background image

R7515C MacroCel™ CONTROLLER 

SIX NO. 10 X 1/2-INCH 

Wire Subpanel to Interface Board 

NOTES: 

1.  All wiring must conform to local codes, 

ordinances, and regulations. Refer to job 
drawings for details. 

2.  Use copper conductors only. 
3.   For 220/240V ac 50/60 Hz installations, verify 

that voltage difference between any conductor 
and earth ground does not exceed 150V ac. 

4.   An End-of-Line Resistor (EOLR) for use with the 

C-NAP bus wiring is integral to the MacroCel 
Subpanel Interface Board. 

CAUTION 

Verify that ac power is 

not connected to MacroCel 

power wiring terminal block (H-N-G) until system is 
checked by a Honeywell Representative. 

Wire the Subpanel as follows: 

1.   Connect field wiring to MacroCel subpanel Interface 

Board or accessory devices per job drawings. Figure 3 
shows MacroCel interface board terminal arrangement. 
Figure 4 shows typical wiring. 

Fig. 2. Mounting MacroCel subpanel in full-sized 

ring cabinet. 

FULL-SIZE 
CABINET

MOUNTING SCREWS 

C5690 

MacroCel 
SUBPANEL 

LOWER OUTER KNOCKOUTS (4) 
RECOMMENDED FOR EASE 
OF INSTALLATION 

10 

11 

12 

13 

14 

R1 

RTD 

D1 

DIG 

+10 

+10 

V1 

VOLT 

R2 

RTD 

D2 

DIG 

V2 

VOLT 

TB1 

R1 

R2 

TERM V1 

TERM V2 

15 

16 

17 

18 

19 

20 

21 

22 

23 

24 

25 

26 

27 

28 

R3 

RTD 

D3 

DIG 

+10 

+10 

V3 

VOLT 

R4 

RTD 

D4 

DIG 

V4 

VOLT 

TB2 

R3 

R4 

TERM V3 

TERM V4 

29 

30 

31 

32 

33 

34 

35 

36 

37 

38 

39 

40 

41 

42 

R5 

RTD 

D5 

DIG 

+10 

+10 

V5 

VOLT 

R6 

RTD 

D6 

DIG 

V6 

VOLT 

TB3 

R5 

R6 

TERM V5 

TERM V6 

R7 

RTD 

D7

DIG 

+10 

+10 

V7 

VOLT 

R8 

RTD 

D8 

DIG 

V8 

VOLT 

TB4 

47 

48 

49 

50 

51 

52 

53 

54 

55 

56 

43 

45 

46 

44 

J1 

J2 

J3 

J4 

R7 

R8 

TERM V7 

TERM V8 

24 VDC 

TB10 

C1 

TO-1 

TB5 

65 

66 

67 

68 

69 

70 

71 

72 

61 

63 

64 

62

COM1-2 

TO-2 

TO-3 

COM3-4 

TO-4 

T1 

T2 

T1 

T2 
T1 

T2 









POWER 

LED 

F1 
2A 

CR2 

TB8 

POWER 

24VAC T1

24VAC T2 

J5 

CNAP 
BUS 
JACK 

ON 

OFF 

S1 

EOL 

J6 

J7 



1&2 
2&3 

J8 

CNAP 

OUT 

IN 

TB9 

IN 
OUT 

AO—1 

TB6 

77 

78

RET

ANALOG 

79 

80 

AO—2 

RET 

AO—3 

TB7 

89 

90

RET 

ANALOG 

91 

92 

AO—4 

RET 

MacroCel 
CARD CAGE 

JB1 

INPUTS 

WALL MOD 

CONNECTOR J8 

0. 16A MAX 

CNAP 
BUS 

0.16A MAX 

83 

84 

85 

86 

87 

88 

K1 

K2 

OUTPUTS 

95 

96 

97 

98 

99 

100 

K3 

K4 

SUBPANEL 
SUPPORT (2) 

81 

82 

AO—5 

RET 

93 

94 

AO—4 

RET 

MacroCel 
INTERFACE 
BOARD 

MOUNTING 

TAB (2) 

C5611 

Fig. 3. MacroCel interface board terminal arrangement. 

95-7456—1  

Содержание R7515C MacroCel

Страница 1: ...ler MacroCel Card Cage Assembly Assembly from carton Check Assembly and report any damage to a Honeywell representative 3 Before installing verify that Ring Cabinet is installed per job drawings Refer to General Purpose Cabinet Installation Instructions 95 7438 for details 4 Installation requires No 10 x 1 2 in sheet metal screws not supplied Six screws are required for full sized subpanel four fo...

Страница 2: ...ASE OF INSTALLATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R1 RTD D1 DIG 10 10 V1 VOLT R2 RTD D2 DIG V2 VOLT TB1 R1 R2 TERM V1 TERM V2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 R3 RTD D3 DIG 10 10 V3 VOLT R4 RTD D4 DIG V4 VOLT TB2 R3 R4 TERM V3 TERM V4 29 30 31 32 33 34 35 36 37 38 39 40 41 42 R5 RTD D5 DIG 10 10 V5 VOLT R6 RTD D6 DIG V6 VOLT TB3 R5 R6 TERM V5 TERM V6 R7 RTD D7 DIG 10 10 V7 VOLT R8 RTD ...

Страница 3: ... 49 50 51 52 53 54 55 56 43 45 46 44 J1 J2 J3 J4 R7 R8 TERM V7 TERM V8 5 7 5 8 5 9 6 0 24 VDC TB10 C1 TO 1 TB5 65 66 67 68 69 70 71 72 61 63 64 62 COM1 2 TO 2 TO 3 COM3 4 TO 4 T1 T2 T1 T2 T1 T2 O U T P U T T R I A C 2 4 V A C POWER LED F1 2A CR2 TB8 POWER 24VAC T1 24VAC T2 J5 CNAP BUS JACK ON OFF S1 A EOL J6 J7 1 2 3 1 2 2 3 J8 3 7 4 5 CNAP OUT IN 7 6 TB9 IN OUT AO 1 TB6 77 78 RET ANALOG 79 80 AO ...

Страница 4: ...mounting surface of Assembly flat against Subpanel aligning sides of Assembly with sides of mounting silhouette and top of Assembly approximately 1 in 25 mm above top of mounting silhouette 2 Slide Assembly down simultaneously engaging lower supports and preinstalled mounting tab screws 3 Tighten screws to secure Assembly to Subpanel 4 Connect input output board ribbon cables and power cable to In...

Отзывы: