Installing the PRO3200 Two-Reader Module
LED Operation
PRO3200 Two-Reader Module Installation Guide, Document 800-15493
5
LED Operation
The Two-Reader Module uses two onboard LEDs (D1 and D2) to provide status information during
the power-up sequence as well as during normal operation. The Two-Reader Module also uses two
onboard LEDs (D3 and D4) to indicate reader activity.
In addition to the status LEDs, there are six additional relay status LEDs and eight input status LEDs
on board. The input LEDs flash when there is a fault associated with the input. When any relay or input
is energized or ON, its corresponding status LED becomes ON also. The LED remains ON for as long
as the relay is energized.
Table 3:
Onboard LEDs
Mode
LED D1
LED D2
Description
Power-up
sequence
ON
OFF
Start power-up, hardware setup
OFF
ON
Testing RAM
ON
ON
Testing ROM and completing
initialization
FLASH
ON
LED D1 flashes four times after
power-up is completed
Normal
Operation
FLASH
This is the processor heartbeat LED. It
flashes once every second. A short ON
time (~20% duty cycle) indicates the
board is offline or has lost serial
communication with the Controller
board. A long ON time (~80% duty
cycle) indicates the board is online and
communicating with the Controller
board.
FLASH
Flash when there is activity on its Serial
Port.