Honeywell RAE Systems BioHarness 3 Скачать руководство пользователя страница 4

 

 

 

 

BioHarness 3 

 

 

QUICK REFERENCE 

 

 

By Honeywell 

2.

 

Click “Save As” and give a name to the new alarm template. 

 

Typically, the name of the person who will wear BioHarness 3 (“Test,” in this case). 

 

           

 

 

3.

 

Input the alarm levels for the individual, click “Save,” and close the dialog box. 

4.

 

Within the Device Pane of ProRAE Guardian, right-click on the BioHarness 3 unit that you want 
to assign alarms to, and then select “Properties.” 

 

             

 

 

5.

 

Choose the saved alarm template from the drop-down menu and then click “Apply.” 

 

              

 

 

6.

 

To remove alarm levels from a BioHarness 3, choose “Remove Binding” and then click “Apply.” 

 

             

 

 

BioHarness 3 Strap Care 

The strap can be hand-washed or machine laundered, following these steps: 

 

1.

 

Detach the BioHarness Echo Module. 

2.

 

Hand wash using a mild soap or detergent or machine wash: 

 

Cool temperature (40° C/104° F maximum) 

 

Delicate setting 

 

Wash pouch recommended 

 

Spin dry or hang to dry out of direct sunlight 

 

IMPORTANT! Do not use bleach or disinfectant. Do not tumble dry. Do not iron. Do not dry-clean. 

 

Содержание RAE Systems BioHarness 3

Страница 1: ...w Activity 0 8 Walking Jogging 0 8 Running Posture Degrees 0 to 180 0 Vertical 90 Horizontal 180 Inverted Temperature Degrees F or C 50 to 140 F 10 to 60 C Operation 1 Moisten the gray sensor pads on the back of the strap with water 2 Snap the BioHarness Echo Module onto the BioHarness 3 by clicking the bottomin first andthen the top 3 Power on the BioHarness Echo Module by pressing the button in ...

Страница 2: ...is typically reached in 1 hour While charging the BioHarness Echo Module s orange LED flashes When fully charged the orange LED glows continuously 3 Once it is charged remove the BioHarness Echo Module from the Charging Cradle Pairing The BioHarness Echo Module And The RAELink3 Via Bluetooth After an initial pairing of the BioHarness Echo Module with the RAELink3 the two will automatically find ea...

Страница 3: ...eless units within the ProRAE Guardian software If the Unit ID has not been set to a unique identification number you must set it 1 Enter Programming Mode on the RAELink3 by holding the N and MODE keys together 2 Press N until you can set the UNIT ID 3 Select a number between 01 and 64 4 Press and hold MODE for two seconds and save it Defining Alarm Levels Important Alarm limits should only be set...

Страница 4: ...lect Properties 5 Choose the saved alarm template from the drop down menu and then click Apply 6 To remove alarm levels from a BioHarness 3 choose Remove Binding and then click Apply BioHarness 3 Strap Care The strap can be hand washed or machine laundered following these steps 1 Detach the BioHarness Echo Module 2 Hand wash using a mild soap or detergent or machine wash Cool temperature 40 C 104 ...

Страница 5: ...device is not being worn Flash Heart rate locked Solid Error Green Solid Logging error Flash Logging Off Not logging LED State In Cradle Orange Off No power or not fully in cradle Solid Charged Flash Charging Blue Off Should be off at all times Red Should be off at all times Green Solid Logging error Off No logs finished downloading Flash Downloading RAELink3 Remote not communicating with ProRAE G...

Отзывы: