![Honeywell Prestige THX9321R01 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/honeywell/prestige-thx9321r01/prestige-thx9321r01_system-installation-manual_154270015.webp)
15
Français : voir la page 17 • Español: vea la página 33
Specifications & replacement parts
Operating Ambient Temperature
Thermostat:
32 to 120° F (0 to 48.9° C)
Remote control:
32 to 120° F (0 to 48.9° C)
Outdoor air sensor:
-40 to 140° F (-40 to 60° C)
Operating Relative Humidity
Thermostat:
5% to 90% (non-condensing)
Remote control:
5% to 90% (non-condensing)
Outdoor air sensor:
0% to 100% (condensing)
Physical Dimensions
(height, width, depth)
Thermostat:
3-9/16 x 5-13/16 x 1-1/2 inches (91 x 147 x 38 mm)
Outdoor air sensor:
5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm)
Electrical Ratings
Terminal
Voltage (50/60 Hz)
Max. Current Rating
W
(heating)
18 to 30 VAC
1.00A
Y
(cooling)
18 to 30 VAC
1.00A
G
(fan)
18 to 30 VAC
0.60A
O/B
(changeover)
18 to 30 VAC
0.60A
W2
(heating)
18 to 30 VAC
0.60A
Y2
(cooling)
18 to 30 VAC
0.60A
Aux/E
(Auxiliary)
18 to 30 VAC
1.00A
L
(Output)
18 to 30 VAC
0.60A
K
N/A
N/A
HUM 1
(humidifier)
30 VAC max.
0.50A
HUM 2
(humidifier)
30 VAC max.
0.50A
DHM 1
(dehumidifier)
30 VAC max.
0.50A
DHM 2
(dehumidifier)
30 VAC max.
0.50A
Accessories & Replacement Parts
Item
Part Number
Wireless adapter
THM4000R1000
Remote control
REM5000R1001
Outdoor air sensor
C7089R1013
Cover plate (covers marks left by old thermostats)
50028399-001
Wire saving module