Honeywell RMA 3000 Скачать руководство пользователя страница 8

 

viii 

34-ST-25-19   RMA 3000 Remote Meter Assemblies User Manual 

Release 1 

  

6/04 

 

Содержание RMA 3000

Страница 1: ..._______________________________________________________________________________________ Industrial Measurement and Control RMA 3000 Remote Meter Assemblies User Manual Doc No 34 ST 25 19 Release 1 Last Revision Date 6 04 ...

Страница 2: ...s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use While we provide application assistance personally through our literature and t...

Страница 3: ... Corporate http www honeywell com Industrial Measurement and Control http content honeywell com imc International http www honeywell com Business global asp Field Instruments http www field measurement com Technical Assistance Center ACE Honeywell com e mail Telephone Contact us by telephone at the numbers listed below Organization Phone Number United States and Canada Honeywell Inc Industrial Aut...

Страница 4: ...34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual Release 1 6 04 iv ...

Страница 5: ...ter Assembly 17 Specific Parameters of the Mode of Protection Intrinsic Safety 17 Approvals Certifications 18 Installation in Non Hazardous Locations 20 Multiple Remote Meters 20 Appendix A ATEX Directive 94 6 EC 21 DECLARATION OF CONFORMITY 27 CERTIFICATE OF MANUFACTURER 29 Appendix B Hazardous Location Wiring 31 North America 31 Cable Systems for Division 1 Zone 1 and Division 2 Zone 2 31 Append...

Страница 6: ...e 6 Factory Mutual FM Approval 37 Table 7 Canadian Standards Association CSA 38 Table 8 CENELEC LCIE Certification 41 Table 9 Standards Australia LOSC Certification 42 Table 10 Zone 2 Europe Declaration of Conformity 42 Table 11 NEMA Enclosure Type Numbers and Comparable IEC Enclosure Classification 44 Figures Figure 1 Overview of RMA Configuration 1 Figure 2 Highlights of Meter Features 2 Figure ...

Страница 7: ...g The shield must be connected to ground at only one end of the cable Connect it to the power supply and the meter sides of the wiring leave the shield insulated at the transmitter side of the wiring ATTENTION The emission limits of EN 50081 2 are designed to provide reasonable protection against harmful interference when this equipment is operated in an industrial environment Operation of this eq...

Страница 8: ...viii 34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual Release 1 6 04 ...

Страница 9: ...e meter housing that can be used in hazardous environments or in ordinary environments When used in hazardous environments the remote housing must be configured as a flameproof explosion proof housing in which all points of entrance and exit for wiring are protected and sealed via rigid metal conduit or suitable cable gland fittings Three meter styles are available and with a few exceptions any of...

Страница 10: ...ome selected cases such as operation in non hazardous locations it is possible to connect more than one meter to a given transmitter In these cases the additional meter s may be placed either at the end of a wiring run or at any location between the transmitter and other elements of the Remote Meter Assemblies configuration The number of meters that may be incorporated depends on the circuit confi...

Страница 11: ...ver the SM can be easily distinguished from the DM in that the SM has 17 segment bargraph compared to 25 for the DM more status indicators than the DM three wire connections Red Blue and Yellow to other components whereas the DM has two wire connections Red and Yellow The SM has a configuration button on the periphery of the case at lower left Electrical Characteristics The SM is a current oriente...

Страница 12: ...e transmitter provided that the sum of the current loads imposed by each DM in the loop does not exceed the capacity of the power supply ME Analog Meter Function The ME is an analog device that functions as an output indicator for any transmitter that operates in the 4 20 mA current mode Application The ME can be used as a Remote Meter Assembly component with any one of the following Smartline Tra...

Страница 13: ...encies but all are based on the fact that each meter is housed in a sealed fireproof explosion proof housing Wiring Port Seals at Remote Housing When used in hazardous environments the remote housing must be configured as a flameproof explosion proof housing in which all points of entrance and exit for wiring are protected and sealed via rigid metal conduit or suitable cable gland fittings Example...

Страница 14: ...offs in the holes and turn the meter assembly clockwise to lock it in place Ensure that the meter is oriented properly for viewing through the cap window Lubricate the threads and the o ring on the meter housing with a silicone grease such as Dow 33 or equivalent Replace the cap Figure 5 SM 3000 Meter Assembly for CE Mark Specific Parameters of the Mode of Protection Intrinsic Safety The specific ...

Страница 15: ...when it is properly installed in the flameproof explosion proof housing or when installed as intrinsically safe the meter is covered by the approvals and certifications of the housing or as intrinsically safe and of the installation practices used therewith When installed as intrinsically safe external wiring shall be in accordance with ordinary location requirements that is NEC or CEC or local co...

Страница 16: ...itters EN1I 6248 STT 3000 Series STT150 Programmable Temperature Transmitter Models STT15R STT15U STT15S Operator Manual EN1I 6190 STT 3000 Series STT250 Temperature Transmitter Models STT25H STT25D STT25M STT25T Operator Manual EN1I 6162 STT 3000 Smart Temperature Transmitter Models STT350 Operator Manual ...

Страница 17: ...ween the Power Supply Control Equipment Approved Associated Apparatus and the Transmitter or for placing the meter at the end of the wiring loop In many cases wiring methods are similar for several configurations approved by various notified bodies However notes that specify entity parameters and special conditions are unique for each approval agency and for each configuration covered by that appr...

Страница 18: ...eet 8 ME Analog Meter Sheet 9 RMA 3000 DM 51204241 For intrinsically safe application CSA Lightning Protection Option Sheet 1 Intrinsically Safe CSA Sheet 2 RMA 3000 SM Sheet 3 RMA 3000 ME Sheet 4 ME Analog Meter Sheet 5 RMA 3000 DM Non Lightning Protection Option Sheet 6 RMA 3000 SM Sheet 7 RMA 3000 ME Sheet 8 ME Analog Meter Sheet 9 RMA 3000 DM 51204242 ST 3000 Release 300 Series 100 and 900 Tra...

Страница 19: ...ntrinsically safe application CENELEC 51450805 ST 3000 HART Series 100 and 900 Transmitters Note these drawings are also included in 34 ST 25 17A Release 300 with HART Communications Option User Manual For intrinsically safe application CSA Lightning Protection Option Sheet 1 Intrinsically Safe CSA Sheet 2 Communicator Sheet 3 ME Analog Meter Sheet 4 RMA 3000 SM Sheet 5 RMA 3000 SM Sheet 6 RMA 300...

Страница 20: ...ing drawings to indicate the similarities differences among various wiring configurations WARNING These simplified drawings are not intended as a substitute for the certified drawings The certified drawings must be used as the sole source for wiring installation instructions A legend for use with the wiring diagrams overview is given in Figure 8 In this illustration the power source shown at left ...

Страница 21: ...ng Overview SM ST 3000 Transmitter without HART Option SM for Release 300 Transmitter without HART Option With Lightning Protection Option Drawings 51204241 2 FM 51204242 2 CSA 51204243 2 CENELEC Without Lightning Protection Option Drawings 51204241 6 FM 51204242 6 CSA 51204243 5 CENELEC ...

Страница 22: ... Manual Release 1 6 04 Table 3 Wiring Overview SM ST 3000 Transmitter with HART Option SM with HART Option With Lightning Protection Option Drawings 51205784 3 FM 51450806 4 5 CSA Without Lightning Protection Option Drawings 51205784 6 FM 51450806 9 CSA ...

Страница 23: ...out HART Option ME With Lightning Protection Option Drawings 51204241 3 FM 51204242 3 CSA 51204243 3 CENELEC 51205784 4 FM HART 51450805 6 7 CSA HART Without Lightning Protection Option Drawings 51204241 7 FM 51204242 7 CSA 51204243 6 CENELEC 51205784 7 FM HART 51450806 10 11 CSA HART Note This configuration is approved only for HART ...

Страница 24: ...r Manual Release 1 6 04 Table 5 Wiring Overview DM ST 3000 Not Approved for HART DM Release 300 Transmitter With Lightning Protection Option Drawings 51204241 5 FM 51204242 5 CSA Without Lightning Protection Option Drawings 51204241 9 FM 51204242 9 CSA ...

Страница 25: ...tand offs in the holes and turn the meter assembly clockwise to lock it in place Ensure that the meter is oriented properly for viewing through the cap window Lubricate the threads and the o ring on the meter housing with silicon grease such as Dow Corning 33 Replace the cap Figure 9 SM 3000 Meter Assembly for CE Mark Specific Parameters of the Mode of Protection Intrinsic Safety The specific para...

Страница 26: ... when it is properly installed in the flameproof explosion proof housing or when installed as intrinsically safe the meter is covered by the approvals and certifications of the housing or as intrinsically safe and of the installation practices used therewith When installed as intrinsically safe external wiring shall be in accordance with ordinary location requirements that is NEC or CEC or local c...

Страница 27: ...mitters EN1I 6248 STT 3000 Series STT150 Programmable Temperature Transmitter Models STT15R STT15U STT15S Operator Manual EN1I 6190 STT 3000 Series STT250 Temperature Transmitter Models STT25H STT25D STT25M STT25T Operator Manual EN1I 6162 STT 3000 Smart Temperature Transmitter Models STT350 Operator Manual ...

Страница 28: ...l the SM and the ME are current oriented series connected devices Multiple meters any combination of SM and ME may be connected to a given transmitter provided that the following condition is met Voltage Pwr Supply Minimum Terminal Voltage Transmitter Number of SMs 2 3 volts Resistance Total Loop 22 mA NOTE Total loop resistance must include wiring and cabling as well as for associated apparatus s...

Страница 29: ...ther change and refinement whose details are beyond the scope of this Appendix Further information can be obtained in the Official Journal of the European Communities No L100 1 and in related publications such as Guidelines on the Application of Directive 94 9 EC Both of these items are available at http europa eu int comm enterprise atex index htm Products that have been previously certified unde...

Страница 30: ...Before installing the equipment in a potentially explosive atmosphere please read the information provided in this Manual which supports the ATEX certifications for this product CE Conformity The Honeywell RMA 3000 Models RMA300 DM SM ME Remote Meter Assemblies are in conformity with the protection requirements of the following European Council Directives 94 9 EC the Explosive Atmospheres ATEX Dir...

Страница 31: ...plete model number See the Model Selection Guide 34 ST 16 46 The serial number is 10 digits long The first digit is the STT Type R U or S The second digit is the year code 0 9 The third and fourth digits are the week code in hexadecimal The remaining six digits are the serial number Apparatus Marked with Multiple Types of Protection The user must determine the type of protection required for insta...

Страница 32: ...ed on the enclosure The following is a representation of this nameplate Nameplate 51452470 001 nA Zone 2 is mounted on the enclosure The following is a representation of this nameplate Nameplate 50003896 001 multiple certification is mounted on the enclosure The following is a representation of this nameplate ...

Страница 33: ...er supply to field wiring terminals and Ucc 42 V Output Signal 4 20 mA Special conditions for safe use Flameproof Installation Ambient operating temperature 20 to 65ºC Specific Parameters for Non Sparking Zone 2 Installation Honeywell certified Supply Voltage Supply Current Ambient Temperate Limits Temperature Classification 11 42 Vdc 23 mA 20o C to 65 o C T6 at Ta 65o C Special Conditions for Saf...

Страница 34: ...26 34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual Release 1 6 04 ...

Страница 35: ...Apparatus for Potentially Explosive Atmospheres Flameproof Enclosure d EN 50020 1994 Electrical Apparatus for Potentially Explosive Atmospheres Intrinsic Safety i EN 50284 1999 Special Requirements for Construction Test and Marking of Electrical Apparatus of Equipment Group II Category 1 G EC Type Examination Certificates Production Quality Assurance Notification Notified Bodies LCIE Groupe Bureau...

Страница 36: ...28 34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual Release 1 6 04 ...

Страница 37: ...zardous areas must comply with VDE specification 0165 IEC 60079 14 EN 50021 and or valid national standards for installation and operation 2 Before commissioning of this equipment it must be verified that the power supply voltage cannot exceed the 42 Vdc maximum for 4 20 mA analog DE and Smart meters 3 The electronic assemblies in these units are non repairable items and if faulty must be replaced...

Страница 38: ...30 34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual Release 1 6 04 ...

Страница 39: ...lands approved for the location shall be used Class I Division 2 and Group II Zone 2 Requirements NEC Fixed wiring methods for Class I Division 2 locations specifies threaded rigid metal conduit threaded steel intermediate metal conduit type MI mineral insulated type MC metal clad type ITC intermediate tray cable or type TC tray cable listed for use in Class I Division 2 locations with cable with ...

Страница 40: ... entry device and a particular type of cable in compliance with EN 50018 b Thermoplastic thermosetting or elastomeric cable that is substantially compact and circular has extruded bedding and the fillers if any are non hygroscopic may utilize flameproof cable entry devices incorporating a compression seal c Mineral insulated cable with or without plastic outer covering with appropriate flameproof ...

Страница 41: ... quantities sufficient to produce explosive or ignitable mixtures II Presence of combustible dusts powders or grains III Presence of easily ignitable fibers or flyings Divisions The classes listed above are further classified into one of the following divisions based upon the level of risk present Division Description of Risk 1 Locations in which hazardous concentrations of flammable gases or vapo...

Страница 42: ...ene or gasses or vapors of equivalent hazard D Atmospheres such as acetone ammonia benzene butane cyclopropane ethanol gasoline hexane methanol methane natural gas naphtha propane or gases or vapors of equivalent hazard Class II Group Description E Atmospheres containing combustible metal dusts including aluminum magnesium and their commercial alloys and other metals of similarly hazardous charact...

Страница 43: ...conditions Temperature Classification Equipment intended for installation directly within the hazardous location classification must also be classified for the maximum surface temperature that can be generated under normal or fault conditions as referenced to either 40 C 104 F or the maximum operating ambient of the equipment whichever is greater The maximum surface temperature must be less than t...

Страница 44: ...output voltage which can be delivered to the hazardous classified location This voltage is the maximum from a single channel Isc Maximum output current which can be delivered to the hazardous classified location This current is the maximum from a single channel Vt Maximum output voltage which can be delivered to the hazardous classified location This voltage is the maximum across any combination o...

Страница 45: ... may be connected and remain intrinsically safe Both FMRC and CSA d entity parameters are defined in Tables 6 and 7 Table 6 Factory Mutual FM Approval Code Description 1C Explosion proof for Class I Division 1 Groups A B C D Dust Ignition proof for Class II Division 1 Groups E F G Suitable for Class III Division 1 Conduit seals required within 18 of enclosure Group A only Intrinsically Safe for us...

Страница 46: ...red 42 Vdc max Intrinsically Safe for Class I Groups A B C D Class II Groups E F G Class III Divisions 1 T4 at 40 C T3A at 93 C maximum ambient Install per Honeywell drawing 51204242 Suitable for Class I II III Division 2 Groups A B C D E F G hazardous locations T4 at 93 C 42 Vdc max Environmental Indoor and outdoor hazardous locations Encl 4X CSA Certified Barriers 1 Class I II III Division 1 and...

Страница 47: ...s Location 0 Explosive gas atmosphere is present continuously or is present for long periods 1 Explosive gas atmosphere is likely to occur in normal operation 2 Explosive gas atmosphere is not likely to occur in normal operation and if it does occur it will exist for a short period only IEC Groups Flammable gases vapors and mists are further classified into groups according to the energy required ...

Страница 48: ... energy of sparks under 1 fault Pressurized p Zone 1 Keeps flammable gases out Encapsulation m Zone 1 2 Keeps flammable gases out Increased Safety e Zone 1 2 No arcs sparks or hot surface Powder Filled q Zone 1 2 Contains explosion and quenches flame Oil Immersion o Zone 1 2 Keeps flammable gases out Non sparking nA Zone 2 No arcs sparks or hot surfaces under normal conditions Enclosed Break nC Zo...

Страница 49: ...temperature shall be indicated in identification numbers as listed in the following table Maximum Temperature Degrees C Degrees F Identification Number 450 842 T1 300 572 T2 200 392 T3 135 275 T4 100 212 T5 85 185 T6 Certification and Conformity Details Table 8 CENELEC LCIE Certification Code Description 3D Flameproof Supply 45 Vdc IP 66 67EEx d IIC T6 3A Intrinsically Safe EEx ia IIC T5 40 Ta 93 ...

Страница 50: ...arameters 1 Ui 42 4 V Ii 225 mA Pi 1 2 W Ci 4 2 nF Li 0 With no integral indicator or with integral Smart Meter option SM Li 150 µH With Analog Meter option ME 1 Install in accordance with Honeywell drawing 51204309 Table 10 Zone 2 Europe Declaration of Conformity Code Description 3N Electrical Apparatus With Type of Protection n per IEC 79 15 IP 66 67 Ex II 3 GD T 1 X Council Directive 94 9 EC 40...

Страница 51: ...pecify degrees of protection against mechanical damage of equipment risk of explosion or conditions such as moisture produced for example by condensation corrosive vapors fungus or vermin NEMA Standards NEMA Standards Publication 250 Enclosures for Electrical Equipment 1000 Volts Maximum does test for environmental conditions such as corrosion rust icing oil and coolants For this reason and becaus...

Страница 52: ...st requirements for the associated IEC classifications for this reason the Table cannot be used to convert from IEC classifications to NEMA types Table 11 NEMA Enclosure Type Numbers and Comparable IEC Enclosure Classification NEMA Enclosure Type Number IEC Enclosure Classification Designation 1 IP 10 2 IP 11 3 IP 54 3R IP 14 3S IP 54 4 and 4X IP 56 5 IP 52 6 and 6P IP 67 12 and 12K IP 52 13 IP 54...

Страница 53: ...Release 1 34 ST 25 19 RMA 3000 Remote Meter Assemblies User Manual 45 6 04 ...

Страница 54: ...Industrial Measurement and Control Honeywell International Inc 2500 West Union Hills Drive Phoenix AZ 85027 ...