background image

2 ZONE T6R SMART THERMOSTAT 

 

 

 

  

T6R-2Z-EN0H 8603 NL01 R0718 

11 

DIMENSIONS 

 

T6R 

RECEIVER BOX 

SPECIFICATIONS 

T6R Thermostat 

Control form 

 

Adaptive Fuzzy Logic 

Room 

Temperature 

display range 

 

From 0

 o

C to 50

 o

Dimensions 

(w x h x d) 

 

T6R (wireless) 108 x 103 x 68 mm 

 

 

Time display 

 

24 hour or 12 hour AM/PM format 

Time keeping 

accuracy 

 

Synchronized with Internet when 

connected or typically better than 10 

minutes per year  

Program  

 

5+2 or daily schedule with 6 daily time 

and temperature level changes 

Time setting 

resolution 

 

 

Program - 10 minute steps 

Temperature 

setting range 

 

Program  : 5 to 37

o

C in 0.5 

o

C steps  

 

OFF  

: 5

 o

 

Power 

 

T6R (wireless) 5VDC power adapter 

 

Receiver box 

Power 

 

230VAC 

Electrical rating 

Relay contacts 

 

230 V~, 50...60 Hz, 0.5 A to 5 A resistive  

0.5 A to 3 A inductive (0.6 pf)  

24 V~, 50...60 Hz, 0.5 A to 5 A resistive 

0.5 A to 3 A inductive (0.6 pf)  

 

Cycle rate 

 

Selectable by application (see installer 

set up) 

Wiring 

 

Terminal block capable of accepting 

wires up to 1.5 mm

2

 

Wire access 

 

From back via large wall box opening. 

From bottom with cable clamps. 

Mains wiring 

 left. 

Low voltage wiring 

 right. 

Dimensions 

 

110 x 110 x 40 mm (w x h x d) 

 

IP class 

 

30 

 

RF communication 

RF operation 

band 

 

ISM (868.0-868.6) MHz, 1% duty cycle 

Max. power 

 

25mW 

 

 

 

Protocol 

 

Encrypted  

 

 

Comm. Range 

 

30 m in a residential building 

environment 

Comm.  

technology 

 

short, high rate transmissions to 

minimise air time and avoid collisions 

 

 

Receiver class 

R.E.D. 

 

Receiver Category 2 

 

 

RF binding 

method 

 

Factory pre-bound packs 

 

 

 

Wi-Fi 

 

IEEE 802.11b/g/n 

 2.4GHz 

Max. power 

 

100mW 

 

 

 

Environmental and standards 

Operating 

temperature range 

 

0 to 40

o

C  

 

 

Shipping and storage 

temperature 

 

-20 to 55

o

Humidity range 

 

10 to 90% rh, non-condensing 

 

 

EMC 

 

2014/30/EU 

LVD 

 

2014/35/EU 

R.E.D. 

 

2014/53/EU 

WEEE Directive 

 

2012/19/EU 

 

 

 

ErP 

 

Class VI (+4%), (EU) 811/2013 

 

Honeywell, declares that this thermostat is in compliance 

with the essential requirements and other relevant 

provisions of Directive 2014/53/EU 

 

Содержание R6H911RF

Страница 1: ...to connect to the Internet Smart Home and Apple HomeKit ready A dynamic text display on the LCD that gives enhanced feedback to the user installer High LCD Contrast and backlighting for easier viewing in all light conditions Time out screen with selectable brightness Factory programmed daily or 5 2 default heating schedule Schedule with up to 6 independent time and temperature pairs to suit the co...

Страница 2: ...2 ZONE T6R SMART THERMOSTAT 2 T6R 2Z EN0H 8603 NL01 R0718 T6R THERMOSTAT DISPLAY BUTTON LAYOUT Reference to the icons 2 CHANNEL RECEIVER BOX INTERFACE Schedule period ...

Страница 3: ...te cable is required C Wiring 2 zone valves 24V and 24V on off boiler Zone valve end switches used for controlling boiler demand D Wiring 2 zone valves 24V OpenTherm boiler Demand of zones used for controlling modulating OpenTherm boiler A Wiring 2 zone valves 230V and basic 230V on off boiler Zone valve end switches used for controlling boiler demand B Wiring 2 zone valves 230V and OpenTherm boil...

Страница 4: ...ew and hinge open to remove the top cover To ensure your safety always make sure mains power is switched OFF before accessing wiring Find a suitable location near the boiler Leave at least 30cm distance from any metal objects including wall boxes and boiler housing POWER UP 2 CHANNEL RECEIVER BOX Turn ON mains power to the 2 channel Receiver box and the Heating Appliance and installation is comple...

Страница 5: ...t binding with 2 channel Receiver box Next put the 2 channel Receiver box into binding mode by pressing Zone 1 button for 3 sec The first RF LED will flash amber Touch and the signal will be sent When binding successful thermostat shows SUCCESSS Zone 1 status LED shows green touch to proceed Touch to select system type When binding is NOT successful Thermostat will show FAILED Receiver box will ex...

Страница 6: ...zone thermostat near the 2 channel Receiver box and plug in the adapter When SETUP is displayed on the screen of the thermostat follow the next steps Touch to begin setup Select language Set clock format time and date Touch to start binding with 2 channel Receiver box Next put the 2 channel Receiver box into binding mode by pressing Zone 2 button for 3 sec The first RF LED will flash amber Touch a...

Страница 7: ... near draughts in direct sunlight or near heat sources It should be at least 1 2 1 5 meters from the floor Use the included stickers on the cover of the Receiver box to indicate the application Touch to finalise setup to setup using the Honeywell App is currently unsupported Touch to select heat only application Zone 2 thermostat setup and binding is complete Thermostat is switched OFF Once setup ...

Страница 8: ...is no longer able to modulate lower the control switches from modulating control to low off control Temperature Offset If the Thermostat is located in a hot cold location and cannot be moved because of wiring then the measured displayed temperature can be adjusted by 1 5 oC This feature is useful if the homeowner wants the reading to match another appliance temperature display Binding Menu to bind...

Страница 9: ... have a small internal storage for hot tap water By keeping a number of liters of hot water the appliance can supply hot tap water directly without having to heat it up first With a longer period of none use or absence for example sleep or holiday the hot water storage does not have to be kept at a high temperature The T6 T6R thermostat can provide additional savings here With the last programmed ...

Страница 10: ...ill be switched on when one of the zone valves is completely opened and the end switch switches When both end switches are not switched the boiler is off The cycle rate setting determines also the cycle rate of the boiler There is no synchronization of the heat demand of the 2 zone thermostats which could cause the boiler to switch off end demand of a zone and almost instantly switch on again by t...

Страница 11: ...lectable by application see installer set up Wiring Terminal block capable of accepting wires up to 1 5 mm2 Wire access From back via large wall box opening From bottom with cable clamps Mains wiring left Low voltage wiring right Dimensions 110 x 110 x 40 mm w x h x d IP class 30 RF communication RF operation band ISM 868 0 868 6 MHz 1 duty cycle Max power 25mW Protocol Encrypted Comm Range 30 m i...

Страница 12: ... thermostat NO COMMUNICATION RECEIVER BOX The thermostat receives no communication from the thermostat RF signal is blocked due to the location of the thermostat Receiver box is no longer powered RF communication might be too far or is blocked due to the location of the Thermostat or Receiver box Check the power to the Receiver box RF SIGNAL OFRECEIVER BOX LOW There is a weak radio signal from the...

Отзывы: