holes provided in the back surface of the cabinet Figure 3 Figure 1 IDP ACB Cabinet Figure 2 Typical mounting hole locations B...

Страница 3: ...l be enabled The SK Control 6 must have power cycled for shunt changes to take effect 5 There is an active short circuit protection option for each address The board is shipped with this option disabled for each address represented by six large shunts on the Disable Short Circuit Protection area To C0226 00 Figure 4b Installation of SK Control 6 module in front chassis position enable short circui...

Страница 4: ...AL POWER SUPPLY TO NEXT DEVICE FROM PANEL OR PREVIOUS DEVICE SIGNAL LINE CIRCUIT SLC 32 VDC MAX SEE PANEL INSTRUCTION MANUAL FOR WIRE REQUIREMENTS POWER LIMITED AND SUPERVISED TOP OF T0 EOLR 1 RED VIO VIO RED BLK BLK 47K TABLE 4 JUMPER LOCATION NAC PAIR SHARING SUPPLY T11 0 and 1 T12 1 and 2 T13 2 and 3 T14 3 and 4 T15 4 and 5 NOTE Jumpers must be placed on T11 T13 and T15 for all Class A Style Z ...

Страница 5: ...12 13 14 15 C0177 04 Figure 8 Example of Class A Style Z NAC configuration with a single supply dedicated to a single NAC BASE ADDRESS STATUS INDICATORS NAC PS NAC PS NAC PS NAC PS NAC TOP BOT NAC PS SLC PS 1 2 3 4 5 T11 T10 T0 0 T12 T1 T2 T3 T4 T5 T13 T14 T15 T16 ENABLE POWER SUPPLY MONITOR DISABLE SHORT CIRCUIT PROTECTION A B SELECT DISABLE 1 DISABLE 2 DISABLE 3 0 1 2 3 4 5 6 7 8 9 0 7 8 6 5 4 3...

Страница 6: ...ese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa tion I...

Отзывы: