2 ZONE T6R SMART THERMOSTAT 

 

 

 

  

T6R-2Z-EN0H 8603 NL01 R0718 

 

Special Features

 

Description

 

Heat Range 

The normal lower temperature limit of 5

 o

C can be increased up to 21

 o

C to protect the 

inhabitants from cold conditions. This is a useful feature aimed at supporting the elderly, 

children and disabled inhabitants. 

The normal upper temperature limit of 35

 o

C can be reduced down to 21

 o

C to save energy. This 

feature is useful for leased homes and apartments. 

Schedule options 

The thermostat has 2 default schedules: daily (every day) and 5+2 (week + weekend days) 

Optimisation (optimal 

start, optimal stop and 

delayed start) 

Optimal Start: learns how long it takes your system to reach the programmed temperature. It 

turns on the heating system earlier to make sure it’s comfortable at the scheduled time.

 

Optimal Stop: Saves energy and money by switching off a little bit earlier than the normal 

programmed time. If the home is up to temperature, it will not notice the effect on the 

temperature, but will show a difference in the fuel bill.  

Delayed start: Saves energy by slightly delaying the start of heating depending on the 

difference between the scheduled temperature and the actual room temperature 

Clock setting 

Change display format (default 24hr) and adjust time and date. 

When connected to Internet time and date will be synchronized 

Low Load Control 

If the Receiver box is connected to an OpenTherm appliance this setting is used in the demand 

control. When an appliance is no longer able to modulate lower the control switches from 

modulating control to low/off control. 

Temperature Offset 

If the Thermostat is located in a hot/cold location and cannot be moved because of wiring then 

the measured/ displayed temperature can be adjusted by +/- 1,5

 o

C. This feature is useful if the 

homeowner wants the reading to match another appliance temperature display. 

Binding 

Menu to bind the Thermostat and the Receiver box, test the RF signal strength of the radio 

communication and to clear an existing binding. 

Reset 

Menu to reset the thermostat back to factory default settings, reset the schedule to default 

settings, reset the Wi-Fi and Homekit settings. 

Failsafe  

When the radio communication between the Thermostat and Receiver box is lost for longer 

than 1 hour the Receiver box will start to cycle the demand 20% on / 80% off. 

 
 
 

Menu item 

Default 

Options 

Language 

English 

English, Francais, Espanol, Deutsch, Nederlands, Italiano 

OpenTherm 

OpenTherm boiler data when a vailable (see OpenTherm communication) 

Cycle rate 

3,6,9 or 12 

Min on time 

1 minute 

1, 2, 3, 4 or 5 minutes 

Heat range 

Min = 5.0 

Max = 37.0 

Min: 5.0°C to 21.0 °C, Max:21.0°C to 37.0 °C 

Schedule options 

Daily 

1 = daily schedule, 2 = 5+2 days schedule 

Optimisation 

Opt.start on 

Opt.stop off 

Opt start: 0 = off, 1 = on, 2 = Delayed start 

Opt stop: 0 = off, 1 = on 

Clock 

Format: 24h 

Time: --:-- 

Date: 01/09/2016 

Clock format: 1 = 12h, 2 = 24h 

Setup time and date 

Low Load Control 

ON 

0= Off, 1 = On 

Temperature offset  0.0 

-1.5°C to 1.5 °C 

Bind 

Bind, check RF and clear bind. 

Adv Reset 

Factory, schedule, Wi-Fi and Homekit reset 

Failsafe 

OFF 

0= Off, 1 = On 

 

ADVANCED MENU 

To enter the Advanced menu (installer set-up):

 

 

 

Press the 

menu key for 5 seconds. 

Содержание R6H911RF

Страница 1: ...to connect to the Internet Smart Home and Apple HomeKit ready A dynamic text display on the LCD that gives enhanced feedback to the user installer High LCD Contrast and backlighting for easier viewing in all light conditions Time out screen with selectable brightness Factory programmed daily or 5 2 default heating schedule Schedule with up to 6 independent time and temperature pairs to suit the co...

Страница 2: ...2 ZONE T6R SMART THERMOSTAT 2 T6R 2Z EN0H 8603 NL01 R0718 T6R THERMOSTAT DISPLAY BUTTON LAYOUT Reference to the icons 2 CHANNEL RECEIVER BOX INTERFACE Schedule period ...

Страница 3: ...te cable is required C Wiring 2 zone valves 24V and 24V on off boiler Zone valve end switches used for controlling boiler demand D Wiring 2 zone valves 24V OpenTherm boiler Demand of zones used for controlling modulating OpenTherm boiler A Wiring 2 zone valves 230V and basic 230V on off boiler Zone valve end switches used for controlling boiler demand B Wiring 2 zone valves 230V and OpenTherm boil...

Страница 4: ...ew and hinge open to remove the top cover To ensure your safety always make sure mains power is switched OFF before accessing wiring Find a suitable location near the boiler Leave at least 30cm distance from any metal objects including wall boxes and boiler housing POWER UP 2 CHANNEL RECEIVER BOX Turn ON mains power to the 2 channel Receiver box and the Heating Appliance and installation is comple...

Страница 5: ...t binding with 2 channel Receiver box Next put the 2 channel Receiver box into binding mode by pressing Zone 1 button for 3 sec The first RF LED will flash amber Touch and the signal will be sent When binding successful thermostat shows SUCCESSS Zone 1 status LED shows green touch to proceed Touch to select system type When binding is NOT successful Thermostat will show FAILED Receiver box will ex...

Страница 6: ...zone thermostat near the 2 channel Receiver box and plug in the adapter When SETUP is displayed on the screen of the thermostat follow the next steps Touch to begin setup Select language Set clock format time and date Touch to start binding with 2 channel Receiver box Next put the 2 channel Receiver box into binding mode by pressing Zone 2 button for 3 sec The first RF LED will flash amber Touch a...

Страница 7: ... near draughts in direct sunlight or near heat sources It should be at least 1 2 1 5 meters from the floor Use the included stickers on the cover of the Receiver box to indicate the application Touch to finalise setup to setup using the Honeywell App is currently unsupported Touch to select heat only application Zone 2 thermostat setup and binding is complete Thermostat is switched OFF Once setup ...

Страница 8: ...is no longer able to modulate lower the control switches from modulating control to low off control Temperature Offset If the Thermostat is located in a hot cold location and cannot be moved because of wiring then the measured displayed temperature can be adjusted by 1 5 oC This feature is useful if the homeowner wants the reading to match another appliance temperature display Binding Menu to bind...

Страница 9: ... have a small internal storage for hot tap water By keeping a number of liters of hot water the appliance can supply hot tap water directly without having to heat it up first With a longer period of none use or absence for example sleep or holiday the hot water storage does not have to be kept at a high temperature The T6 T6R thermostat can provide additional savings here With the last programmed ...

Страница 10: ...ill be switched on when one of the zone valves is completely opened and the end switch switches When both end switches are not switched the boiler is off The cycle rate setting determines also the cycle rate of the boiler There is no synchronization of the heat demand of the 2 zone thermostats which could cause the boiler to switch off end demand of a zone and almost instantly switch on again by t...

Страница 11: ...lectable by application see installer set up Wiring Terminal block capable of accepting wires up to 1 5 mm2 Wire access From back via large wall box opening From bottom with cable clamps Mains wiring left Low voltage wiring right Dimensions 110 x 110 x 40 mm w x h x d IP class 30 RF communication RF operation band ISM 868 0 868 6 MHz 1 duty cycle Max power 25mW Protocol Encrypted Comm Range 30 m i...

Страница 12: ... thermostat NO COMMUNICATION RECEIVER BOX The thermostat receives no communication from the thermostat RF signal is blocked due to the location of the thermostat Receiver box is no longer powered RF communication might be too far or is blocked due to the location of the Thermostat or Receiver box Check the power to the Receiver box RF SIGNAL OFRECEIVER BOX LOW There is a weak radio signal from the...

Отзывы: