background image

Honeywell Safety and Productivity Solutions 

9680 Old Bailes Road
Fort Mill, SC 29707 
www.honeywell.com

32313758-B-EN  |  10/16
© 2016 Honeywell International Inc.

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of 
defective materials and faulty workmanship during the applicable 
warranty period. Honeywell’s standard product warranty applies 
unless agreed to otherwise by Honeywell in writing; please refer 
to your order acknowledgement or consult your local sales office 
for specific warranty details. If warranted goods are returned to 
Honeywell during the period of coverage, Honeywell will repair or 
replace, at its option, without charge those items that Honeywell, 
in its sole discretion, finds defective. 

The foregoing is buyer’s 

sole remedy and is in lieu of all other warranties, expressed 
or implied, including those of merchantability and fitness for 
a particular purpose. In no event shall Honeywell be liable for 
consequential, special, or indirect damages.

While Honeywell may provide application assistance personally, 
through our literature and the Honeywell web site, it is buyer’s 
sole responsibility to determine the suitability of the product in 
the application.

Specifications may change without notice. The information we 
supply is believed to be accurate and reliable as of this writing. 
However, Honeywell assumes no responsibility for its use.

Honeywell serves its customers through a worldwide network of 
sales offices, representatives and distributors. For application 
assistance, current specifications, pricing or name of the nearest 
Authorized Distributor, contact your local sales office or:

E-mail: [email protected]
Internet: sensing.honeywell.com
Phone and Fax: 
USA/Canada  

+1-800-537-6945

International  

+1-815-235-6847; +1-815-235-6545 Fax

    

 

WARNING

PERSONAL INJURY

DO NOT USE these products as safety or emergency stop 
devices or in any other application where failure of the product 
could result in personal injury.

Failure to comply with these instructions could result in 
death or serious injury.

Содержание PX3 Series

Страница 1: ...tep change in pressure Turn on time4 7 ms EMC rating5 surge immunity all leads electrostatic discharge radiated immunity fast transient burst immunity to conducted disturbances radiated emissions radiated immunity 1000 V line to ground per IEC 61000 4 5 4 kV contact 8 kV air per IEC 61000 4 2 10 V m 80 MHz to 1000 MHz per IEC 61000 4 3 1 kV per IEC 61000 4 4 3 V per IEC 61000 4 6 40 dB 30 MHz to 2...

Страница 2: ...t zero pressure in order to mini mize measurement error over temperature The output is calibrated to be proportional to the difference between applied pressure and a reference of 1 standard atmosphere 1 013 barA 14 7 psiA Example 100 psi sealed gage has a calibrated pressure range from 14 7 psi absolute to 114 7 psi absolute 1 Sealed gage option only available in pressure ranges at or above 8 bar ...

Страница 3: ... to 257 F 1 Honeywell can assist with selecting suitable seal material for the media based on the seal manufacturer s recommendation The customer should test the compatibility with the media to ensure that it is correct for the application CAUTION PRODUCT DAMAGE Ensure torque specifications are determined for the specific application Values provided are for reference only Mating materials and thre...

Страница 4: ...ail Diagnostics Mode The PX3 Series diagnostics mode allows the device to indicate when internal or external faults occur If an internal fault occurs the output will rail to the preset lower or upper limit values shown in Figure 3 and Table 6 External faults will result in the sensor s output exceeding those preset limits lower or upper For example if the external sensor ground signal were lost th...

Страница 5: ...e turns from finger tight Weight 35 1 g 1 2 oz N2 1 8 27 NPT Seal Pipe thread Mating geometry ANSI B1 20 1 Installation torque Two to three turns from finger tight Weight 31 2 g 1 1 oz T1 Tube Seal Brazing Weight 32 g 1 1 oz ø17 0 0 67 ø21 60 0 85 ø15 9 0 63 12 2 0 48 15 4 0 61 37 4 1 47 49 6 1 95 7 16 20 UNF 1 4 in 45 Flare Female Schrader SAE J512 35 9 1 41 13 9 0 55 11 2 0 44 1 85 47 1 ø17 0 0 ...

Страница 6: ...ree turns from finger tight Weight 70 g 2 5 oz N2 1 8 27 NPT Seal Pipe thread Mating geometry ANSI B1 20 1 Installation torque Two to three turns from finger tight Weight 66 g 2 3 oz T1 Tube Seal Brazing Weight 67 g 2 4 oz ø21 6 0 85 1000 50 39 9 1 9 13 9 0 55 11 2 0 44 31 6 1 24 42 75 1 683 G1 4 A G ISO 1179 3 44 1 1 73 13 5 0 53 ø21 6 0 85 30 6 1 20 12 9 0 51 1000 50 39 9 1 9 M12 x 1 5 ISO 6149 ...

Страница 7: ...Honeywell be liable for consequential special or indirect damages While Honeywell may provide application assistance personally through our literature and the Honeywell web site it is buyer s sole responsibility to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of this writing...

Отзывы: