Honeywell RV260 Series Скачать руководство пользователя страница 4

MU1H-1238GE23 R1215

4

Honeywell GmbH

GB

1. Safety Guidelines

1. Follow the installation instructions.
2. Use the appliance

• according to its intended use
• in good condition
• with due regard to safety and risk of danger.

3. Note that the appliance is exclusively for use in the appli-

cations detailed in these installation instructions. Any 
other use will not be considered to comply with require-
ments and would invalidate the warranty.

4. Please take note that any assembly, commissioning, 

servicing and adjustment work may only be carried out by 
authorized persons.

5. Immediately rectify any malfunctions which may influence 

safety.

2. Description of function

Spring loaded check valves have a moving seal disc which is 
lifted off the seat by a greater or lesser amount depending on 
the flow rate through the valve. If the flow falls towards zero, 
then the spring pushes the disc back onto the seat and seals 
the waterway.
To ensure continuing correct function it is recommended that 
check valves be regularly checked and maintained (as speci-
fied in EN 1717).

3. Application

4. Technical data

4.1. RV260

4.2. RV260LFA

5. Options

6. Scope of delivery

The check valve comprises:
• Check valve insert
• Union nut with internal thread
• Male threaded union with flat wrench faces
• Test plug with seal ring

7. Assembly

7.1. Installations Guidelines

• Installation in horizontal or vertical pipeline possible

- The horizontal installation position with a downward 

facing test valve ensures optimum drainage

• Install shutoff valves

- Shutoff valves provide optimal serviceability

• Ensure good access

- Simplifies maintenance and inspection

7.2. Assembly instructions

1. Thoroughly flush pipework
2. Close shutoff valve on inlet
3. Release pressure on outlet side (e.g. through water tap)
4. Close shutoff valve on outlet
5. Fit check valve for example between water meter and 

pressure reducing valve, filter or filter combination
• Note flow direction
• Install without tension or bending stresses

6. Slowly open shut off valves on inlet and outlet

8. Maintenance

8.1. Inspection

8.1.1. Check valve

1. Close shutoff valve on inlet
2. Open test valve

• Until the pressure is released, some water will flow out 

of the test valve. After a short period of time the water 
flow should stop. If the water continues to drip or run, 
then the check valve must be replaced - see servicing 
of check valve

3. Close test valve again
4. Slowly open shutoff valve on inlet

8.2. Maintenance

8.2.1. Check valve

1. Close shutoff valve on inlet
2. Release pressure on outlet side (e.g. through water tap)
3. Close shutoff valve on outlet
4. Replace check valve
5. Slowly open shut off valves on inlet and outlet

Medium

Water

Max. inlet pressure

10.0 bar

Operating temperature 5...40 °C
Operating pressure

approx. 0.03 bar

Connection size

Male threaded union R

3

/

4

"

Female threaded union G1"

Operating temperature 5...40 °C
Operating pressure

approx. 0.03 bar

Connection size

Male threaded union R

1

/

2

" - R2“

Female threaded union G

3

/

4

" - G2

1

/

2

"

RV260-3/4AA =

short version, dezincification-resis-
tant brass

RV260-3/4AS =

short version, dezincification-resis-
tant brass

RV260-...LFA

long version, lead free brass

Connection size

Interval: once a year

To be carried out by an installation company

Содержание RV260 Series

Страница 1: ...gsanvisning Anleitung zum späteren Gebrauch aufbewahren Keep instructions for later use Vejledning opbevares for senere brug Ta vare på bruksanvisningen for senere bruk Förvara bruksanvisningen för senare användning Rückflussverhinderer Check valve Kontraventil Tilbakeslagsventil Backventil 32304464 001 ...

Страница 2: ...waagerechte Einbaulage mit einem nach unten gerichteten Prüfventil gewährleistet eine optimale Entleerung Absperrventile vorsehen Mit Absperrventilen ist ein optimaler Service gewährlei stet Auf gute Zugänglichkeit achten Vereinfacht Wartung und Inspektion 7 2 Montageanleitung 1 Rohrleitung gut durchspülen 2 Absperrarmatur eingangsseitig schließen 3 Ausgangsseite druckentlasten z B durch Wasser za...

Страница 3: ...e aus bleifreiem Messing Überwurfmutter aus entzinkungsbeständigem Messing Einsteckrückflussverhinderer aus hochwertigem Kunst stoff Dichtungen aus NBR und Kupfer Prüfschraube aus bleifreiem Messing 10 Serviceteile 10 1 RV260 10 2 RV260LFA Durchführung durch ein Installationsunternehmen Die örtlichen Vorschriften zur ordnungsgemäßen Abfallverwertung bzw Beseitigung beachten Nr Bezeichnung Nennweit...

Страница 4: ...ff valves Shutoff valves provide optimal serviceability Ensure good access Simplifies maintenance and inspection 7 2 Assembly instructions 1 Thoroughly flush pipework 2 Close shutoff valve on inlet 3 Release pressure on outlet side e g through water tap 4 Close shutoff valve on outlet 5 Fit check valve for example between water meter and pressure reducing valve filter or filter combination Note fl...

Страница 5: ...c material check valve cartridge NBR and copper seals Lead free brass test plug 10 Spare Parts 10 1 RV260 10 2 RV260LFA Observe the local requirements regarding correct waste recycling disposal No Description Dimension Part No 1 Check valve cartridge 3 4 2110200 No Description Dimension Part No 1 Check valve cartridge 1 2 2166200 3 4 2110200 1 2164400 11 4 2164500 11 2 2164600 2 2164700 2 Plug 10 ...

Страница 6: ...ævet Med stopventiler sikres en optimal service Sørg for let tilgængelighed Forenkler vedligeholdelse og inspektion 7 2 Monteringsvejledning 1 Skyl rørledningen grundigt igennem 2 Luk stophanen på indgangssiden 3 Trykaflast udgangssiden f eks ved aftapning af vand 4 Luk stophanen på udgangssiden 5 Montér kontraventilen mellem f eks vandmåleren og trykreduktionsventilen filtret eller filterkombinat...

Страница 7: ...nger af NBR og kobber Kontrolskrue af blyfrit messing 10 Servicedele 10 1 RV260 10 2 RV260LFA De lokale forskrifter for korrekt genbrug af affald og bortskaffelse skal overholdes Nr Betegnelse Nominel bredde Bestillings nummer 1 Kontraventilindsats 3 4 2110200 Nr Betegnelse Nominel bredde Bestillings nummer 2 Kontraventilindsats 1 2 2166200 3 4 2110200 1 2164400 11 4 2164500 11 2 2164600 2 2164700...

Страница 8: ...vedlikehold Sørg for god tilgjengelighet Forenkler vedlikehold og inspeksjon 7 2 Monteringsveiledning 1 Spyl rørledningen grundig 2 Lukk stengeventilen på innløpssiden 3 Reduser trykket på utløpssiden f eks via vannkran 4 Lukk stengeventilen på utløpssiden 5 Monter tilbakeslagsventilen f eks mellom vannmåleren og reduksjonsventilen og filteret eller filterkombinas jonen Vær oppmerksom på gjennomst...

Страница 9: ...BR og kobber kontrollskrue i blyfri messing 10 Servicedeler 10 1 RV260 10 2 RV260LFA Følg de lokale reglene for forskriftsmessig gjenvinning eller eventuell kassering av avfall Nr Varenavn Nominell bredde Varenummer 1 Tilkakeslagsventil for innstikk 3 4 2110200 Nr Varenavn Nominell bredde Varenummer 2 Tilkakeslagsventil for innstikk 1 2 2166200 3 4 2110200 1 2164400 11 4 2164500 11 2 2164600 2 216...

Страница 10: ...nkel åtkomst Förenklar underhåll och inspektion 7 2 Monteringsanvisning 1 Spola igenom rörledningen väl 2 Stäng avstängningsventilen på inloppssidan 3 Tryckavlasta utloppssidan t ex genom avtappning av vatten 4 Stäng avstängningsventilen på utloppssidan 5 Montera backventilen t ex mellan vattenmätaren och tryckregulatorn filter eller en filterkombination Beakta flödets riktning Montera utan spänni...

Страница 11: ...iv plast Tätningar av NBR och koppar Kontrollskruv av blyfri mässing 10 Servicedelar 10 1 RV260 10 2 RV260LFA Följ de lokala föreskrifterna för korrekt återvinning eller bortskaffande av avfall Nr Beteckning Nom bredd Artikelnummer 1 Patronbackventil 3 4 2110200 Nr Beteckning Nom bredd Artikelnummer 2 Patronbackventil 1 2 2166200 3 4 2110200 1 2164400 11 4 2164500 11 2 2164600 2 2164700 3 Kontroll...

Страница 12: ... 49 6261 81309 http ecc emea honeywell com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl Z A La Pièce 16 1180 Rolle Switzerland by its Authorised Represen tative Honeywell GmbH MU1H 1238GE23 R1215 Subject to change 2015 Honeywell GmbH ...

Страница 13: ...MU1H 1238GE23 R1215 Honeywell GmbH 7 2 3 6 4 5 2 1 4 3 2 8 1 1 10 1 2 3 ...

Страница 14: ... 5 18 Spare Parts 5 DK 1 Sikkerhedsanvisning 6 19 Funktion 6 20 Anvendelse 6 21 Tekniske data 6 22 Varianter 6 23 Leveringsomfang 6 24 Montering 6 25 Vedligeholdelse 6 26 Bortskaffelse 7 27 Servicedele 7 N 28 Sikkerhetsinformasjon 8 29 Funksjonsbeskrivelse 8 30 Bruk 8 31 Tekniske data 8 32 Tilleggsutstyr 8 33 Leveringsomfang 8 34 Montering 8 35 Vedlikehold 8 36 Kassering 9 37 Servicedeler 9 S 1 Sä...

Отзывы: