La liaison Centrale/Sirène étant bidirectionnelle, il est préférable d’enregistrer la 
SIX00HF à son emplacement définitif, pour s’assurer de son bon fonctionnement et 
d’une portée radio correcte.  

1

 - Connectez l’outil de configuration et entrez en 

programmation. 

2

 - Choisissez la rubrique « ENREGISTREMENT»  (puis 

«Sirène» pour les centrales CRT500) 
 

3

 - Ouvrez le capot de la sirène. Elle se déclenche dès l’ouverture (autoprotection). 

4

 – Appuyez sur le bouton « INIT » (2) pendant 2s. La phase d’initialisation matérialisée 

par des bips, dure 20 secondes (autoprotection ouverte). 

5

 – Lorsque la sirène est enregistrée, les bips sonores s’arrêtent et elle émet un signal 

2 tons. Sur l’afficheur de l’outil de programmation est indiqué l’identification de la 
sirène, puis s’affiche « sirène enregistrée » avec le niveau radio reçu 

6

 - Tapez sur la touche QUIT pour sortir du mode programmation. 

 

IMPORTANT : la sirène doit toujours être enregistrée à son 

emplacement définitif avec un minimum de réception de 2/10

 

Remarque : Dans le cas d’une suppression, il est nécessaire d’appuyer sur le contact 
d’autoprotection de la sirène pour arrêter les bips. 

 

 

 

 

 

C

C

H

H

A

A

N

N

G

G

E

E

M

M

E

E

N

N

T

T

 

 

D

D

E

E

S

S

 

 

P

P

I

I

L

L

E

E

S

S

 

 

1

 - Ouvrez le capot de la sirène, le déclenchement de l’autoprotection la fait sonner 

(pendant 1 s.). Retirer les piles (à jeter dans les containers prévus à cet effet). 

2

 - Insérer les nouvelles piles lithium 3V de type CR123 (en respectant les polarités) 

3

 – Appuyer sur le bouton « initial » (2). La sirène émet un signal 2 tons signalant 

qu’elle est de nouveau en service. 

4

 - Remonter le capot, en vissant les deux vis. La sirène est prête à fonctionner  au 

bout de 10 secondes

.

 

 

Avant de procéder  au remplacement des piles, sortir du mode 

programmation pour la ré-initialisation du défaut pile. 

 
 

ATTENTION : Il y a danger d'explosion s'il y a remplacement incorrect de la pile. 
Remplacer uniquement avec une pile du même type ou d'un type équivalent 
recommandé par le constructeur. Mettre au rebut les piles usagées 
conformément aux instructions du fabricant.

 

 
 

C

C

A

A

R

R

A

A

C

C

T

T

E

E

R

R

I

I

S

S

T

T

I

I

Q

Q

U

U

E

E

S

S

 

 

Techniques 

Alimentation  

3 piles 3v type CR 123  pour SI500 

4 piles 3v type CR 123  pour SI800 

Autonomie  

> 4 ans typique 

Autoprotection  

A l’ouverture et arrachement 

Puissance 

95, 110, 114, 115, 116, 118 ou mode progressif (valeurs pouvant varier de ±2dBA) 

Température 

De fonctionnement : 0° à 40°C. 

Température  

de stockage :  -20° à +70°C. 

Diamètre  

165mm 

Poids  

430g. 

Couleur  

Blanc 

Radio 

Type 

FM  bande étroite : 
 
224,5 MHz pour les séries SI500HF 

Fréquences 

868,25 MHz pour la série SI800HF 

Portée radio  

> 50m sur site. 

Supervision Oui 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

R

R

E

E

C

C

O

O

R

R

D

D

I

I

N

N

G

G

 

 

The Control Panel / Sounder link being bi-directional, sounder SI X00 HF should be 
recorded from its final location so as to secure suitable operation. 

 

1

 – With the programming tools enter to the 

programming sounder menu. 

2

 - Select "REC" (or "DELETE" if applicable). 

Message "PRESS INIT BUTTON" is displayed on the 
screen.  

3

 - Remove the sounder cover. The sounder triggers upon opening (tamper). 

4

 - Press Initial button (2) on the sounder for 2 seconds : the initialisation phase  

confirmed by beeps, lasts 20 seconds (tamper opened). 

5

 - When recording is completed the sounder stops beeping and sends a 2-tone signal. 

The sounder identification is displayed on the programming tool, then "Sounder 
recorded" comes on together with the received radio signal strength. 

6

 – Press « QUIT » key to get out of program mode. 

 

IMPORTANT : The detector must always be recorded in his final location 

with radio level better than 2/10 units

 

Note : When a sounder is being deleted, it is necessary to act on the tamper contact to 
stop the audible signal 

 
 
 

 

R

R

E

E

P

P

L

L

A

A

C

C

I

I

N

N

G

G

 

 

T

T

H

H

E

E

 

 

B

B

A

A

T

T

T

T

E

E

R

R

I

I

E

E

S

S

 

 

1

 - Remove sounder cover. Its tamper contact triggers sounding (during 1s.). Dispose of 

the batteries in a special container. 

2

 - Replace by the new lithium batteries 3V type CR123 (respecting polarity). 

3

 - Press "Initial" button (2). The sounder sends a 2-tone signal confirming it is back in 

service. 

4

 - Secure cover back in place using the two screws. The sounder is ready to operate 

after 10 seconds.

 

 

Get out program mode before removing batteries to send the end of 

battery default to the control panel. 

 
 

WARNING : Risk of explosion in case of wrong replacement of the battery. 
Replace only with a same battery type or with an equivalent type which has 
been recommended by the manufacturer. Throw the used batteries out 
according with the manufacturer instructions.

 

 
 

M

M

A

A

I

I

N

N

S

S

 

 

C

C

H

H

A

A

R

R

A

A

C

C

T

T

E

E

R

R

I

I

S

S

T

T

I

I

C

C

S

S

 

 

Technical 

Power supply  

3 batteries 3v type CR 123  for SI500 
4 batteries 3v type CR 123  for SI800 

Self-sufficiency 

> 4 years typical 

Tamper  

opening and wrenching-off 

Sound power 

95, 110, 114, 115, 116, 118 ou progressive mode (the values can change in ±2dBA) 

Temperature 

Operating : 0° à 40°C (32°F to 104°F) 

Temperature  

Storage :  -20° à +70°C (-4°F to 158°F) 

Diameter 6.50 

‘’ 

Weight  

430g. 

Color  

White 

Radio 

Type 

FM  narrow range : 
 
224,5 MHz for SI500HF series 

Frequencies 

868,25 MHz for  SI800HF series 

Radio range 

> 50m on site. 

Supervision Yes 

 

*

 

(15(*,675(0(17
6LUgQHHQUHJ
1bVHULH)

„„„„„„„†

68,7(

*

 

5(&25'
UHFRUGHG6LUHQ
VHULDO1)

„„„„„„„†

1(;7

N° de  série de l’appareil / serial number 

Cause du retour / cause of return 

Défaut constaté / noticed fault 

Description du défaut / Fault description 

Installateur / Installer 

Effraction --------------  Intrusion   

   A l’installation ------   During installation --- date 

Rénovation ------------  Cosmetic repair 

   Sur intervention ---  On intervention ------ date 

Panne -------------------  Fault 

 

   Défaut aléatoire ----  Random fault

 

A compléter et à joindre au produit lors de son retour en SAV. Tout 
produit retourné sans cette fiche entraînera son diagnostic complet 
et, en conséquence, une facturation forfaitaire pour la prestation de 
remise en état. 

To fill in and return together with the faulty product. Any reception without 
« Repair Sheet » attached to the equipment, will result in a full process 
diagnosis, repair and test. A fixed price repair would consequently apply. 

F

F

I

I

C

C

H

H

E

E

 

 

D

D

E

E

 

 

R

R

E

E

T

T

O

O

U

U

R

R

 

 

S

S

A

A

V

V

 

 

 

 

R

R

E

E

P

P

A

A

I

I

R

R

 

 

S

S

H

H

E

E

E

E

T

T

 

 

 

Отзывы: