background image

1.12  Determine your heating/cooling system type

Important! 

Heating/cooling system type must be set so that your thermostat 

operates properly and does not damage your system.
If you have a traditional system (single stage heating and cooling), your 
thermostat is set up by default to control this system. However, you will still 
need to connect your thermostat to a Z-Wave network. To do this, enter 
system setup (see step 2.1) and then proceed to 

Step  3

If you DO NOT have a single stage heating and cooling system, You MUST 
change the system type by setting system function 0170. See page 40 in the 
User Guide for a list of options. Go to 

Step  2

Not sure of your heating/cooling system type?  
Visit 

yourhome.honeywell.com or call Honeywell Customer Care toll-free at 

1-800-468-1502.

2.1  Accessing system setup

You can change options for a number 
of system functions. Available functions 
depend on the type of system you have. 
The functions, designated with four-digit 
numbers, along with their available options 
are described on pages 38–48 of the user 
guide.

2.1a 

Press 

SYSTEM

. You’ll see several 

blank buttons on the bottom of the 
display.

2.1b 

Press and hold the buttons on either 
side of the center button until the 
screen changes (approximately 5 
seconds).

Setup your thermostat

2

3.2  Share Z-Wave network

3.2a 

To share the thermostat Node 
information with additional 
Z-Wave devices, press 

s

 next 

to the function number to select 
function rf20.

3.2b  Press 

s

 next to the option 

number, and select option 

1.

3.1a  To join a Z-Wave network, 

set the Z-Wave controller to 
INCLUDE mode. 

3.1b  On the thermostat, be sure 

function 

rf10 is selected. If it is 

not selected, see 

Step  2

3.1c 

Press 

s

 next to the option 

number to select option 1 to 
add thermostat to Z-Wave 
network.

 This thermostat contains a Lithium battery which may contain Perchlorate material.
 Perchlorate Material—special handling may apply. 
 See www.dtsc.ca.gov/hazardouswaste/perchlorate

 

MERCURY NOTICE: Do not place your old thermostat in the trash if it contains  

 

 mercury in a sealed tube. Contact the Thermostat Recycling Corporation at    

 

 www.thermostat-recycle.org or 1-800-238-8192 for information on how and  

 

where to properly and safely dispose of your old thermostat.

NOTICE: To avoid possible compressor damage, do not run air conditioner  
 if the outside temperature drops below 50°F (10°C).

Need more help? 

For assistance with this product please visit yourhome.honeywell.com or call Honeywell 
Customer Care toll-free at 1-800-468-1502 before returning the thermostat to the store.

F

M32422

10

Wait

Need more help?

 Find additional 

information in the User Guide. 

Getting Help

3.1  Connect to other Z-Wave 

enabled devices

The RTH8580ZW is powered 
by Z-Wave technology so it is 
compatible with Z-Wave enabled 
devices from other manufacturers.
With a separate Z-Wave controller, 
for example, you can change your 
thermostat settings from your 
bedroom or elsewhere in the house.

Join Z-Wave network

3

2.2  Setting the date

2.2a Function 

0120 appears first by 

default. It sets the first two digits of 
the year, e.g., 

2013. Press 

st

 next 

to the option number to select the 
first two digits of the year.

2.2b 

Press 

s

 next to the function number 

to select function 0130. Function 
0130 sets the last two digits of the 
year, e.g., 20

13 

2.2c

  Press 

st

 next to the option 

number to select the last two digits 
of the year.

2.2d 

Press 

s

 next to the function number 

to select function 0140. Function 
0140 sets the month.  

2.2e

  Press 

st

 next to the option 

number to select the month.

2.2f 

Press 

s

 next to the function number 

to select function 0150. Function 
0150 sets the date.  

2.2g

  Press 

st

 next to the option 

number to select the date.

3.3  Exit system setup

When you have made all changes, 
press 

DONE

 to save and exit.

For explanation of Z-Wave 
messages, see the User Guide. 

Getting Help

DONE

0

F 10

DONE

0

F20

DONE

0

F20

2.3  Selecting a schedule format

Function 

0160 sets the schedule format. You 

can select between nonprogrammable and 
programmable. 

2.3a Press 

s

 next to the function number 

to select function 

0160. 

2.3b

  Press 

st

 next to the option number 

to change the schedule format.

0  Program schedule is off. 

Thermostat cannot be 
programmed.

4  Program schedule is on (7-day 

programmable).

2.5  Selecting system type

Function 

0170 sets your heating/cooling 

system type.  

2.5a Press 

s

 next to the function number 

to select function 

0170. 

2.5b

  Press 

st

 next to the option number 

to select your system type. 

Option 

1 (default) is a single stage heating 
and cooling system. For a list of other 
system types, see page 40 in the 
User Guide.

2.5c  Press 

s

 next to the function number 

to scroll through the remaining 
functions. For a list of functions and 
their options, see pages 

38–48 in the 

user guide.

2.5d Press 

s

 next to the four digit function 

number to scroll to function 

rf10.

Go to 

Step  3

DONE

TUE

Inside

Set To

70

0120

70

20

FAN

AUTO

DONE

CANCEL

TUE

AM

Inside

Set To

70

6:01

70

FAN

AUTO

SYSTEM

HEAT

SUN

SUN

SYSTEM

HEAT

Need more help?

 Find additional 

information in the User Guide. 

Getting Help

Function

Option

DONE

TUE

Inside

Set To

70

0130

70

12

FAN

AUTO

DONE

TUE

Inside

Set To

70

0140

70

6

FAN

AUTO

DONE

TUE

Inside

Set To

70

0150

70

15

FAN

AUTO

MCR35034

DONE

TUE

Inside

Set To

70

0160

70

0

FAN

AUTO

MCR35035

DONE

TUE

Inside

Set To

70

0170

70

1

FAN

AUTO

MCR35036

Need more help?

 Find additional 

information in the User Guide. 

Getting Help

2.4  Restore schedule defaults

2.4a Press 

s

 next to the function number 

to select function 

0165. 

2.4b

  Press 

st

 next to the option number 

to restore schedule defaults.

0  Continue using programmed 

schedule.

1  Restore thermostat program to 

energy saving settings.

DONE

TUE

Inside

Set To

70

0165

70

0

FAN

AUTO

MCR35054